• Title/Summary/Keyword: Coupled Rooms

Search Result 16, Processing Time 0.021 seconds

Room Acoustic Properties of Coupled Rooms Connected by an Aperture in the Steady State Condition (정상상태조건에서의 개구부로 연결된 커플룸의 음향 특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.315-322
    • /
    • 2016
  • Room acoustic properties of coupled rooms connected by an aperture has been analyzed using statistical acoustic model based on the diffused sound field assumption, which has limitation in dealing with the parameters such an room geometries and non uniform absorptivity of the boundary surfaces. In order to overcome these difficulties the acoustic diffusion model has been introduced, by which distribution of the acoustic energy density can be analyzed for various shapes and wall absorptivity. In this study acoustic properties of coupled rooms connected by an aperture(e.g. door) is analyzed using acoustic diffusion equation, which is solved numerically. The mean energy densities of two rooms obtained by the diffusion model are compared with those from the statistical model. The results show good agreement for various coupling aperture sizes and absorption coefficients. For a limiting case when the partition wall is substituted by an aperture and the two rooms eventually forms a single room, results of coupled room analysis using diffusion model show good agreement with those of a single room.

Parents' Privacy Attitudes towards Children's Rooms of the Urban Housing (도시주거 자녀실에서의 프라이버시 행태 연구 - 부모의 태도를 중심으로 -)

  • 김순경
    • Journal of the Korean housing association
    • /
    • v.3 no.2
    • /
    • pp.43-50
    • /
    • 1992
  • In the course of modernization coupled with urbanization, children's rooms of Korean urban housing has emerged as a symbol of evolution of people's dwelling standards. At the same time. family member's privacy-oriented needs in the home environment have shown its usefulness in the quality of life to some extent. The authors made an analysis of the parents' privacy behavior in relation to the children's rooms, through 1)parents' access rule, and 2)their intervention including goods as a measure. The results are as following: 1)Between knocking behavior a]eng wi th call ins by names of their children (or clearing throat) and non-knocking behavior. there proved to be difference in the parents' attitudes towards access to the children's rooms. The difference is made mainly by the children's age, sex and the exclusiveness of children's rooms. 2)The degree of intervention within children's roms by peopel and goods is observde to be different significantly according to children's age, but not significantly to children's sex and exclusiveness of children's rooms.

  • PDF

Acoustic Properties of Three-room Coupled System by Connected Two Apertures (개구부로 연결된 3중 커플룸의 음향특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

An Indoor Broadcasting System Using Light-Emitting Diode Lamps Coupled with Power Line

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.342-347
    • /
    • 2015
  • We introduce an indoor broadcasting system using light-emitting diode (LED) lamps coupled with a 220 V power line. Two couplers connected to the power line constitute a power line communication (PLC) link. The transmission path from an LED lamp to a photodetector forms a visible light communication (VLC) link in free space. When the LED lamp is coupled to the power line, a composite PLC-VLC link is formed, making it possible to transmit a VLC signal beyond line-of-sight. In experiments, a 4 kHz analog signal modulated with a 100 kHz carrier was sent to the power line by a PLC coupler, and LED lamps coupled to the power line detected the signal and radiated it to multiple VLC receivers in the room. This configuration is useful in expanding an indoor VLC sensor network to adjacent rooms or constructing a voice broadcasting system in a building or apartments with existing power lines.

A Study on the Reverberation Characteristics of Coupled Spaces (음향적으로 결합된 공간의 잔향특성변화에 관한 연구)

  • Jeong, Dae-Up;Kim, Ji-Young;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.3
    • /
    • pp.53-63
    • /
    • 2008
  • In this study, the reverberation characteristics of coupled spaces were investigated using a scale model. Two rooms were connected through an acoustically transparent opening known as an aperture. The acoustic characteristics of the coupled room by varying three parameters, the aperture opening size, the absorption ratio between the two rooms and the locations of the secondary room, were measured and analysed. The results indicated that a reverberant secondary room, produced large variations of the acoustics in the main room and an absorptive secondary room was effective to provide systematic control of the acoustics in the main room. The reverberant secondary room should be located at the rear of the stage and the aperture opening ratio over 6.25% produced large variations of the acoustics in the main room. However, the aperture opening ratio over 25% had no effect on variations of the acoustics in the main room. The absorptive secondary room should be located at the rear of the audience areas and the aperture opening ratio over 3.13% produced large variations of the acoustics in the main room.

