• Title/Summary/Keyword: Corrosion Protection Current

Search Result 175, Processing Time 0.028 seconds

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

An Experimental Study on the Application of Cathodic Protection By Applying Zn-Al Metal Spray to an RC Structure (철근콘크리트 구조물에 Zn-Al 금속용사 전기방식 공법의 적용성에 관한 실험적 연구)

  • Han, Man-Hae;Yoo, Jo-Hyeong;Lim, Young-Chul;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.21-29
    • /
    • 2010
  • Cathodic Protection has been introduced as a method of protecting metals under the ground or sea from corrosion. Since 1970, it has been applied to reinforced concrete structures as a corrosion protection method. After 1990, it became used around the world, and its usability has been well confirmed. But this method has some problems in terms of construction and economy. To solve these problems, a Cathodic Protection Method using a highly-durable metal spray was developed. First, the specimen was covered with anodic materials (Zn, Al) by using metal spray. The corrosion protection performance was confirmed by measuring the corrosion current of the specimen. Through the experiment, it is possible to confirm that the Cathodic Protection Method using a high metal spray provides effective protection against corrosion to reinforced concrete structures.

Polarization Characteristics of Thermal Sprayed Coating Layer (용사코팅층의 분극특성)

  • Ahn, S.H.;Kim, S.J.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.4
    • /
    • pp.38-43
    • /
    • 2004
  • Thermal spraying onto the metal substrate has been widely used as a technique of the surface treatment in the various industrial field. A wide range of thermal spray technologies exist and all rely on the fundamental process of fusing a metal feedstock, atomizing it and transporting it to the surface of a substrate. Specially, these methods have been taken into account as the protection method against the corrosion. In this study, the polarization characteristics were carried out on the thermal sprayed coating layer immersed in various pH of diluted aqueous solutions at $25^{\circ}C$. Aluminum, Zinc, Ni-base alloy, alumina and polyethylene powder were used with sprayed coating materials. From the polarization curves, the electrochemical corrosion potential($E_{corr}$) and the corrosion current density($I_{corr}$) were investigated.

  • PDF

Lifetime of Insoluble Anode for Cathodic Protection on Concrete Construction

  • Sohn, Kicheon;Chang, Hyunyoung;Kim, Youngsik
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.56-59
    • /
    • 2005
  • In rebar concrete structure, the corrosion of rebar can arise the deterioration of concrete structure and may affect the safety of the whole system. Recently, several methods for corrosion protection have been used and are more important for concrete structure using the sand including chloride ion. Among several protections, electrical cathodic protection has been expected to be one of the most useful methods in corrosion protection for reinforcement of concrete structures. The anode for cathodic protection needs high current density, high corrosion resistance and low overvoltage. To fill up the special qualities, the insoluble anodes were developed and these anodes were coated with metal oxide of $TiO_2$, $ZrO_2$, $RuO_2$, and $IrO_2$. Lifetime of these anodes can be one of the important factors affecting the lifetime of concrete structure in cathodic protection. In this work, several anodes were made by sol-gel method and thermal decomposition method and the lifetime of these anodes was evaluated by NACE international standard test method, TM 0294-94. Also, we did analyze the properties of coated metal oxides.

Development of Hybrid Sol-Gel Coating to Prevent Corrosion of Magnesium Alloys (마그네슘 합금의 방청을 위한 하이브리드 졸-겔 코팅제의 개발)

  • Lee, Dong Uk;Kim, Young Hoon;Moon, Myung Jun
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • The high rate of corrosion of magnesium alloys makes it limited for industrial applications. Therefore, surface treatment is required to enhance their corrosion resistance. In our study, a chemical conversion coating for protecting the corrosion of the magnesium alloy, AZ31B, was prepared by using a phosphate-permanganate solution. The chemical conversion coating had a limited protection ability due to defects arising from cracks and pores in the coating layer. The sol-gel coating was prepared by using trimethoxymethylsilane (MTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS) as precursors, and aluminum acetyl acetonate as a ring opening agent. The corrosion protection properties of sol-gel and conversion coatings in 0.35wt% NaCl solution were measured by the electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization test. The EIS results indicated that the resistance of the chemical conversion coating with the sol-gel coating was significantly improved through the sol-gel sealed phosphate-permanganate conversion coating. The results of the potentiodynamic polarization test revealed that the sol-gel coating decreased the corrosion current density ($I_{corr}$). The SEM image showed that the sol-gel coating sealed conversion coating and improved corrosion protection.

