• Title/Summary/Keyword: Corrosion Potential 부식전위

Search Result 182, Processing Time 0.026 seconds

Electrochemical Studies of Lithium Ion Battery Current Collector in the Aprotic Electrolytes: I. Al Current Collector (비수용성 전해질내 리튬이온전지용 집전체의 전기화학적 특성 연구: I. Al 집전체)

  • Park, Heai-Ku
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.620-627
    • /
    • 1999
  • Electrochemical properties of the Al current collector being used in lithium ion batteries have been studied in the 4 different aprotic electrolytes(1 M $LiBF_4$ EC : DMC, 1 M $LiBF_4$ EC : EMC. 1 M $LiPF_6$ EC : DMC. 1 M $LiPF_6$ EC : EMC) employing cyclic voltammetry and impedance measurement. Al electrode showed a wide range of the electrochemical window(0.5~4.1 V vs. $Li/Li^{+}$). However, solid interfacial materials has been formed on the Al surface due to reduction of impurities($H_2O$, $O_2$, etc), lithium salts, and electrolytes at low applied potentials, and aluminum oxides in the highly oxidizing potential as well. Especially, Al current collector was susceptible to localized in consequence of impurities in electrolytes.

  • PDF

Study on Crack Monitoring System in Steel Structure (강부재의 균열 모니터링에 관한 연구)

  • Lee, Jae-Sun;Chang, Kyong-Ho;Hwang, Jee-Hoon;Park, Hyun-Chan;Jeon, Jun-Tai;Kim, You-Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 2011
  • Steel structure construction is currently increasing on account of the many merits of steel structures. Due to numerous environmental factors, many cracks and extensive corrosion occur in steel structures, which cause the deterioration of the performance and life cycle of such structures. Maintenance of steel structures is thus strongly demanded, for safety control. The inspection methods that are currently being used, however, are very limited and can detect only local defects in steel structures. They also take much time to use and incur high maintenance costs. Moreover, such methods cannot be applied to huge steel structures, which men find unapproachable. They also require much time due to the need for periodic checks, and may lead to cost loss. Therefore, the development of a monitoring system that can detect defects in whole structures and can reduce the repair and strengthening costs at an early stage is very much needed. In this study, the generation and propagation of cracks were monitored via the electric-potential-drop method (EPDM).

Study on Characteristics of SCC and AE Signals for Weld HAZ of HT-60 Steel (HT-60강 용접부의 SCC및 AE신호특성에 관한 연구)

  • Na, Eui-Gyun;Yu, Hyo-Sun;Kim, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.62-68
    • /
    • 2001
  • In order to characterize the microscopic fracture behaviour of the weldment din stress corrosion cracking(SCC) phenomena, SCC and acoustic emission(AE) tests were carried out simultaneously and the correlation between mechanical paramenters obtained from SCC and AE tests was investigated. In the case of base metal, much more AE events were produced at -0.5V than at -0.8V because of the dissolution mechanism before the maximum load. Regardless of the applied voltages to the specimens, however, AE events decreased after the maximum load. In the case of weldment, lots of AE events with larger amplitude $range(40{\sim}100dB)$ were produced because of the singularities of weld HAZ in comparision to the base metal and post-weld heat-treated(PWHT) specimens. Numerous and larger cracks for the weldment were observed on the fractured surfaces by SEM examination. From these results, it was concluded that SCC for the weldment appeared most severely in synthetic seawater. Weld HAZ was softened by PWHT which also contributed to the reduced susceptibility to corrosive environment in comparison to the weldment.

  • PDF

A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle (차량을 이용한 원격전위 측정방법 개발에 관한 연구)

  • Ryou, Young-Don;Jo, Young-Do;Kim, Jin-Jun;Seo, Min-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.64-71
    • /
    • 2016
  • According to the urban gas business law, electrical corrosion prevention measures shall be installed to the buried gas pipelines and the pipe-to-soil potentials should be measured at the test box at least once a year. Most of the test boxes installed in urban area are usually located on the road where the vehicle travels, therefore, it is difficult to measure the CP potentials at the test boxes. That is, we need traffic control when carrying out the measurement of the CP potentials on daytime when the traffic is heavy, or we have to measure the potentials in the late night when the traffic is light. To solve these difficulties, we have studied remotely CP potential measuring method by using the patrol car. We have installed solid reference electrodes and data loggers under the test boxes on the site and received the CP potentials from the data loggers when the vehicle moves. It was difficult to send and receive the data because the data logger was located under the ground. We have applied 3 different method including 2 antenna systems to achieve best effective way in receiving the data. We have found the remote CP measuring method by using a car can save more 20 times of measuring time than conventional measuring methods.

