• 제목/요약/키워드: Coupled Cavity

검색결과 133건 처리시간 0.025초

EFFECTS OF PHASE-LAGS AND VARIABLE THERMAL CONDUCTIVITY IN A THERMOVISCOELASTIC SOLID WITH A CYLINDRICAL CAVITY

  • Zenkour, Ashraf M.
    • 호남수학학술지
    • /
    • 제38권3호
    • /
    • pp.435-454
    • /
    • 2016
  • This paper investigates the effect of dual-phase-lags on a thermoviscoelastic orthotropic solid with a cylindrical cavity. The cylindrical cavity is subjected to a thermal shock varying heat and its material is taken to be of Kelvin-Voigt type. The phase-lag thermoelastic model, Lord and Shulman's model and the coupled thermoelasticity model are employed to study the thermomechanical coupling, thermal and mechanical relaxation (viscous) effects. Numerical solutions for temperature, displacement and thermal stresses are obtained by using the method of Laplace transforms. Numerical results are plotted to illustrate the effect phase-lags, viscoelasticity, and the variability thermal conductivity parameter on the studied fields. The variations of all field quantities in the context of dual-phase-lags and coupled thermoelasticity models follow similar trends while the Lord and Shulman's model may be different. The influence of viscosity parameter and variability of thermal conductivity is very pronounced on temperature and thermal stresses of the thermoviscoelastic solids.

Aperture와 Feedline Gap 결합으로 급전되는 마이크로스트립 패치 안테나의 전자기 결합 메커니즘 (Electromagnetic Coupling Mechanism in the Aperture-Coupled and Feedline Gap-Coupled Microstrip Patch Antenna)

  • 김종규;윤이근;조영기
    • 대한전자공학회논문지TC
    • /
    • 제38권1호
    • /
    • pp.27-33
    • /
    • 2001
  • 개구결합으로 급전되는 마이크로스트립 안테나 구조에 대해, 접지면과 패치사이의 간격에 따라 ‘cavity'형과 ’parasitic'형의 두 가지 결합 메커니즘으로 나눌 수 있음을 이론적, 실험적으로 제시하였으며, 보다 단순한 급진구조로서 gap-결합 급전 마이크로스트립 안테나구조에서도 유사한 현상이 나타남을 확인하였다. 이러한 두 가지 결합메커니즘의 특징적 차이에 대하여 논의하였다.

  • PDF

이중 대역 개구면 결합 공진기 급전 마이크로스트립 안테나 설계 (Dual Band Design of Aperture-Coupled Cavity-Fed Microstrip Antenna)

  • 장국현;남경민;이장환;남상호;김철언;김정필
    • 대한전자공학회논문지TC
    • /
    • 제44권3호
    • /
    • pp.26-32
    • /
    • 2007
  • 개구면 결합 공진기 급전 마이크로스트립 패치 안테나의 단순하고도 정확한 등가 회로를 추출한다. 이 등가회로는 이상적인 트랜스포머, 어드미턴스 소자, 그리고 전송선으로 구성되고 각 소자 값들은 가역 정리와 스펙트럼 영역 이미턴스 방법에 기반한 복소 전력 개념으로부터 구할 수 있다. 기 게재된 논문의 연구 결과를 이용하여 제안한 등가회로의 타당성을 검증한 후 이중 대역 안테나를 유전 알고리즘과 Holder-Mead 방법을 통한 이종 진화적 최적화 방법으로 설계하였다. 설계 목표치에 적합한 결과를 도출하였고, 이 결과는 이종 진화적 최적화 방법이 설계에 매우 효율직임을 확인해 준다.

개구면 결합 공진기 급전 마이크로스트립 패치 안테나의 회로망 해석 및 설계 (Network Analysis and Design of Aperture-Coupled Cavity-Fed Microstrip Patch Antenna)

  • 신종우;김정필
    • 대한전자공학회논문지TC
    • /
    • 제41권12호
    • /
    • pp.93-102
    • /
    • 2004
  • 본 논문은 개구면 결합 공진기 급전 마이크로스트립 패치 안테나에 대하여 간결하면서도 정확한 등가회로 모델을 추출하기 위한 일반적인 전자기 이론을 제안하였다. 그리고 등가회로는 이상적인 트랜스, 어드미턴스, 그리고 전송선으로 구성된다. 관련소자들의 값은 복소전력 개념, Fourier 변환, Fourier 급수, 그리고 spectral-domain immittance-approach를 적용하여 계산된다. 본 논문에서는 이 방법을 이용하여 안테나의 입력 임피던스를 구하고, 기존 논문에서 발표된 계산값, 그리고 측정값들과 비교하였다. 기존의 연구 결과와의 정확한 일치는 본 논문이 제안한 등가회로 모델의 간결성과 정확성을 입증해 준다.

