• Title/Summary/Keyword: Coupled Room

Search Result 121, Processing Time 0.033 seconds

Application of Si3N4 Thin Film as a Humidity Protection Layer for Organic Light Emitting Diode (Si3N4 박막의 유기발광소자 수분침투 방지막으로의 응용)

  • Kim, Chang-Jo;Shin, Paik-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.397-402
    • /
    • 2010
  • In this paper, we studied WVTR(water vapor transmission rate) properties of $Si_3N_4$ thin film that was deposited using TCP-CVD (transformer coupled plasma chemical vapor deposition) method for the possibility of OLED(organic light emitting diode) encapsulation. Considering the conventional OLED processing temperature limit of below $80^{\circ}C$, the $Si_3N_4$ thin films were deposited at room temperature. The $Si_3N_4$ thin films were prepared with the process conditions: $SiH_4$ and $N_2$, as reactive gases; working pressure below 15 mTorr; RF power for TCP below 500 W. Through MOCON test for WVTR, we analyzed water vapor permeation per day. We obtained that WVTR property below 6~0.05 gm/$m^2$/day at process conditions. The best preparation condition for $Si_3N_4$ thin film to get the best WVTR property of 0.05 gm/$m^2$/day were $SiH_4:N_2$ gas flow rate of 10:200 sccm, working pressure of 10 mTorr, working distance of 70 mm, TCP power of 500 W and film thickness of 200 nm. respectively. The proposed results indicates that the $Si_3N_4$ thin film could replace metal or glass as encapsulation for flexible OLED.

A Study on the Prediction of Teeth Deformation of the Automobile Transmission Part(Shaft/Gear) in Warm Shrink Fitting Process (온간압입공정에서 자동차 변속기 단품(축/기어) 치형 변화 예측에 관한 연구)

  • Kim, Ho-Yoon;Choi, Chang-Jin;Bae, Won-Byong;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.54-60
    • /
    • 2006
  • Fitting process carried out in automobile transmission assembly line is classified into three classes; heat fitting, press fitting, and their combined fitting. Heat fitting is a method that heats gear to a suitable range under the tempering temperature and squeezes it toward the outer diameter of shaft. Its stress depends on the yield strength of gear. Press fitting is a method that generally squeezes gear toward that of shaft at room temperature by press. Another method heats warmly gear and safely squeezes it toward that of shaft. Warm shrink fitting process for automobile transmission part is now gradually increased, but the parts (shaft/gear) assembled by this process produced dimensional changes of gear profile in both radial and circumferential directions. So that it may cause noise and vibration between gears. In order to solve these problems, we need an analysis of warm shrink fitting process, in which design parameters are involved; contact pressure according to fitting interference between outer diameter of shaft and inner diameter of gear, fitting temperature, and profile tolerance of gear. In this study, an closed form equation to predict contact pressure and fitting load was proposed in order to develop optimization technique of warm shrink fitting process and verified its reliability through the experimental results measured in the field and FEM, that is, thermal-structural coupled field analysis. Actual loads measured in the field have a good agreement with the results obtained by theoretical and finite element analysis and also the expanded amounts of the gear profile in both radial and circumferential directions are within the limit tolerances used in the field.

Influence of Coating Defect Ratio on Tribological Behavior Determined by Electrochemical Techniques (전기화학적 분석을 통해 산출된 코팅 결함율이 트라이볼로지적 특성에 미치는 영향 평가)

  • Lee Young-Ze;Kim Woo-Jung;Ahn Seung-Ho;Kim Ho-Gun;Kim Jung-Gu;Cho Chung-Woo
    • Tribology and Lubricants
    • /
    • v.20 no.6
    • /
    • pp.306-313
    • /
    • 2004
  • Many of the current development in surface modification engineering are focused on multilayered coatings, which have the potential to improve the tribological properties. Four different multilayered coatings were deposited on AISI D2 steel in this study. The prepared samples are designed as $WC-Ti_{0.6}Al_{0.4}N,\;WC-Ti_{0.53}Al_{0.47}N,\;WC-Ti_{0.5}Al_{0.5}N\;and\;WC-Ti_{0.43}Al_{0.57}N$. The multilayered coatings were investigated with respect to coating surface and cross-sectional morphology, roughness, adhesion, hardness, porosity and tribological behaviors. Especially, wear tests of four multilayered coatings were performed by using a ball-on-disc configuration with a linear sliding speed of 0.017 m/sec and a normal load of 5.38 N load. The tests were carried out at room temperature in air by employing AISI 52100 steel ball $(H_R\;=\;66) $ having a diameter of 10 mm. The surface morphology, and topography of the wear scars of samples and balls have been determined by using scanning electron spectroscopy (SEM). Also, wear mechanism was determined by using SEM coupled with energy-dispersive spectroscopy (EDS). Results have showed an improved wear resistance of the $WC-Ti_{1-x}Al_xN$coatings with increasing of Al (aluminum) concentration.