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (1) -Development of Electro-Deposition System Using Sea Water (해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (1) -해수전착 코팅 시스템 개발)

  • Kwon, Seung Jun;Lee, Myeong Hoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.78-87
    • /
    • 2012
  • This study is for developing a system for electro-deposition utilizing sea water containing various ions like calcium and magnesium. This is the first step research for the final goal which is a development of anti-corrosive steel for RC structure, so that this paper is mainly focused on the development for electro-deposition system. Optimum conditions for steel coating is obtained through various tests considering anode type, temperature, duration time, and current density. The composition of electro-deposition is analyzed through SEM, EDS, and XRD and it is evaluated to be $CaCO_3$ and $Mg(OH)_2$. Through measuring polarization potential and current density in the coated steel, the coating layer from the developed system is evaluated to have high resistance to steel corrosion. Additional tests and discussions on durability and structural performance in the coated steel from this work will be performed for the second step research.

Atmospheric Effects on Growth Kinetics and Electronic Properties of Passive Film of Aluminum in Borate Buffer Solution (Borate 완충용액에서 알루미늄의 산화피막의 생성과정과 전기적 성질에 대한 대기의 영향)

  • Kim, Younkyoo
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.3
    • /
    • pp.169-176
    • /
    • 2016
  • In a borate buffer solution, the growth kinetics and the electronic properties of passive film on aluminum were investigated, using the potentiodynamic method, chronoamperometry, and multi-frequency electrochemical impedance spectroscopy. The corrosion of aluminum was heavily influenced by the degree of oxygen concentration because of the increasing reduction current. The oxide film formed during the passivation process of aluminum has showed the electronic properties of n-type semiconductor, which follow from the Mott-Schottky equation. It was found out that the passive film (Al(OH)3) of Al formed in the low electrode potential changes to Al2O3 while the electrode potential increases. The growth kinetics data as measured by chronoamperometry suggests a mechanism in which the growth of the film of Al2O3 is determined by field-assisted transport of ions through the film.

Effect of Cathodic Protection of Adjacent Steel Piles on the Life of Sacrificial Anode (희생양극의 수명에 미치는 인접 강파일의 음극방식 영향)

  • Moon, Kyung-Man;Lee, Kyu-Hwan;Cho, Hwang-Rae;Lee, Myung-Hoon;Kim, Yun-Hae;Kim, Jin-Gyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.76-81
    • /
    • 2008
  • There are two cases when the life of a sacrificial anode is shortened from the designed life: one case results from self-corrosion of the anode due to contamination by sea water in the other case, however, electrical current to protect some given steel piles overflows to protect other, adjacent non-protected steel piles. In this study, the variation of polarization potential of nine steel piles, being protected cathodically and with anode-producing current between anode and steel piles, was investigated. Parameters were varied, such as the eighth and ninth steel piles either connected electrically or not, and whether the ninth steel pile was protected by another sacrificial anode or not. The current produced by the sacrificial anode decreased when the ninth steel pile was cathodically protected by the anode of another pile. However, produced current increased when the ninth steel pile was not connected to another anode. The study concludes that the life of a sacrificial anode can be prolonged or shortened depending on whether adjacent steel piles are cathodically protected or not.

