An Experimental Study on the Application of Cathodic Protection By Applying Zn-Al Metal Spray to an RC Structure  

Han, Man-Hae (Weathering Center, Korea Conformity Laboratories)
Yoo, Jo-Hyeong (School of Architecture & Architectural Engineering, Hanyang University(ERICA Campus))
Lim, Young-Chul (Department of Architectural Engineering, Catholic University of Daegu)
Lee, Han-Seung (School of Architecture & Architectural Engineering, Hanyang University(ERICA Campus))
Publication Information
Journal of the Korea Institute of Building Construction / v.10, no.5, 2010 , pp. 21-29 More about this Journal
Abstract
Cathodic Protection has been introduced as a method of protecting metals under the ground or sea from corrosion. Since 1970, it has been applied to reinforced concrete structures as a corrosion protection method. After 1990, it became used around the world, and its usability has been well confirmed. But this method has some problems in terms of construction and economy. To solve these problems, a Cathodic Protection Method using a highly-durable metal spray was developed. First, the specimen was covered with anodic materials (Zn, Al) by using metal spray. The corrosion protection performance was confirmed by measuring the corrosion current of the specimen. Through the experiment, it is possible to confirm that the Cathodic Protection Method using a high metal spray provides effective protection against corrosion to reinforced concrete structures.
Keywords
Metal spray; Cathodic protection; Corrosion current density;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim KJ, Lee MH, Moon KM, Principle and application of cathodic protection for concrete structure. Magazine of the Korea Concrete Institute 2009;18(5):22-33
2 Paul C, Cathodic protection of steel in concrete, London U. K., E & Fn Spon; 1998
3 Kang CS, Prediction on the anti-corrosion life of steel applying Zn-Al thermal metal spray method by the electrochemical experiment [MS dissertation]. Hanyang University; 2006
4 Cheong HM, An TS, Kim HS, Han BK, Current state and prospect of electrochemical techniques for protection of steel corrosion in concrete. Magazine of the Korea Concrete Institute 2009;18(5):16-21
5 Kim SS, Kim HS, Kim JP, Effect of the protection for rebars by embeded sacrificial anode in concrete. Journal of the Korea Concrete Institute 2001;13(2):1207-1212
6 Lee HS, Development for finishing method of concrete structures applying metal spraying system. Journal of the Korea Concrete Institute 2001;13(2):1225-1228
7 Huet B, L’hostis V, Santarini G, Feron D, Idrissi H, Steel corrosion in concrete: Determinist modeling of cathodic reaction as a function of water saturation degree. Corrosion science 2007;49(4):1918-1932   DOI   ScienceOn
8 Bennet J, Turk T, Criteria for the cathodic protection of reinforced concrete bridge elements. SHRP-S-359, SHRP, US 1994;3-14
9 Jung SH, Lee MS, Experimental study on the corrosion protection properties and anticorrosive life of the Zn/Al metal spray method according to the contents ratio of Zn and Al. Journal of the architectural institute of Korea 2003;19(10):59-66
10 Rebar Corrosion Inspection. Ilkwang:1996
11 Jones DA, Principle and prevention of corrosion. DongHwa Technology Publishing Co.:1999
12 Cathodic protection of reinforced concrete bridge elements. A state-of-the-art report:1993