• Title/Summary/Keyword: Counting System

Search Result 442, Processing Time 0.024 seconds

Measurement of Absorption and Scattering Coefficients of Biological Tissues by Time-Resolved Reflectance Method (시간 분해 반사율에 의한 생체조직의 흡수계수와 산란계수 측정)

  • Jeon, Kye-Jin;Park, Seung-Han;Kim, Ung;Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.499-505
    • /
    • 1997
  • A non-invasive technique to measure absorption and scattering coefficients was investigated The reflected backscattered light from the surface of phantom and biological tissue was obtained by using a time-correlated single photon counting system in pico-second time domain. The absorption and scattering coefficients were acquired by the time of peak and asymptotic behavior of the time-resolved reflectance curve and agreed well the ones that is obtained with deconvolution method It was found that the approximation method was good for biological medium to calculate optical properties due to its convenience and accuracy.

  • PDF

Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry

  • Park, Chanwoo;Song, Hankyeol;Joung, Jinhun;Kim, Yongkwon;Kim, Kyu Bom;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2346-2352
    • /
    • 2020
  • Dual-energy x-ray absorptiometry (DXA) is the noninvasive method to diagnose osteoporosis disease characterized by low bone mass and deterioration of bone tissue. Many global companies and research groups have developed the various DXA detectors using a direct photon-counting detector such as a cadmium zinc telluride (CZT) sensor. However, this approach using CZT sensor has some drawback such as the limitation of scalability by high cost and the loss of efficiency due to the requirement of a thin detector. In this study, a SiPM based DXA system was developed and its performance evaluated experimentally. The DXA detector was composed of a SiPM sensor coupled with a single LYSO scintillation crystal (3 × 3 × 2 ㎣). The prototype DXA detector was mounted on the dedicated front-end circuit consisting of a voltage-sensitive preamplifier, pulse shaping amplifier and constant fraction discriminator (CFD) circuit. The SiPM based DXA detector showed the 34% (at 59 keV) energy resolution with good BMD accuracy. The proposed SiPM based DXA detector showed the performance comparable to the conventional DXA detector based on CZT.

The Research for Remote-indicating Magnetic Compass(I) (원격지시식 자기 compass 에 관한 연구(I))

  • 이상집;임정빈
    • Journal of the Korean Institute of Navigation
    • /
    • v.10 no.1
    • /
    • pp.81-100
    • /
    • 1986
  • Self-contained portable remote-indicating magnetic compass was designed and tested. Its sensing part consists of main scale disk of rotary encoder with photo-etched 180, oopaque slits and three pairs of light sources and detectors seperated by a transparent index scale, so that any angular deflection of main scale disk against the bowl may be detected optically. The outputs from the sensing part are transformed into digital ship's course indication by electronics unit which consists of operational amplifier, phase discriminator, up-down counter and counting starter circuit. The results from testign the above compass with turntable at variable rate of turn are as following : 1) The main scale disk deflection against the bowl can be detected without any disturbing influence to the freedom of its north-seeking function. 2) The digital indication resolution is found to be $\circ \pm$1 degree. 3) Misrepresenting indication can be avoided by ensuring dimension uniformity and arrangement accuracy of slits on main and index scale disks and by centering pivot in the encoder disk. 4) Indication resolution should be improved by modifying the signal processing and by doubling the number of slits on compass card. 5) Further study should be made on developing non-conductive compass liquid, analogue repeater driving system and more compact processing element.

  • PDF

Strain and Temperature Measurement using Transmission-type EFPI Optical Fiber Sensors (투과형 EFPI 광섬유 센서를 이용한 변형률 및 온도의 측정)

  • Kim, Sang-Hoon;Lee, Jung-Ju;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The extrinsic Fabry-Perot interferometric (EFPI) optical fiber sensor shows good sensitivity and resolution, and has many advantages over optical fiber sensors of other types. However, this EFPI optical fiber sensor has a disadvantage that the distinction of measuring directions is difficult due to the measurement method by using only fringe counting. In this paper, the transmission-type extrinsic Fabry-Perot interferometric (TEFPI) optical fiber sensor was developed, which has been improved by the additional function and whose measuring system is different from that of the conventional EFPI optical fiber sensor. Then the application result of the TEFPI optical fiber sensor to the strain and temperature measurement was explained in detail.

  • PDF

A Stochastic Differential Equation Model for Software Reliability Assessment and Its Goodness-of-Fit

  • Shigeru Yamada;Akio Nishigaki;Kim, Mitsuhiro ura
    • International Journal of Reliability and Applications
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Many software reliability growth models (SRGM's) based on a nonhomogeneous Poisson process (NHPP) have been proposed by many researchers. Most of the SRGM's which have been proposed up to the present treat the event of software fault-detection in the testing and operational phases as a counting process. However, if the size of the software system is large, the number of software faults detected during the testing phase becomes large, and the change of the number of faults which are detected and removed through debugging activities becomes sufficiently small compared with the initial fault content at the beginning of the testing phase. Therefore, in such a situation, we can model the software fault-detection process as a stochastic process with a continuous state space. In this paper, we propose a new software reliability growth model describing the fault-detection process by applying a mathematical technique of stochastic differential equations of an Ito type. We also compare our model with the existing SRGM's in terms of goodness-of-fit for actual data sets.

