• Title/Summary/Keyword: Coupled Building Control

Search Result 46, Processing Time 0.022 seconds

Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment (벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가)

  • Ju, Young Kyu;Kim, Dae Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.765-772
    • /
    • 2002
  • Many researchers have studied several vibration control devices such as TMD, TLD, and VED to reduce the acceleration level for tall buildings. Advantages of TLD (tuned liquid damper) include easy installation, low cost, and less maintenance. However, the dynamic characteristics of TLD must be verified by experiment and analysis due to the difficulties in evaluating the characteristics of water sloshing. In this study, free vibration and dynamic excitation experiments of structure with TLD were conducted to verify vibration control force of the proposed TLD for high-rise building. The parameters were mass ratio of water to structure, number of damping nets, and aspect ratio. From the test results, the responses of structure with water tank were observed to be smaller than those of structure alone. Furthermore, better damping effect could be achieved with larger mass ratio, more damping nets, and larger aspect ratio. However, in the case of water tank with no damping net, little damping effect was obtained.

Evaluation on Structural Performance of Two-nodal Rotary Frictional Component (2절점 회전형 마찰요소의 구조성능 평가)

  • Kim, Do-Hyun;Kim, Ji-Young;Kim, Myeong-Han
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.51-57
    • /
    • 2015
  • Various hybrid dampers have been developed in Korea to control the vibration due to a wind and earthquake. In order to minimize the installment space, cost and construction process, the new hybrid friction damper is developed. This hybrid damper is composed of several rotary friction components having two frictional joint. Because of these components, the building vibration due to wind and earthquake can be mitigated by hybrid friction damper. In this paper, various dependency tests were carried out to evaluate on the structural performance of two joint rotational friction component of the hybrid damper. Test results show that two joint rotational components do not depend on a displacement and a frequency of forcing but friction coefficients is reducing as a clamping force is increasing.

A Design of Data Repository for Software Maintenance Tools (소프트웨어 유지보수 도구를 위한 자료 저장소의 설계)

  • Choe, Eun-Man
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 1995
  • It has been commonly accepted for a while that a successful tool environment must provide for smooth interfaces between its tools. Recent integrated CASE environment must be-based on well-integrated data repository which supports a tightly coupled, consistent environment. For the maintenance tool, it requires a careful design of the maintenance chest's database. Information about a program exists in many different forms after analyses have been performed. It must be possible to associate and select objects for data repository from this information as necessary. This paper suggests a new integrated scheme for the data repository in building software maintenancec environment. The scheme provides many basic services, including storage and management of objects/entities and links/ relations; version and configuration control, query service, data interchange service.

  • PDF

Modification of MUSCL Scheme for Application of Non-uniform Grid (비정형격자의 적용을 위한 MUSCL 기법의 수정)

  • Kim, Byung-Hyun;Han, Kun-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.1
    • /
    • pp.105-117
    • /
    • 2010
  • This paper presents a new and simple technique to perform MUSCL reconstruction for solving 2D shallow water equations. The modified MUSCL scheme uses weighted area ratio to apply non-uniform grid in stead of the previous method that equally distributed the difference of conservation variables to each interface. The suggested method can physically reconstruct conservation variables in case of uniform grid as well as non-uniform grid. In this study, Unsplit scheme applicable to unstructured grid is used and efficient slope limiter of TVD scheme is used to control numerical oscillation which can be occurred in modified MUSCL scheme. For accurate and efficient treatment of bed slope term, the modified MUSCL scheme is coupled with the surface gradient method. The finite volume model applied to suggested scheme is verified through a comparison between numerical solution and laboratory measurements data such as the simulations of isolated building test case and Bellos's dam break test case.

Experimental Study of Coupled Shearwalls with different Coupling Member (인방보의 형태에 따른 개구부가 있는 전단벽의 거동 특성에 대한 실험적 연구)

  • Bae, Baek-Il;Choi, Hyun-Ki;Choi, Yoon-Chel;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.37-40
    • /
    • 2008
  • Many engineers find the way of improving the old building's structural behavior in the remodeling project which is performed using artificial openings for merging two houses. This test was performed to verify the characteristics of coupling beams according to the shape of the openings. One of test specimen has rectangle shape and the other was made by the circle shaped opening and one has coupling member only as slabs. Additionally, three specimens which have openings have 23% ratio in opening area to total wall area. Consequently, solid type which have no opening area shows shear failure. In the case of CW-RBS which have rectangular shaped opening, cracks are developed in coupling beam significantly. And CW-CS which has circular opening failed in shear showing development of diagonal cracks at wall toes and wall mid-height. It is thought that degradation of the wall strength is under the control of the opening shape and coupling beam-wall connection area.

  • PDF

RSM-based Practical Optimum Design of TMD for Control of Structural Response Considering Weighted Multiple Objectives (가중 다목적성을 고려한 구조물 응답 제어용 TMD의 RSM 기반 실용적 최적 설계)

  • Do, Jeongyun;Guk, Seongoh;Kim, Dookie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.113-125
    • /
    • 2017
  • In spite of bulk literature about the tuning of TMD, the effectiveness of TMD in reducing the seismic response of engineering structures is still in a row. This paper deals with the optimum tuning parameters of a passive TMD and simulated on MATLAB with a ten-story numerical shear building. A weighted multi-objective optimization method based on computer experiment consisting of coupled with central composite design(CCD) central composite design and response surface methodology(RSM) was applied to find out the optimum tuning parameters of TMD. After the optimization, the so-conceived TMD turns out to be optimal with respect to the specific seismic event, hence allowing for an optimum reduction in seismic response. The method was employed on above structure by assuming first the El Centro seismic input as a sort of benchmark excitation, and then additional recent strong-motion earthquakes. It is found that the RSM based weighted multi-objective optimized damper improves frequency responses and root mean square displacements of the structure without TMD by 31.6% and 82.3% under El Centro earthquake, respectively, and has an equal or higher performance than the conventionally designed dampers with respect to frequency responses and root mean square displacements and when applied to earthquakes.