  • PDF

Vibro-acoustic Analysis of Adjoined Two Rooms Using 3-D Power Flow Finite Element Method (3차원 파워흐름유한요소법을 이용한 인접한 두 실내에서의 진동음향 해석)

  • Kim, Sung-Hee;Hong, Suk-Yoon;Kil, Hyun-Gwon;Song, Jee-Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.74-82
    • /
    • 2010
  • Power flow analysis(PFA) methods have shown many advantages in noise predictions and vibration analysis in medium-to-high frequency ranges. Applying the finite element technique to PFA has produced power flow finite element method(PFFEM) that can be effectively used for analysis of vibration of complicated structures. PFADS(power flow analysis design system) based on PFFEM as the vibration analysis program has been developed for vibration predictions and analysis of coupled structural systems. In this paper, to improve the function of vibro-acoustic coupled analysis in PFADS, the PFFEM has been extended for analysis of the interior noise problems in the vibro-acoustic fully coupled systems. The vibro-acoustic fully coupled PFFEM formulation based on energy coupled relations is extended to structural system model by using appropriate modifications to structural-structural, structural-acoustic and acoustic-acoustic joint matrices. It has been applied to prediction of the interior noise in two room model coupled with panels, and the PFFEM results are compared to those of statistical energy analysis(SEA).

Research on Vibro-acoustic Coupled Analysis using Power Flow Finite Element Method (파워흐름유한요소법을 이용한 진동음향 연성해석 연구)

  • Kim, Sung-Hee;Kwon, Hyun-Wung;Hong, Suk-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.767-770
    • /
    • 2006
  • To predict vibrational energy density of simple structural-acoustic coupled systems in medium-to-high frequency ranges, Power Flow Finite Element Method(PFFEM) is used, and PFFEM sofiware, PFADS has been developed for the vibration predictions and analysis of coupled system structures in medium-to-high frequency ranges. However, it needs to consider vibro-acoustic coupled analysis to get more accurate results. Prior to implement vibro-acoustic coupled analysis functions in PFADS, research on vibro-acoustic coupled analysis using PFFEH is performed for simple models. These predictions include the indirect transmission path associated, and also the direct transmission path, and the formulation is extended to structural system model by using appropriate modifications to structural-acoustic and acoustic-acoustic joint matrices. Concerning the waves in plate and acoustic, it is possible to calculate the structural-acoustic full matrix of a model using PFFEM, and the formulations developed are implemented for two rooms surrounded by plates.

  • PDF

A Study on the Optimazation of the Hotel Room Rate Pricing Policy (호텔 객실가격정책(客室價格政策)의 합리화(合理化)에 관한 연구(硏究))

  • Han, Seung-Yeop
    • Korean Business Review
    • /
    • v.6
    • /
    • pp.135-152
    • /
    • 1993
  • The optional market segmentation pricing policy for rooms of hotels are investigated under the assumption of a linear demand function, and for four different situations: (1) single price market, (2) optimal segmentation of the unused capacity of a single-price-maeket, (3) optimal segmantation for all rooms, and (4) opimal segmentation for infiltration from higher priced to adjacent lower priced segments. The purpose of tis study is th show that with proper pricing policy, it would be possible to increase profits considerably. Such a profit increase might be achived by market segmentation coupled with product differentiation, where the different market segments are identified, sperated, and in each segment a different price per room is called for. The different prices are determined based on the specific price elasticity typical for each market segment and the relavant costs. The pricing model implied in this study is based on basic economic pricing theory and optimization techniques. While somewhat complex in its mathmatical solution, it can be easily programmed for use by practitioners, avoiding the need to cope with the technical aspects of the solution. In section II-1, the optimal single-market Single-price policy is evaluated. The optimal strategy under the constraint that only the previously unutilized rooms are segmented is analysed in section II-2, while the optimal strategy without this constraint is determined in section II-3. In section II-4, the optimal market-segmentation pricing policy is derived for the case in which market seperation is allowed for all the rooms under the assumption of custtomer infiltration from each market segment to the adjacent lower priced segment Finally, some considerations relating to the practicality of the model as a decision support tool and the requirements for its implementation are discussed in section III.

  • PDF

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.

Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory (생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석)

  • Hwang, Ji Hyun;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.