• Title/Summary/Keyword: Cost-saving

Search Result 1,315, Processing Time 0.024 seconds

Effects of Printed-Saving Coupon on Purchasing Intention of Consumer Behavior in Major Discount Store (대형 할인 마트의 인쇄 쿠폰 발행이 소비자 구매 의도에 미치는 영향)

  • Lee, Kwang-Sook;Kwak, Bo-Sun
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.1
    • /
    • pp.21-33
    • /
    • 2012
  • This research attempts to analyze the effect of printed-saving coupons distributed by major discount store on consumer purchasing intention. Those consumers having used printed-saving coupon in major discount store in Daejeon were selected as respondents. 121 copies were retreated from 150 questionnaires. For data analysis, frequency analysis for respondents' characteristics, Cronbach's alpha for reliability of analysis, and $X^2$ test of multi-regression analysis for testing hypothesis were utilized. The result of analysis shows 1) the way of using coupon is respectively different according to sex, age group, marital status, term of coupon, and the number of using coupon; 2) Attributes of coupon partially influence on purchasing intention of consumers. Only shopping cost cutting is insignificant, while keeping convenience, impulse buying, scheduled purchasing are significant. The most effective variable is scheduled purchasing, keeping convenience, and impulse buying influence on purchasing intension of consumers. Therefore, offering printed-coupon by major discount store is useful tool to induce consumers to planned purchasing.

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

A Study on the Perfomance Analysis of Low Energy Cooling Systems in Office building (사무소건물의 에너지절약형 냉방시스템 성능분석에 관한 연구)

  • Park, Chang-Bong;Rhee, Eon-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.89-94
    • /
    • 2010
  • A large portion of the energy cost of a building is cooling and heating to maintain a comfortable indoor environment. Air conditioning is now one of the important parts in the building design, as increase in energy consumption and pollutant emission in energy conversion process. In this study, elements that affects the energy consumption of model building are identified and the perfomance analysis of the alternative a Low Energy Cooling Systems considering characteristics of model building and energy saving performance is analyzed. In this study, elements that affect the energy consumption of office building are identified and energy saving performance of the alternative air conditioning system is analyzed. As a result, applied to earn and suggest basic data for energy saving measures. In this study, EnergyPlus simulation program was used to evaluate the energy load when alternative Low Energy Cooling Systems are applied to the model building. The reliability of simulation program is verified by comparing actual energy load from operation data of building management office and predicted energy load using simulation program. For Low Energy Cooling System application which considers the purpose and characteristics of the building, reasonable and energy-saving air conditioning method obtained by analyzing energy consumption elements for each expected air conditioning methods is used to deduct result of this study.

Energy Saving Effect and Improvement of Indoor Thermal Environment through the Window Retrofit (창호 리트로피트를 통한 에너지 절감 및 실내 열환경 개선 효과 분석에 관한 연구)

  • Jeong, Jin-Woo;Ju, Jung-Hoon;Cho, Dong-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.3
    • /
    • pp.29-36
    • /
    • 2018
  • The goal of this study is to retrofit the windows of residential buildings and to activate the green remodeling by verifying energy saving and indoor thermal environment. As a result of analysis of the energy saving effect of 458 units window retrofits, it was possible to reduce the energy requirement by 48.20% ~ 54.97%. According to the improvement on indoor environment, it was possible to operate by reducing heating temperature and supply time. The actual gas consumption of the heating period was reduced by 25% compared with that of the window retarder to save 28,968 thousand won of heating energy cost. Resident's satisfaction surveys were conducted one year after window retrofit. More than 80% of the respondents answered that they satisfied the improvement on window performance, indoor thermal environment and indoor sound environment. As a result, we verified the energy saving effect and the improvement on the indoor environment through window retrofits.

An Empirical Study on the Spin-Off into Internet Business - Emphasis on Factors, Expected Benefits, Strategies - (인터넷 비즈니스 사업으로의 효과적인 스핀오프에 관한 실증연구 - 유발요인, 기대효익, 전략을 중심으로 -)

  • Lee, Kun-Chang;Chung, Nam-Ho;Ahn, Kwang-Mi
    • Asia pacific journal of information systems
    • /
    • v.12 no.3
    • /
    • pp.213-233
    • /
    • 2002
  • Recently, a lot of companies intend to make spin-offs as the Internet usage is proliferating in the business area. A spin-off means a small but autonomous company which is thought to show higher profitability rather than it stays under the influence of a mother enterprise. To prove our hypotheses, we collected questionnaire data from 104 companies considering spin-offs. From experiments with Factor Analysis, we found that there exist four factors which decision-makers should consider before deciding spin-offs such as competence of unit, competence of mother company, competence of spin-off company, and support of mother company. After massive experiments with Regression Analysis we also found that there are significant three performance factors such as competence of unit, competence of spin-off company, and support of mother company. The survey also asked about three potential strategies that they may have been following for achieving business objectives: Cost leadership, Focus, and Differentiation, Six benefits factors emerged from this study: External competitiveness, Internal competency, Productivity, Change, Cost saving, and Improvement. External competitiveness was the most important benefit, and it predicted a Differentiation and Focus strategy. Productivity and Improvement also predicted a Differentiation strategy. External competitiveness, Change, and Cost saving predicted a Cost leadership strategy. However, organizations followed Differentiation and Focus strategies significantly more than Cost leadership. The assessment thus sheds light on the link between information strategy and spin off. We hope that based on our results, many companies considering a spin-off can make a right decision and expect higher performance in a turbulent business environment.