Durability Evaluation of Inorganic-Impregnated Concrete Exposed to Long-Term Chloride Exposure Test (무기계 침투제를 적용한 콘크리트의 장기폭로실험을 통한 염해 내구성 평가)

  • Kwon, Seung-Jun;Park, Sang-Soon;Lho, Byeong-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 2008
  • The repair technique using surface impregnation of reactive compound is so effective for deteriorated concrete structures that many researches are recently focused on these works. Particularly, inorganic impregnant is regarded as ecofriendly material because there is no air-pollution during manufacturing process as well as field coating works. Furthermore, The delamination between old concrete and impregnated surface does not occur, resulting from different material characteristics. In order to evaluate the durability performance of surface-impregnated concrete, durability evaluation through the long-term exposure tests is significant, however, experiments are usually limited to the temporary and qualitative laboratorial scope. In this study, durability characteristics for inorganic and organic/inorganic impregnated concrete specimens are evaluated through longterm chloride exposure test. The specimens with 21MPa and 34MPa strength have been prepared and exposed to chloride attack in the atmospheric, tidal, and submerged conditions. Evaluation for compressive strength, chloride penetration, and electrical potential (half cell potential) for steel corrosion are performed for the specimens exposed for 2 years. From the results, no distinct strength gaining is observed but the resistance to chloride penetration and steel corrosion is evaluated to be improved through surface impregnation. The more improved resistance to chloride attack is measured in the inorganic impregnated concrete and the results from atmospheric condition show more improved resistance to chloride attack than those from submerged and tidal condition.

Properties analysis of environment friendly calcareous deposit films electrodeposited at various temperature conditions in natural seawater (천연해수 중 온도 변화에 따라 전착한 환경친화적인 석회질 피막의 특성 분석)

  • Lee, Chan-Sik;Kang, Jun;Lee, Myeong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.779-785
    • /
    • 2015
  • Cathodic protection is recognized as the most cost-effective and technically appropriate corrosion prevention method for the submerged zone of offshore structures, ships, and deep-sea facilities. When cathodic protection is applied, the cathodic currents cause dissolved oxygen reduction, generating hydroxyl ions near the polarized surface that increase the interfacial pH and result in enhanced carbonate ion concentration and precipitation of an inorganic layer whose principal component is calcium carbonate. Depending on the potential, magnesium hydroxide can also precipitate. This mixed deposit is generally called "calcareous deposit." This layer functions as a barrier against the corrosive environment, leading to a decrease in current demand. Hence, the importance of calcareous deposits for the effective, efficient operation of marine cathodic protection systems is recognized by engineers and scientists concerned with cathodic protection in submerged marine environments. Calcareous deposit formation on a marine structure depends on the potential, current, pH, temperature, pressure, sea-water chemistry, flow, and time; deposit quality is significantly influenced by these factors. This study determines how calcareous deposits form in sea water, and assesses the interrelationship of formation conditions (such as the sea water temperature and surface condition of steel), deposited structure, and properties and the effectiveness of the cathodic protection.

The Behavior of Pitting Corrosion Associated with Microstructure of a Cast Lean Duplex Stainless Steel in Chloride Environments (염화물 환경에서 린 듀플렉스 스테인리스 주강의 미세조직과 연계한 공식 거동)

  • In-Sung Lee;Soon-Tae Kim;Chae-Jin Nam;Seung-Man Yang;In-Sung Cho;Seung-Mok Yoo
    • Journal of Korea Foundry Society
    • /
    • v.43 no.5
    • /
    • pp.230-240
    • /
    • 2023
  • The pitting corrosion behavior of 329LD cast lean duplex stainless steel and CF3M cast austenitic stainless steel was investigated in chloride environments. The pitting corrosion resistance of the 329LD alloy was superior to that of the CF3M alloy because the pitting potential, passive region, and critical pitting temperature of the low Ni-low Mo 329LD alloy were higher than those of the high Ni-medium Mo commercial CF3M alloy. There are two main reasons for the enhancement of the pitting corrosion resistance of high Cr-low Momedium N 329LD alloy compared to the low Cr-medium Mo CF3M alloy: First, the pitting resistance equivalent number (PRENδ+γ) value of the 329LD alloy is higher than that of the CF3M alloy. Second, the passive region of the 329LD alloy is larger than that of the CF3M alloy. It indicates that the synergistic effect of the three elements by adding high Cr and low Mo-medium N to the 329LD alloy enhances the passivity of the passive film, thereby increasing the pitting corrosion resistance. It was verified that based on the PRENγ of austenite (γ) and PRENδ of ferrite (δ) values calculated using an N-factor of 16, the pitting corrosion of the 329LD alloy was selectively initiated at the γ-phases because PRENγ value of austenite (γ) was smaller than that of ferrite (δ), and finally propagated from the γ-phase to the δ-phase.