• Title/Summary/Keyword: Corrosion deterioration inspection

Search Result 47, Processing Time 0.022 seconds

EWIS Reliability Analysis of Aging Fighter Aircraft through Teardown Inspection (완전분해 점검을 통한 장기운영 전투기 전기배선시스템의 신뢰성분석)

  • Lee, Hoyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.4
    • /
    • pp.116-121
    • /
    • 2018
  • According to the incresement of aging aircraft, Republic of Korea Air Force (RoKAF) conducted a teardown inspection of aircraft's EWIS (electrical wiring interconnection system) to determine the status of deterioration and the influence of failure occurrences due to it. The inspected aircraft were the retired fighter jets that had been used for more than 40 years. By analyzing defect type and the defect tendency, RoKAF can establish the necessary measures for the usage extension of their fleet and furthermore, the analysis results can be used as a basic data for the preparation of it's aircraft aging. EWIS inspection was done throughout careful visual inspection technique by removing all the ducts and pipes located in the fuselage and wings. For the aircraft wiring where no damage was found, the elongation tests were performed to determine the deterioration of wiring according to the location of the aircraft. The connectors, which is the main cause of intermittent failure, were completely disassembled and inspected for internal damage such as corrosion, abrasion, and traces of foreign objects. The detected defects were classified into 4 severity levels based on the type of damage, and the classified defects were weighted according to the criticality which may affects to it's system to establish the action plan.

Progressive Evaluation of Concrete Deterioration Caused by Chloride-Induced Steel Corrosion Using Impact-Echo Testing (충격 반향 신호 모니터링을 통한 철근 부식 진전에 따른 콘크리트 상태 평가)

  • Rizky Pitajeng;Julfikhsan Ahmad Mukhti;Seong-Hoon Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.37-46
    • /
    • 2024
  • This study investigates the evolution of concrete damage due to chloride-induced steel corrosion through Impact-echo (IE) testing. Three reinforced concrete specimens, each measuring 1500 mm in length, 400 mm in width, and 200 mm in thickness, were fabricated using three concrete mixture proportions of blended cement types: ordinary Portland cement, ground granulated blast-furnace slag and fly ash. Steel corrosion in the concrete was accelerated by impressing a 0.5 A current following a 35-day cycle of wet-and-dry saturation in a 3% NaCl solution. Initial IE data collected during the saturation phase showed no significant changes, indicating that moisture had a minimal impact on IE signals and highlighting the slow progress of corrosion under natural conditions. Post-application of current, however, there was a noticeable decline in both IE peak frequency and the P-wave velocity in the concrete as the duration of the impressed current increased. Remarkably, progressive monitoring of IE proves highly effective in capturing the critical features of steel-corrosion induced concrete deterioration, such as the onset of internal damages and the rate of damage propagation. These results demonstrate the potential of progressive IE data monitoring to enhance the reliability of diagnosing and prognosticating the evolution of concrete damage in marine environment.

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.

A Study on Corrosion Potential of Cracked Concrete Beam According to Corrosion Resistance Assessment (부식 저항성 평가에 따른 균열 콘크리트 보의 부식전위 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.97-105
    • /
    • 2009
  • Development and use of blended cement concrete is gaining more importance in the construction industry with reference to durability mainly due to the pore refinement and reduction in permeability. Cracks play a major role on important parameters like permeability, rate of chloride ingress, compressive strength and thus affect the reinforcement corrosion protection. Furthermore, when a crack occurs in the cover concrete, the corrosion of the steel reinforcement may be accelerated because the deterioration causing factors can pass through the crack. In recent years the effect of cracking on the penetration of concrete has been the subject of numerous investigations. Therefore assessing the service life using blended concrete becomes obviously in considering the durability. In the present study, the corrosion assessment of composite concrete beams with and without crack with of 0.3mm using OPC, 30% PFA, 60% GGBS, 10% SF was performed using half cell potential measurement, galvanic potential measurement, mass loss of steel over a period of 60days under marine environmental conditions and the results were discussed in detail.

