• 제목/요약/키워드: Corrosive water management

검색결과 11건 처리시간 0.025초

상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황 (The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America)

  • 김민희;현승훈;이원석
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

금속용사 방식공법의 경제성 평가에 관한 연구 (A Study on the Economic Evaluation of Thermal Spray Methods for the Corrosion Protection of Steel)

  • 정성호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.13-16
    • /
    • 2005
  • Generally, as corrosive protection processing of a steel structure, zinc galvanizing and heavy duty coating paint are applied. However, zinc galvanizing has the difficulty of restriction of a size, or on-site construction. Moreover, heavy duty coating paint has a problem with many administrative and maintenance expenses with short problem of adhesion, corrosion generating of a damage portion, and maintenance management cycle. In this study, a salt water spray test, CASS test, and the electrochemistry examination were carried out for the thermal metal spray method of construction for corrosive protection performance evaluation. Moreover, the corrosive protection life of a thermal metal spray method of construction was quantitatively calculated on the basis of this experiment. in consideration of LCC, the economical efficiency of a general corrosive protection method of construction and a thermal metal corrosive protection method of construction was compared. Consequently, although initial construction expense was estimated 16 to $30\%$ high, as for a thermal metal spray method of construction, it turns out that the administrative and maintenance expenses for 100 years became cheap 9.3 to 13 or more times.

  • PDF

정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향 (The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines)

  • 이현동;정해룡;곽필재;정원식
    • 대한환경공학회지
    • /
    • 제22권4호
    • /
    • pp.661-669
    • /
    • 2000
  • 본 연구는 6개 관종으로 구성된 모의순환관로시스템에서 정수의 부식성을 조절하여 관로내의 부식을 저감시킬 목적으로 pH 및 알칼리도 조절 수질제어시스템을 운전하여 관로의 금속용출 저감 및 부식성 지수의 변화를 파악하고, 수질제어에 따른 다른 수질인자들 즉, 미생물, 잔류염소농도, 그리고 소독부산물(THMs) 및 이온류 등의 농도 변화를 평가하고자 하였다. 실험결과, pH 및 알칼리도 조절을 통한 수질제어시스템은 부식성 지수의 변화와 함께 금속의 용출율이 감소하였으며, 소독부산물(THMs)의 형성 및 미생물의 재성장에도 별다른 영향을 미치지 않는 것으로 나타나 수질제어에 따라 관 표면에 형성된 탄산칼슘 피막은 부식저감과 함께 관로내 수질의 안정화를 가져오는 것으로 판단된다. 따라서 pH 및 알칼리도 동시 조절을 통한 부식성 수질 제어시스템은 고형물의 침전 및 용출에 가장 큰 영향을 미치는 pH 및 TIC 등 수질인자들을 안정화시켜 전체적인 수돗물의 수질관리에 매우 효과적일 것으로 사료된다.

  • PDF

Subcritical Water Extraction에 의한 PCBs 추출 (Extraction of PCBs by Subcritical Water Extraction)

  • 곽동환;문지용;이성인;정기호
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.511-519
    • /
    • 2000
  • 물은 초임계 상태($T{\geq}374^{\circ}C$, $p{\geq}221$ atm)에서 비극성 유기오염물질에 대해 좋은 용매로 작용 하지만 부식성이 강하게 나타난다. Subcritical water extraction (이하 SWE)은 토양이나 저니토에 흡착되어 있는 비극성 유기오염물을 신속하고 효율적으로 추출할 수 있다. Subcritical 조건 하에 있는 물은 다양한 비극성 유기물들을 추출할 수 있다. SWE를 이용하면 토양이나 저니토로부터 수 분 이내에 PCBs를 완전히 제거할 수 있으며, 50 atm, $260^{\circ}C$의 subcritical 상태에 있는 물을 추출에 이용한다.

