• Title/Summary/Keyword: Counter ion

Search Result 166, Processing Time 0.025 seconds

The Effect of Iron Catalysts on the Formation of Alcohol and Ketone in the Biomimetic Oxidation of Cyclohexane

  • Kim Seong-Bo;Lee Kyu-Wan;Kim, Yong-Joon;Hong Seog-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.424-427
    • /
    • 1994
  • Effects of iron compounds in known biomimetic oxidation systems (Gif IV and GoAgg II) have been studied on activity and ketone/alcohol selectivity of cyclohexane oxidation. Both ketone/alcohol ratio and cyclohexane conversion were affected by counter-ion Z of iron compounds Z-Fe. When Z has a more electron withdrawing property, the reactivity is increased and the formation of ketone is favored. From these experimental results, a new mechanism is proposed for the biomimetic oxidation system.

Novel Synthesis of Hydrophilic Dipolar Chromophores using Dendronized Sulfonates

  • Kim, Mi-Rae;Maheswara, Muchchintala;Do, Jung-Yun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.664-672
    • /
    • 2011
  • A series of hydrophilic chromophores was synthesized through introduction of dendritic sulfonate anions using click chemistry. A dendron structure bearing several sulfonate groups enhances hydrophilicity of attached chromophores. A click triazole formation connects chromophores with hydrophilic groups. A neutral trichloroethyl sulfonate has versatile features such as easy introduction, chemical endurance for isolation or storage, and convenient transformation to a hydrophilic anion. Zinc and OH mediated cleavage of trichloroethyl group from the neutral sulfonate undergoes to generate a water-soluble sulfonate anion. The solubility was examined with different counter cations and in different pH media and thus increased with the number of attached sulfonate ion. Two hydrophilic chromophores of stilbene-derived and azobenzene-derived dipolar structures exhibit clear negative and positive solvatochromism in protic solvents, respectively.

CrN and TiN Coatings for the Wear Resistance of Extrusion Mold for Magnesium (마그네슘 압출용 금형의 내마모성 향상을 위한 CrN, TiN 코팅)

  • Lee, Su-Young;Kim, Sang-Ho
    • Journal of Surface Science and Engineering
    • /
    • v.44 no.6
    • /
    • pp.233-238
    • /
    • 2011
  • The friction and wear characteristics of CrN and TiN coatings on SKD61 which is mold material using for extrusion of AZ80 magnesium alloy were investigated. The coatings were deposited by the arc ion-plating method, and the thickness were about $3.59{\mu}m$ and $3.28{\mu}m$, respectively. Reciprocating friction wear tests were conducted by varying pin load and temperature of counter substrate at un-lubricated condition. The pin loads were 11, 15 and 19 kgf, and the substrate temperatures were room temperature and $120^{\circ}C$. CrN coating which has a lower friction coefficient and a smaller adhesive wear with AZ80 magnesium alloy showed better wear resistance than TiN coating.

Electrochemical Diagnosis of Magnesium Ion in Fish Liver and Mice Droppings

  • Lee, Chang-Hyun;Ly, Suw Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.663-668
    • /
    • 2014
  • An in-vivo diagnosis of trace Mg(II) ion was performed using a low-cost and environment-friendly voltammetric method, using a graphite counter and reference electrodes and a fluorine-immobilized graphite working electrode, and clean deep seawater was used as an electrolyte solution. Under optimum conditions, the analytical working ranges attained microgram ranges, and a detection limit of $80.6ugL^{-1}$ was obtained using stripping voltammety with 60 sec accumulation time. Ex-vivo application was performed on fish liver and mice droppings. The developed techniques can be applicable to tumor cell analysis.