직육면체 캐비티의 다중 모드 특성및 표면파 모드 특성 측정 (Measurements of multimode characteristics including surface wave mode in a dielectrically loaded rectangular cavity)

  • 김채영;김윤명;라정웅
    • 전기의세계
    • /
    • 제28권4호
    • /
    • pp.47-52
    • /
    • 1979
  • Total number of resonant modes in a microwave oven cavity may be maximized for a given frequency bandwidth to obtain more uniform power distribution by choosing proper size of the cavity. The total number of modes is calculated for a dielectrically loaded rectangular cavity and its size is suggested here for which the change in the number of modes is less sensitive to the change of dielectric layer thickness and its total number of modes is maximized in a given range of cavity sizes. A prove coupled rectangular cavity is constructed and the total existing modes are measured to see the change of modes depending on the dielectric layer thickness and the cavity size. Surface wave mode existing in the dielectric layer is confirmed by measuring Q and the input impedance of the cavity for this mode, which closely compares with the calculation.

  • PDF

Second order grating CCGSE-DFB 레이저 해석 (Concentric-Circle-Grating Surface Emitting (CCGSE)-DFB Laser with second order grating)

  • 박해령;김효창;이연호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.313-316
    • /
    • 2000
  • Concentric-Circle-Grating (CCG) cavity is analyzed by coupled mode theory. In this case concentric grating is acting as both feedback element and output coupler. In our calculations radiation loss terms are included in guided coupled mode equations. The surface-emitted field distribution is obtained in self-consistent manner.

  • PDF

개구 결합 마이크로스트립 안테나 구조에서의 필드 분포 (Field Configurations in Aperture-Coupled Microstrip Antenna Structure)

  • 조영기;고지환;이영순;허유강
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.259-262
    • /
    • 2002
  • The problems of electromagnetic coupling and radiation in an aperture-coupled microstrip antenna structure are discussed while focusing on the difference between two representative field configuration: parasitic-type and cavity-type. Based on the discussion, a critical look is taken at the validity of a previous description of the coupling mechanism of m aperture-coupled microstrip antenna.

  • PDF

산란행렬에 의한 2단자망 RF 공동공진기의 Q 측정 (Q measurement of two port RE cavity by scattering parameters)

  • 한대현
    • 한국정보통신학회논문지
    • /
    • 제4권4호
    • /
    • pp.895-899
    • /
    • 2000
  • 산란행렬을 이용하여 2단자망 RF 공동공진기의 Q 측정 방법을 제안하였다. 집중소자를 이 용한 등가회로 모델을 이용하여 공동공진기의 Q를 포함한 파라미터의 함수로 산란행렬을 구했다. 산란행렬은 회로망분석기를 이용하여 직접 측정할 수 있다. 제안한 방법으로 측정한 결과는 기존에 잘 알려진 방법과 일치함을 보였다. 제안한 방법의 Q 측정 절차는 기존의 방법에 비해서 간단할 뿐만 아니라 RF 공동공진기가 전자빔을 가속시킬 때 중요한 파라미터인 결합전력비를 구할 수도 있다.

  • PDF

공동 스퀴즈 필름 댐퍼에 지지된 회전체의 정상상태 응답 해석 (Steady State Respknse of a Rotor Supported on Cavitated Squeeze Film Dampers)

  • 정시영;정재천;심상규
    • 소음진동
    • /
    • 제2권3호
    • /
    • pp.213-222
    • /
    • 1992
  • The effect of cavitation on the synchronous steady state response of a single rotor supported on cavitated squeeze film dampers executing a circular orbit is investigated theoretically. The Swift-Stieber boundary conditions and a long bearing approximation are utillized to evaluate the direct and the cross coupled damping coefficients of a cavitated squeeze film damper. For typical design parameters, frequency response curves are presented here to exhibit the effect of cavitation on the imbalance response and transmissibilities for both a flexible rotor and a rigid rotor. Investigations show that cavitation occured in a squeeze film damper produces bistable jump phenomena and deteriorates the performance of a squeeze film damper. This arises from that the large cavity causes substantial increment of the cross coupled damping which has radial stiffening effect. Furthermore, the large cavity causes the decrement of the direct damping which has pure damping effect. It is also observed that in the absence of cavitation, both rotor excursion amplitude and imbalance transmissibilities are very well damped.

  • PDF

표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정 (Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration)

  • 권휴상;서상준;서재갑;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF