• Title/Summary/Keyword: Corrosion Fatigue

Search Result 418, Processing Time 0.03 seconds

Experimental Study on Bond Stress-Slip Behavior of Reinforced Concrete Member Under Repeated Loading Considering Steel Corrosion (반복하중 하에서 철근부식을 고려한 철근콘크리트 부재의 부착응력-슬립 거동에 관한 실험적 연구)

  • Kim, Chul-Min;Kim, Jee-Sang;Park, Jong-Bum;Chang, Sung-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.545-548
    • /
    • 2006
  • This study includes the experimental investigation on the fatigue-bond behavior with respect to the various rates of steel corrosion. Major criteria of test variables are the rates of steel corrosion by chloride ion and the ratio of the applied stress to the bond failure stress. According to the test results, the slip versus number of load cycles relation was found to be approximately linear in double logarithmic scale, not only without steel corrosion but also with steel corrosion. This research will be helpful for the realistic durability design and condition assessment of reinforced concrete structures.

  • PDF

A Study on Wear Characteristics of Machine Structural Steel by Surface Modification (표면개질에 의한 기계구조용강의 마멸특성에 관한 연구)

  • Park Heung-Sik;Woo Kyu-Sung
    • Tribology and Lubricants
    • /
    • v.22 no.2
    • /
    • pp.73-78
    • /
    • 2006
  • The surface modification of automobile parts is of great technological importance for the improvement of corrosion resistance, wear resistance, fatigue strength and so on. Recently, research on the development of the technology of surface modification substituting 6-balance chrome process has progressively been achieved in automobile parts. Although the innovation technology for the improvement of the corrosion-resisting and wear resistant properties through post oxidation after nitrocarburising process had attracted a great attention. For this, anodically potentiodynamic polarisation testing was carried out to corrosion resistance and friction and wear experiment according to applied load and sliding distance was carried out to evaluate the wear resistance of machine structural steel with nitrocarburising and non-nitrocarburising SM45C. The presumed wear volume was calculated with the image processing far evaluation of wear resistance of two materials. The results show that the nitrocarburising had a distinguished corrosion resistance and wear resistance than non-nitrocarburising.

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF

Study on Localized Corrosion Cracking of Alloy 600 using EN-DCPD Technique (EN-DCPD 방법을 이용한 Alloy 600 재료의 국부부식균열 연구)

  • Lee, Yeon-Ju;Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.93-101
    • /
    • 2013
  • The object of this work is to establish an electrochemical noise(EN) measurement technique combined with a direct current potential drop(DCPD) method for monitoring of localized corrosion cracking of nickel-based alloy, and to analyze its mechanism. The electrochemical current and potential noises were measured under various conditions of applied stress to a compact tension specimen in a simulated primary water chemistry of a pressurized water reactor. The amplitude and frequency of the EN signals were evaluated in both time and frequency domains based on a shot noise theory, and then quantitatively analyzed using statistical Weibull distribution function. From the spectral analysis, the effect of the current application in DCPD was found to be effectively excluded from the EN signals generated from the localized corrosion cracking. With the aid of a microstructural analysis, the relationship between EN signals and the localized corrosion cracking mechanism was investigated by comparing the shape parameter of Weibull distribution of a mean time-to-failure.

A Study on Corrosive Behavior of Spring Steel by Shot-Peening Process (쇼트피닝 가공을 통한 스프링강의 부식거동에 관한 연구)

  • An, Jae-Pil;Park, Keyung-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.325-330
    • /
    • 2004
  • Recently, the request for the high strength of material is more and more increased in the area of industrial environment and machinery. To accomplish the high strength of materials, carbonizing treatment, nitrifying treatment, shot-peening method are representatively applied, however, shot-peening method is generally used among the surface processes. Shot peening is a cold working process used to impact Compressive residual stressed in the exposed surface layers. Benefits due to shot peening are increase in resistance to fatigue, stress corrosion cracking, fretting, galling, erosion and closing of pores. In this study, the influence of shot peening on the corrosion was investigated on spring steel immersed in 3.5% NaCl. The immersion test as performed on the two kinds of specimens. Corrsion potential, polarization curve, residual stress and etc, were investigated from experiment results. From test result the effect of shot peening on the corrosion was evaluated. The important results of the experimental study on the effects of shot peened on the environment corrosion of spring steels are as follows; In case of corrosion potential, shot peened specimen shows more activated negative direction as compared with parent mental. Surface of specimen, which is treated with the shot peened is placed as more activated state against inner base metal. It can cause t도 anti-corrosion effect on the base metal.