Evaluation of Durabilities in Ruined RC Bridge (철근콘크리트 철거교량의 내구성 평가)

  • 유환국;김국한;류금성;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.655-658
    • /
    • 1999
  • An experimental investigation on the ruined RC bridge with 30 years old has been conducted to estimate the durabilities. The ruined RC bridge estimated in this study was located at Kyung-Bu Express Way. First, concrete strength and durability characteristics such as concrete resistivity, chloride content were estimated. Second, it was to test reinforcing corrosion embedded in slab of bridge. And, third, tensile strength and yield strength of reinforcing bar corroded and not corroded were estimated. This bridge inspection provides the most common cause of defects and deterioration and the results of this inspections give more specific information than those of laboratory inspections do.

  • PDF

Seismic-performance Flexural Experiments for Real Scale Piers with Circular Cross-section Considering Aging Effects (노후도를 고려한 실크기 원형단면 교각의 내진성능 휨실험)

  • Lee, Seung-Geon;Lee, Soo-Hyung;Lee, Hyerin;Hong, Kee-Jeung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.131-142
    • /
    • 2021
  • For old piers constructed when seismic design code had not been developed, lap splices usually exist in plastic hinge region. Corrosion of rebars causes decreasement in cross-sectional area of rebar and deterioration of lap-splice behaviour, thereby reducing the seismic performance of the old piers. In this research, according to these characteristics of old piers, test specimens are designed and manufactured considering rebar corrosion, lap splice, seismic design details, and seismic reinforcement. These effects are investigated through experiments. As a result of these experiment, rebar corrosion as well as lap splice reduces displacement ductility. When seismic design details or steel-plate reinforcement are applied, sufficient displacement ductility is expressed. For non-seismically designed specimens, loosening of the lap splice of transverse rebars caused buckling of longitudinal rebars and crushing of core concrete in plastic hinge region . For seismically designed specimen, area-reducing and untying of transverse rebars due to corrosion of rebars caused buckling of longitudinal rebars and crushing of core concrete.

Wireless structural health monitoring of bridges: present and future

  • Hoult, Neil A.;Fidler, Paul R.A.;Hill, Peter G.;Middleton, Campbell R.
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.277-290
    • /
    • 2010
  • Internationally the load carrying capacity of bridges is decreasing due to material deterioration while at the same time increasing live loads mean that they are often exposed to stresses for which they were not designed. However there are limited resources available to ensure that these bridges are fit for purpose, meaning that new approaches to bridge maintenance are required that optimize both their service lives as well as maintenance costs. Wireless sensor networks (WSNs) provide a tool that could support such an optimized maintenance program. In many situations WSNs have advantages over conventional wired monitoring systems in terms of installation time and cost. In order to evaluate the potential of these systems two WSNs were installed starting in July 2007 on the Humber Bridge and on a nearby approach bridge. As part of a corrosion prevention strategy, a relative humidity and temperature monitoring system was installed in the north anchorage chambers of the main suspension bridge where the main cables of the bridge are anchored into the foundation. This system allows the Bridgemaster to check whether the maximum relative humidity threshold, above which corrosion of the steel wires might occur, is not crossed. A second WSN which monitors aspects of deterioration on a reinforced concrete bridge located on the approach to the main suspension bridge was also installed. Though both systems have provided useful data to the owners, there are still challenges that must be overcome in terms of monitoring corrosion of steel, measuring live loading and data management before WSNs can become an effective tool for bridge managers.

Condition Evaluation of Bare Concrete Bridge Decks (콘크리트 노출 교량 바닥판의 상태평가 기법)

  • Suh, Jin-Won;Rhee, JI-Young;Seo, Sang-Gil;Shin, Jae-In
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • In 1980's, the concrete bridge decks were constructed with 4cm wearing surface layer instead of asphalt concrete overlays. After about 15 year service periods, deteriorations were appeared on the surfaces of highway bridge decks. Various field NDTs and lab tests were done to analysis the cause of the deterioration on the concrete deck surface. The main cause was the corrosion of rebars with thinner concrete top cover than the design value. The rebars with thinner concrete top cover was earlier corroded by penetrated chloride ions. If the appropriate top cover could be achieved, the bare concrete bridge decks can be used without earlier deteriorations.

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.