A Study on the Characteristics of Galvalume Sheet (55%A1-43.4%Zn-1.6%Si) (55% A1 - 43.4% Zn - 1.6% Si 합금도금 강판의 특성에 관한 연구)

  • 김순경
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.310-315
    • /
    • 1997
  • An extensive corrosion study was initiated by galvalume steel sheet manufacturing company to clarify the corrosion behavior of zinc and zinc and zinc-alloy coated automotive sheet steel in out panel and electrical application. Since the early 1980's the use of zinc and aluminum alloy coated steel for vehicular corrosion protection has increased drastically. This paper describes the evaluation of formability, weldability and painted corrosion performance of galvalume steel sheet. This paper presents an overview of the program and some initial test results on the weldability, lifetime of the electrode tip shape of the spot welding and corrosion protection. Galvalume steel sheet improved corrosion performance and spot weldability of galvalume steel has no problem for the variation of welding current. And tip lifetime was changed according to the influence of shape.

  • PDF

A Study on the Characteristics of Gavalume Steel Sheet (갈바륨 강판의 특성에 관한 연구)

  • 김순경
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.2
    • /
    • pp.74-80
    • /
    • 1998
  • An extensive corrosion study was initiated by galvalume steel sheet manufacturing company to clarify the corrosion behavior of zinc and zinc-alloy coated automotive sheet steel in out panel and electrical application. Since the early 1980's the use of zinc and aluminum alloy coated steel for vehicular corrosion protection has increased drastically. This paper describes the evaluation of formability, weldability and painted corrosion performance of galvalume steel sheet. This paper presents an overview of the program and some initial test results on the weldability, lifetime of the electrode tip shape of the spot welding and corrosion protection. Galvalume steel sheet improved corrosion performance and spot weldability of galvalume steel sheet has no problem for the variation of welding current. And tip lifetime was changed according to the influence of shape.

  • PDF

Effect for Steel Corrosion Protection in Concrete applying Surface Coating Anode and Solar Battery (표면(表面) 코팅 양극(陽極)과 태양전기(太陽電氣)를 이용한 콘크리트 중의 철근(鐵筋) 부식(腐食) 방지(防止)를 위한 효과)

  • Kim, Jong-Pil;Park, Kwang-Pil;Kim, Seong-Soo;Jung, Ho-Seop;Lee, Seung-Tae
    • Resources Recycling
    • /
    • v.18 no.4
    • /
    • pp.44-51
    • /
    • 2009
  • In order to verify the effect of Surface Coating Anode and Solar Battery anode system, accelerated tests in the presence or absence of some chloride content and cracks were carried out. The potential-decay, protection potential and corrosion current density of reinforcing steel in concrete specimen were measured to evaluate the effectiveness of the system. From the test results, the application of the system led to the satisfaction on NACE's criterion in all mixtures of concrete. Additionally it was found that protection potential and corrosion current density were satisfied due to the application of Surface Coating Anode and Solar Battery anode system.

ICCP Control and Monitoring System for Ships

  • Oh, Jin-Seok;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.30 no.4
    • /
    • pp.291-294
    • /
    • 2006
  • Corrosion is never avoided in the use rf materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic Protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. This thesis is about the ICCP control and monitoring system, which brings protection against the corrosion of the ship's hull in the sea environments. The test system for ICCP is composed of a power supply, anode, reference electrode and controller. The test system is composed power supply, anode, ref electrode, shunt and etc. The protection current is sent to the protection area though anode. Reference electrode senses whether or not the detected potential is within a range of protection of test equipment and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode by controller. The monitoring system with LabView is also detected in order to check the normal state of the system at operation period, because an operator does not always watch over this system and thus the system cannot operate well because rf his or her negligent management. This paper was studied the variation of potential and current density with environment factors, velocity and time, and the experimental results will be explained Also, It is suggested that this system can accommodate a ship's automation for SCMS(Ship Control and Management System) and will be very useful.

Validation of Some Protection Guidelines for Neighboring Pipelines against Fault Currents from Power Transmission Tower

  • Lee, Seong-Min;Song, Hong-Seok;Kim, Young Geun
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Fault current can be discharged from power transmission tower due to lightning or inadvertent contact of crane, etc. Pipelines in proximity to either the source of the ground fault or the substation grounding grid may provide convenient conductive path for the fault current to travel. Inappropriate measures to the neighboring pipelines against the fault current may cause severe damages to the pipes such as coating breakdown, arc burn, puncture, loss in wall thickness, or brittle heat-affected zone. Like inductive and conductive AC coupling, steadily induced fault current right after the coating breakdown can lead to corrosion of the pipeline. In this work, some protection guidelines against fault currents used in the field have been validated through the simulation and analytical method.