Characteristics of N-and P-Channel FETs Fabricated with Twin-Well Structure (Twin-well 구조로 제작된 N채널 및 P채널 FET의 특성)

  • 김동석;이철인;서용진;김태형;김창일;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.86-90
    • /
    • 1992
  • We have studied the characteristics of n-and p-channel FETs with submicron channel length fabricated by twin-well process. Threshold voltage variation and potential distribution with channel ion implantation conditions and impurity profile of n-and p-channel region wee simulated using SUPREM-II and MINIMOS 4.0 simulater, P-channel FET had buried-channel in the depth of 0.15 $\mu\textrm{m}$ from surface by counter-doped boron ion implantation for threshold voltage adjustment. As a result of device measurement, we have obtained good drain saturation characteristics for 3.3 [V] opreation, minimized short channel effect with threshold voltage shift below 0.2[V], high punchthrough and breakdown voltage above 10[V] and low subthreshold value.

  • PDF

Analysis of Germanium in the Ore Samples by UV-Visible Spectroscopy

  • Reddy, K. Raghava;Lee, Kwang-Pill;Gopalan, Anantha Iyengar;Showkat, Ali Md;Kim, Sang-Ho;Paek, U-Hyon
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.476-480
    • /
    • 2004
  • A simple, rapid, reproducible and selective UV-Visible spectrophotometric method has been developed for determination of germanium in a week acid medium (pH = 3.0) in the presence of mandelic acid (MA) and malachite green (MG). A single extraction in chlorobenzene was used for the analysis. The germanium-MA ion association complex exhibits an absorption maximum at ${\lambda}_{max}=618nm$ with MG as counter ion and has an apparent molar absorptivtity of $1.313{\times}10^5L\;mol^{-1}\;cm^{-1}$. The values obtained by this UV-Visible spectrophotometric method are in good agreement with the values from inductively coupled plasma-mass spectrometer analysis.

Isotopic Analysis of NUSIMEP-6 Uranium Particles using SEM-TIMS

  • Park, Jong-Ho;Park, Sujin;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.51-54
    • /
    • 2013
  • Isotopic analysis using thermal ionization mass spectrometry coupled with scanning electron microscopy (SEM-TIMS) was performed to determine the isotopic ratios of uranium contained in micro-particles in the 6th Nuclear Signatures Interlaboratory Measurement Evaluation Programme (NUSIMEP-6) sample. Elemental analysis by energy dispersive X-ray spectroscopy (EDS) was conducted on uranium-bearing mirco-particles, which were transferred to rhenium filaments for TIMS loading using a micromanipulation system in a SEM. A multi-ion-counter system was utilized to detect the ion signals of the four isotopes of uranium simultaneously. The isotope ratios of uranium corrected by bracketing using a reference material showed excellent agreement with the certified values. The measurement accuracy for $n(^{234}U)/n(^{238}U)$ and (b) $n(^{235}U)/n(^{238}U)$ was 10% and 1%, respectively, which met the requirements for qalification for the NetWork of Analytical Laboratories (NWAL).

Alignment and lattice quality of hexagonal rings of hexagonal BN films synthesized by ion beam assisted deposition (이온빔보조증착법으로 합성한 hexagonal BN막의 hexagonal ring의 배열과 결정성)

  • 박영준;한준희;이정용;백영준
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • We have studied the alignment and the lattice quality of hexagonal rings of h-BN films synthesized by ion beam assisted deposition (IBAD) method. Boron was e-beam evaporated at 1.5 $\AA$/sec and nitrogen gas was ionized using end-hall type ion gun at 60, 80, and 100 eV, respectively. Substrate was either not heated or heated at 200, 400, 500, and $800^{\circ}C$, respectively. As nitrogen ion energy increases, c-axes of hexagonal rings tend to align parallel to the substrate, which is explained by larger compressive stress at higher ion energies. Alignment of c-axis increases with temperature and shows maximum around $400^{\circ}C$. The lattice quality of hexagonal rings improves with temperature. Such behaviors can be understood from two counter trends of increasing the atomic mobility and decreasing compressive stress with temperature. Hardness of h-BN films shows the same trend with the alignment of c-axis. Ion beam assisted deposition method seems to be effective for aligning hexagonal rings and optimizing h-BN properties.

  • PDF