  • PDF

A Study on the Riser Fatigue Analysis Using a Quarter-modal Spectrum (사봉형 스펙트럼을 이용한 라이저 피로해석 연구)

  • Kim, Sang Woo;Lee, Seung Jae;Choi, Sol Mi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.514-520
    • /
    • 2016
  • Oil and gas production riser systems need to be designed considering a wide band quarter-modal analysis which contains low-, wave-, VIV(Vortex induced vibration) frequencies. The VIV can be separated into cross-flow(CF) and in-line(IL) components. In this study, the various idealized tri- and quarter-modal spectra are suggested to analyze fatigue damage on the production riser system. In order to evaluate the fatigue damage increment caused by the IL's motion, tri- and quarter-modal spectral fatigue damages are calculated in time domain. And the fatigue damage calculated from two different modal spectra are compared quantitatively. Then the suitability of existent wide band fatigue damage models for quarter modal spectrum was evaluated by comparison of frequency domain calculation and time domain calculation. The result show that although spectral density of IL motion is not remarkable in quantity, the effect on the fatigue damage is significant and existent fatigue damage models are not adequately estimating damage by quarter-modal spectra.

Composition and Analysis of Linear Component Counting based Multiple Indexing (직선성분 계수 기반 다중 인덱싱 구성 및 분석)

  • Park, Je-Ho;Lim, Sang-Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.17-21
    • /
    • 2010
  • As the compact and easily accessible handheld devices, such as cellular phones and MP3 players equipped with image acquisition functionality, are becoming widely available among common users, various applications of images are rapidly increasing. Image related services and software such as web-based image presentation and image manipulation for personal or commercial purpose enable users to view contents of remote image archive and to manipulate enormous amount of images in local or network based storage as well. It is necessary for users to identify the images efficiently so that the same images are perceived as one physical entity instead of recognizing them as different images as the trends are getting stronger. In order to support this environment, we propose a method that generates image identifiers or indexing for images within a solid and efficient manner. The proposed image identifier utilizes multiple index values. The integration of component index values creates a unique composite value that can be used as a file name, file system identifier, or database index. Our experimental results on generation of constituent index values have shown favorable results.

Dimmable Spatial Intensity Modulation for Visible-light Communication: Capacity Analysis and Practical Design

  • Kim, Byung Wook;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.532-539
    • /
    • 2018
  • Multiple LED arrays can be utilized in visible-light communication (VLC) to improve communication efficiency, while maintaining smart illumination functionality through dimming control. This paper proposes a modulation scheme called "Spatial Intensity Modulation" (SIM), where the effective number of turned-on LEDs is employed for data modulation and dimming control in VLC systems. Unlike the conventional pulse-amplitude modulation (PAM), symbol intensity levels are not determined by the amplitude levels of a VLC signal from each LED, but by counting the number of turned-on LEDs, illuminating with a single amplitude level. Because the intensity of a SIM symbol and the target dimming level are determined solely in the spatial domain, the problems of conventional PAM-based VLC and related MIMO VLC schemes, such as unstable dimming control, non uniform illumination functionality, and burdens of channel prediction, can be solved. By varying the number and formation of turned-on LEDs around the target dimming level in time, the proposed SIM scheme guarantees homogeneous illumination over a target area. An analysis of the dimming capacity, which is the achievable communication rate under the target dimming level in VLC, is provided by deriving the turn-on probability to maximize the entropy of the SIM-based VLC system. In addition, a practical design of dimmable SIM scheme applying the multilevel inverse source coding (MISC) method is proposed. The simulation results under a range of parameters provide baseline data to verify the performance of the proposed dimmable SIM scheme and applications in real systems.

High sensitivity determination of iridium contents in ultra-basic rocks by INAA with coincidence gamma-ray detection

  • Ebihara, Mitsuru;Shirai, Naoki;Kuwayama, Jin;Toh, Yosuke
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.423-428
    • /
    • 2022
  • Very low contents (in the range of 10-9 g/g) of Ir in mantle-derived rock samples (komatiites) were non-destructively determined by INAA coupled with coincidence gamma-ray spectrometry using 16 Ge detectors. Aliquots of the same samples were analyzed by NiS fire-assay ICP-MS for Ir and other platinum group elements. Because the INAA procedure used in this study is non-destructive and is almost free from spectral interference in gamma-ray spectrometry, the INAA values of Ir contents obtained in this study can be highly reliable. Iridium values obtained by ICP-MS were consistent with the INAA values, implying that the ICP-MS values of Ir obtained in this study are equally reliable. Under the present experimental conditions, detection limits were estimated to be 1 pg/g, which corresponds to 0.1 pg for a sample mass of 0.1 g. These levels can be even lowered by an order of magnitude, if necessary, which cannot be achieved by ICP-MS carried out in this study.

Studies on the Maintenance of Bioluminescence from Stored Photobacterium phosphoreum (Photobacterium phosphoreum의 생체발광 유지도에 관한 연구)

  • 김현숙;정성제;전억한
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.2
    • /
    • pp.117-123
    • /
    • 2000
  • The object of this work is to improve the maintenance of bioluminescence from stored Photobacterium phosphoreum in a view of developing continuous monitoring system for pollutants. The long-term experiments were performed to determine the effect of storage temperature and immobilization on the maintenance of bioluminescence and viability of P. phosphoreum. A naturally luminescent bacterium, P. phosphoreum was starved in 2.5% Nael solution at $20^{\circ}C$, $4^{\circ}C$, -$20^{\circ}C$ and -$70^{\circ}C$ for 30 days. In vivo luminescence was measured by luminometry, and total cell concentrations and concentrations of culturable and viable cells were determined by acridine orange staining, dilution plate counting, and direct viable counting, respectively. The bioluminescence emission from cells stored at 4De was maintained up to 10 days while those with starved cells at other temperature ranges decreased to background level within 3 days. In terms of viability of cells, concentrations of cells stored at $20^{\circ}C$ were rapidly decreased as a result of cell lysis, leading to a drop in culturable and viable counts while cells stored at $4^{\circ}C$ was shown viable but nonculturable state during starvation. With immobilized cells on strontium alginate, the bioluminescence showed higher maintenance than free cells and decreased with count number of nonculturable cells.

  • PDF