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

Dwelling Characteristics of Geese Families based on the Analysis of Sleeping and Studying Patterns in Vancouver (자녀의 취침 및 학습 행위 패턴으로 본 기러기 가족의 주생활 특성 연구 - 캐나다 밴쿠버 지역의 조기 유학생 가정을 대상으로 -)

  • Lee, Hyun-Hee
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.3
    • /
    • pp.365-377
    • /
    • 2010
  • This study examined the changes in sleeping and studying patterns of young students and their mothers after moving to foreign countries. This study analyzed the relational characteristics of Geese Family members which are summarized as follows: 1) Sleeping Pattern: At the early stages of settling into foreign countries, students begin to sleep in the same bedroom with their mothers, who had used to sleep in separate bedrooms back in Korea. This change in pattern may slightly vary according to the age and gender of the students, and type of residence. Relationships between young students and mothers become more tightly coupled. However, relationships between students and fathers become less tightened. 2) Studying Pattern: Students tend to study in the public space such as the living room and dining areas, rather than in their own private rooms. This is because mothers want to support and focus upon their children's study by sacrificing normal family activities. These patterns appear stronger as their period of study in the foreign country becomes shorter and the ages of the students become younger. These studying patterns also contribute to the coupling between mothers and young students. 3) Family Relationships: From the period as Geese Families, the relation between mothers and young students become closer both physically and emotionally. The relation between fathers and children become less close. The role of fathers is degraded to that of supporter or negotiator for the time period of the mothers and child students in the foreign country.

Development of Optimization Technique of Warm Shrink Fitting Process for Automobile Transmission Part(Shaft/Gear) (자동차 변속기 단품(축/기어)용 온간압입공정 최적화 기법 개발)

  • Kim Ho-Yoon;Bae Won-Byong;Kim Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.37-43
    • /
    • 2006
  • Fitting process carried out in automobile transmission assembly line is classified into three classes; heat fitting, press fitting, and their combined fitting. Heat fitting is a method that heats gear to a suitable range under the tempering temperature and squeezes it toward the outer diameter of shaft. Its stress depends on the yield strength of gear. Press fitting is a method that generally squeezes gear toward that of shaft at room temperature by press. Another method heats warmly gear and safely squeezes it toward that of shaft. Warm shrink fitting process for automobile transmission part is now gradually increased, but the parts (shaft/gear) assembled by this process produced dimensional change in both outer diameter and profile of the gear. So that it may cause noise and vibration between gears. In order to solve these problems, we need an analysis of warm shrink fitting process, in which design parameters are involved; contact pressure according to fitting interference between outer diameter of shaft and inner diameter of gear, fitting temperature, and profile tolerance of gear. In this study, an closed form equation to predict contact pressure and fitting load was proposed in order to develop optimization technique of warm shrink fitting process and verified its reliability through the experimental results measured in the field and FEM, that is, thermal-structural coupled field analysis. Actual loads measured in the field have a good agreement with the results obtained by theoretical and finite element analysis and also the expanded amounts of the outer diameters of the gears have a good agreement with results.

Analysis of the Warm Shrink Fitting Process for Assembling the Part(Shaft and Output Gear) (단품(축/OUTPUT 기어)조립을 위한 온간압입공정 해석)

  • Kim, Tae-Jin;Kang, Hee-Jun;Kim, Chul;Chu, Suck-Jae;Kim, Ho-Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.47-54
    • /
    • 2008
  • Fitting process carried out in the automobile transmission assembly line is classified into three classes; heat fitting, press fitting, and their combined fitting. Heat fitting is a method that heats gear to a suitable range under the tempering temperature and squeezes it toward the outer diameter of shaft. Its stress depends on the yield strength of gear. Press fitting is a method that generally squeezes gear toward that of shaft at room temperature by a press. Another method heats warmly gear and safely squeezes it toward that of shaft. Warm shrink fitting process for the automobile transmission part is now gradually increased, but the parts (shaft/gear) assembled by this process produced dimensional changes in both the outer diameter and profile of the gear. So that it may cause noise and vibration between gears. In order to solve these problems, we need an analysis of warm shrink fitting process, in which design parameters are involved; contact pressure according to fitting interference between outer diameter of shaft and inner diameter of gear, fitting temperature, and profile tolerance of gear. In this study, an closed form equation to predict contact pressure and fitting load was proposed in order to develop an optimization technique of the warm shrink fitting process and verified its reliability through the experimental results measured in the field and FEM, that is, thermal-structural coupled field analysis. Actual loads measured in the field was in good agreements with the results obtained by the theoretical and finite element analysis.