A Study on an Estimation of Optimum Rice Farm Size (수작농가(水稻作農家)의 적정영농규모계측(適正營農規模計測)에 관(關)한 연구(硏究) -강원도 철원군 평야지역 농가를 중심으로-)

  • Kim, Jong-Pil;Lim, Jae-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.81-94
    • /
    • 2005
  • This study is aimed at giving the basic information for individual farm households to make decisions for optimizing their farm sizes and for the government to implement farm size optimization policies through the identification of combinations among rice production factors in plain areas like Cheolwon district and the suggestion of the optimal farm sizes of individual farmers based on the scale of economy calculated. The data of agricultural production costs of 50 rice farmers in the plain area which is located in Dongsong-eup Cholwon district, Kangwon province were used in the analysis. The 'translog' cost function among various methods which is a flexible function type was adopted to calculate the scale of economy in rice production. Seemingly unrelated regression(SUR) method was used in forecasting functions and processing other statistics by SHAZAM which is one of the computer aid program for quantitative econometric analysis. In conclusion, the long-run average cost(LAC) curve showed 'U-shape' which was different from 'L-type' one which was shown in the previous studies by others. The lowest point of the LAC was 9.764ha and the concerned production cost amounted to 633 Won/kg. Based on these results, it have to be suggested that around 10 ha of paddy is the target size for policy assistances to save costs under the present level of farming practices and technology. The above results show that the rice production costs could be saved up to 10ha in Cheolwon plain area which is a typical paddy field. However, land use, land condition, land ownership and manager's ability which may affect scale of economy should be considered. Furthermore, reasonable management will have to be realized by means of labor saving technology and cost saving management skill like enlargement of farm size of rice.

  • PDF

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

The Performance Evaluation and The Layout Improvement of the Engine Manufacturing Line Using Simulation (시뮬레이션을 사용한 엔진생산라인의 성능평가 및 설계개선)

  • 오필범
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.224-228
    • /
    • 1999
  • When we construct a manufacturing plant, optimal design is very important. This paper is to simulate an engine manufacturing flow line for commercial vehicle. The parameters we consider in simulation include facility downtime, tool change time, buffer size between consecutive stations, and time to repair the facility. We use AutoMod to compare the alternatives. The objective is to minimize the total cost. Simulation results provide significant cost saving by improving the current design and policy.

  • PDF

The Study on Successful Logistical Relationships in Third-Party Provider (제3자 물류기업의 성공적인 물류관계성에 관한 연구)

  • Jung, Chae Hoon;Her, Jun
    • Journal of Industrial Convergence
    • /
    • v.5 no.1
    • /
    • pp.103-119
    • /
    • 2007
  • It is very important for the logistics business success that Third-Party Provider maintains a successful logistical relationship with customers. The important factors for the successful logistical relationship are customer orientation, service timeliness, reciprocal dependability, keeping long-term relationships, and logistics cost savings. Therefore, Third-Party Provider establishes the logistics strategy based on the reciprocal dependability with customers and the long-term of view. In addition, the logistics strategy provides the logistics services satisfying customers and saving logistics cost.

  • PDF

Comparative Evaluation between Cool Roof and Green Roof in terms of Installation Cost: a Case Study of KNU Campus (설비 투자비용의 관점에서 쿨루프와 옥상녹화의 비교 평가: 경북대학교 캠퍼스 사례를 중심으로)

  • Kim, Jun-Woo;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.927-939
    • /
    • 2012
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. Although green roof has already gained nation-wide recognition as a typical method of energy saving in the roof, this approach did not provide a realistic evidence that is economically feasible in terms of installation cost. This research is primarily intended to compare installation cost between the two techniques. This research proposes a comparative evaluation framework in a more objective and quantitative way for an installation cost between the two techniques. Kyungpook National University (KNU) was selected as a survey objective and an exhaustive and realistic comparison of installation cost between the two techniques was conducted, based on Life Cycle Cost analysis (initial investment cost, maintenance cost, dismantling and waste disposal expense). It was possible to identify that installation cost of cool roofs is 4.7 times cheaper than that of green roof. Also present value based on probabilistic approach was identified as 0.25 (4.95) higher than the installation cost on the assumption of constant price and interest. It is expected that much more installation cost for the large scale green roof will be required since small-size green roof selected as a survey objective in this study could be operated under less initial installation and maintenance condition.