  • PDF

국내 수질에 적합한 부식성지수 선정 연구 (Evaluation of Corrosion Index by Water Quality Parameters in Korea)

  • 안경희;유순주;박수정;권오상
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안 (Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems)

  • 서대근;왕창근
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

Classification of Operating State of Screw Decanter using Video-Based Optical Flow and LSTM Classifier

  • Lee, Sang-Hyeop;Wesonga, Sheilla;Park, Jang-Sik
    • 한국산업융합학회 논문집
    • /
    • 제25권2_1호
    • /
    • pp.169-176
    • /
    • 2022
  • Prognostics and health management (PHM) is recently converging throughout the industry, one of the trending issue is to detect abnormal conditions at decanter centrifuge during water treatment facilities. Wastewater treatment operation produces corrosive gas which results failures on attached sensors. This scenario causes frequent sensor replacement and requires highly qualified manager's visual inspection while replacing important parts such as bearings and screws. In this paper, we propose anomaly detection by measuring the vibration of the decanter centrifuge based on the video camera images. Measuring the vibration of the screw decanter by applying the optical flow technique, the amount of movement change of the corresponding pixel is measured and fed into the LST M model. As a result, it is possible to detect the normal/warning/dangerous state based on LSTM classification. In the future work, we aim to gather more abnormal data in order to increase the further accuracy so that it can be utilized in the field of industry.

Characteristics of Non-Point Pollution from Road Surface Runoff

  • Lee, Chun-Sik;Jang, Seong-Ho
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.665-670
    • /
    • 2010
  • Pollutants from urban pavement consists various kinds of substances which are originated from dry deposition, a grind out tire, corrosive action of rain to pavement and facilities and raw materials of the road etc.. These are major pollutants of urban NPS (Non-point source) during rainfall period. However there is not enough information to control such pollutants for appropriate management of natural water quality. In this study of transportation areas, three monitoring stations were set up at trunk road, urban highway and national road in Gyeongnam province. Runoff flow rate was measured at every 15minutes by automatic flow meters installed at the end of storm sewer pipe within the road catchment area for water quality analysis. Data was collected every 15 minutes for initial two hours of rainfall. Additional samples were collected 1-4 hours interval till the end of rainfall. The monitoring parameters were $COD_{Mn}$, SS, T-N & T-P and heavy metals. The average EMCs of TSS and $COD_{Mn}$ were 62.0 mg/L and 24.2 mg/L on the city trunk road, which were higher than those of urban highway and national road, indicating higher pollutant loads due to activities in the city downtown area beside the vehicle. On the other hand, the average EMC of T-N and T-P were in the range of 2.67-3.23 mg/L and 0.19-3.21 mg/L for all the sampling sites. Heavy metals from the roads were mainly Fe, Zn, Cu and Mn, showing variable EMCs by the type of road. From the TSS wash-off analysis in terms of FF(first flush) index, first flush phenomenon was clearly observed in the trunk road(FF : 0.89-1.43). However, such mass delivery behavior was not apparently shown in urban highway(FF : 0.90-1.11) and national road(FF : 0.81-1.41).

관광동굴의 환경친화적 관리 방안에 관한 연구 (Pro-environmental Maintenance and Management of Tour Cave : The Currents, Problems and Alternatives in Korea)

  • 유영준;이경호
    • 동굴
    • /
    • 제59권
    • /
    • pp.21-36
    • /
    • 1999
  • Most scholars calssify caves into natural resource, but caves possess values of natural and human resource, mix up the features of natural resources and human resources. Now, caves are distributed 260 in Korea. Seongryu Cave is showed in 1967 for the first time, till 1997 12 caves is opened to tourist. But since 1996 the 12 show caves of all is not launched the safety and environment-protection check-up adduced reason for IMF. Then caves must maintain environment of the normal temperature, humidity and dark. But the environment of caves are destroyed by tourism development. Thus to maintain environment of caves, it used to consider the counterplan as follows in restraint of the environmental change. Firstly, in case of development work to open caves, it must keep up with the prototype. Secondly, it must establish a freight depositary to prevent the influence of the caves's stain and damage due to tourist's objects. Thirdly, to maintain the normal temperature and humidity, it must install artificial poultice equipment of the inner parts of caves. Fourthly, in order to prevent the occurrence of $CO_2$, it must assessment of the optimum number of the greatest stayer. Fifthly, the control of closure for a given period of time is useful of the restoration to the cave's original state. Sixthly, by means of make narrow entrance, it should not influence the outer's air on the inner parts on caves. Seventhly, to keep the temperature of the inner part of caves, the lightening should be maintained moderately considering the convenience of a tour. Eightly, when water-proof cables for the lightening bulbs are connected each other, silicon tape is suitable and circuit breakers should be installed at the diverging points of the cables. Ninthly, the direction and angle of the lightening must be changed periodically to prevent green-pollution at the lightening spot. Lastly, when facilities and arrangements are equipped, corrosive materials should be excluded if circumstances allow.

  • PDF