Study for Recovery Silicon and Tempered Glass from Waste PV Modules (태양전지(太陽電池) 폐(廢) 모듈로부터 실리콘 및 강화(彈化)유리 회수(回收)에 관(關)한 연구(硏究))

  • Kang, Suk-Min;Yoo, Sung-Yeol;Lee, Jin-A;Boo, Bong-Hyun;Ryu, Ho-Jin
    • Resources Recycling
    • /
    • v.20 no.2
    • /
    • pp.45-53
    • /
    • 2011
  • We devised a procedure for the recovery of silicon and tempered glass from waste photovoltaic (PV) modules using optimized conditions. The tempered glass was recovered without any damage using organic solvents. The surface material is removed by applying an acid solution on the surface of the PV cell. Through our proposed method, we offer a much more efficient approach for recycling solar cells with a surfactant than the conventional method. This process, we obtained pure silicon with a yield of 90% by chemical treatment with the surfactant at room temperature for 18 min. The silicon yield was characterized using an inductively coupled plasma-atomic emission spectrometer.

Identification and Characterization of Phytochemicals from Peanut (Arachis hypogaea L.) Pods

  • Lee, Jin-Hwan;Baek, In-Youl;Ha, Tae-Joung;Choung, Myoung-Gun;Ko, Jong-Min;Oh, Sea-Kwan;Kim, Hyun-Tae;Ryu, Hyung-Won;Park, Keum-Yong;Park, Ki-Hun
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.475-482
    • /
    • 2008
  • Methanol extracts of peanut (Arachis hypogaea L.) pods were chromatographed, which yielded 3 phytochemicals 1-3 including 5,7-dihydroxychromone (1), eriodictyol (2), and 3',4',5,7-tetrahydroxyflavone (3). To confirm the presence of isolated phytochemicals, the pods extracts were performed by high performance liquid chromatography coupled with a photodiode array detector (HPLC-PDA) and a mass spectrometric detector (MSD) with electrospray ionization (ESI). Optimum extraction conditions for phytochemical contents using peanut germplasm were obtained by employing 90% MeOH for 12 hr at room temperature and phytochemicals 1-3 showed significant differences with concentrations of $407.56{\pm}23.35$, $52.92{\pm}5.11$, and $2,024.34{\pm}134.18\;{\mu}g/g$, respectively. Under this optimal conditions, the contents of phytochemicals 1-3 in peanut pods of 3 Korea cultivars including 'Jakwang', 'Daekwang', and 'Palkwang' exhibited phytochemical 3 was the highest range of $1,338.01-5,162.93\;{\mu}g/g$, followed by phytochemical 1 ($590.13-1,382.10\;{\mu}g/g$), and phytochemical 2 ($25.12-186.85\;{\mu}g/g$), respectively. Moreover, 'Jakwang' exhibited the highest contents of phytochemical (1: $1,362.10{\pm}52.49$, 2: $186.85{\pm}17.69$, and 3: $5,162.93{\pm}148.64\;{\mu}g/g$, respectively), whereas the lowest contents was found in the 'Daekwang' (1: $590.13{\pm}22.23$, 2: $25.12{\pm}2.45$, and 3: $1,338.01{\pm}62.17\;{\mu}g/g$, respectively). These results suggest that the methanol extracts of peanut pods may possess health related benefits to humans owing to various known biological activities of phytochemicals 1-3.

Validation of ICP-MS method for trace level analysis of Pb in plasma (혈장 중 극미량 납 분석을 위한 ICP-MS 분석법 검증)

  • Lee, Sung-Bae;Kim, Yong-Soon;Lee, Yong-Hoon;Ahn, Byung-Joon;Kim, Nam-Soo;Lee, Byung-Kook;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.309-316
    • /
    • 2015
  • The analytical method of lead in plasma by ICP-MS was validated after securing environment within class 1,000 classification. We tested specificity and accuracy of within-run and between-run. According to measurement of the amount of suspended particulates in a clean room, 0.3~62 particles were detected in 0.3 µm size while 0.0~28.3 particles were observed in 0.5 µm size. Total suspended particulates met required environment with up to 90.3 particles. The MDL (Method detection limit) of the sample which has been fabricated using fetal bovine serum (FBS) blank was 1.77 ng/L, and LOQ (Limit of quantification) was 5.55 ng/L. The slope, intercept and correlation coefficient of the calibration curve were y=1.09×10−3x+4.88×10−2 and r=0.9999, which showed good correlation. The specificity, within-run and between-run accuracy satisfied the standard at more than 50 ng/L. The average lead concentration in plasma of the general people, current workers and retired workers was 55.4 ng/L, 440 ng/L, and 132 ng/L.