  • PDF

A study on corrosion resistance of Ti-Nb alloys by Nb contents (Nb 함량에 따른 Ti-Nb계 합금의 내식성에 대한 연구)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • Titanium alloys have been used for dental materials due to it's very good biocompatibility. Ti-6Al-4V alloy instead of pure titanium is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and carcinogenicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. The Ti-Nb alloys has designed and examined corrosion resistance. Ti-3wt.%Nb($\alpha$type), Ti-20wt.%Nb(${\alpha}+{\beta}$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The corrosion resistance of Ti alloys was evaluated by potentiodynamic polarization test in the solution of 0.9% NaCl and 5% HCl. The results can be summarized as follows: 1) For the corrosion test in the solution of 0.9% NaCl and 5% HCl, the corrosion behaviour of Ti-Nb alloys was similar to ASTM grade 2 CP Ti. 2) The corrosion resistance of Ti-20Nb alloy was better than that of CP-Ti, Ti-3Nb, Ti-40Nb alloy in 0.9% NaCl and 5% HCl, solutions.

  • PDF

Failure Analysis of SCM435 Bolt for Fixing Automotive Air Brake Spring (자동차 에어 브레이크 스프링 고정용 SCM435 볼트의 파손 해석)

  • Yun, Seo-Hyun;Kim, Min-Heon;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • This study analyzed the causes of failure of SCM435 bolts that fix the springs of automobile air brakes that have been fractured during use. The cause of failure was analyzed using SEM, EDS, metallogical microscope and Vickers hardness tester. In the fracture, the ratchet mark began at the outer boundary of crack origin, and the grains at crack origin were found to have clear intergranular corrosion. One SCM435 bolt was subjected to a stress of 398 MPa, it's a stress of about 80% of the fatigue limit. As a result of such a large applied stress, cracks occurred at the corrosion origin and were fractured. In order to prevent the SCM435 bolt from fracture, it is necessary to use the correct composition, the accuracy of heat treatment, preventing damage by external impact, preventing corrosion of the damage part by moisture, and introduction a compressive residual stress by peening.

Reliability of Maintained Hull Girders of Two Bulk Carrier Designs Subjected to Fatigue and Corrosion

  • Soares, C.Guedes;Garbatov, Y.
    • Journal of Ship and Ocean Technology
    • /
    • v.3 no.1
    • /
    • pp.27-41
    • /
    • 1999
  • The objective of the paper is to study the impact of changing the traditional hull design of bulk carriers by providing them with a double hull while keeping the same deadweight. It is demonstrated that by introducing the double hull the structural reliability is increased throughout the entire life and also the extend of the needed repair is reduced. The results are obtained with recently developed mathematical tools for the reliability assessment of ship hulls subjected to the existence of multiple cracks both in the stiffeners and in the plating and it models the crack growth process. The effect of corrosion is represented as time dependent. The long-term stress range acting on the elements is defined as a function of the local transverse pressure of the internal cargo and outside sea water combined with the stresses resulting from the longitudinal bending of the hull, which is a combined with the stresses resulting from the longitudinal bending of the hull, which is a combineation of horizontal and vertical bending moments. The effect of maintenance actions is modelled as a stochastic process. The results show that a different design of the midship section improves the structural safety and also the economy with respect to structural repair of bulk carriers.

  • PDF

Development of the Condition Assessment Scheme of Aged Ships (노후선박의 Condition Assessment Scheme의 개발)

  • 박영일;백점기;이제명;고재용
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.77-82
    • /
    • 2004
  • This study presents reliability assessment of merchant ships with focus on hull girder ultimate limit state, taking into account the time-dependent effects of corrosion, fatigue cracking and local denting. Some considerations for establishing a reliability-based repair and maintenance scheme are also made so as to keep a ship's hull girder strength reliability at an acceptable level even later in life.

  • PDF

A Study of Two-Mode Failure Model for Crystalline Si Photovoltaic Module (실리콘 태양전지 모듈의 two-mode failure 모델의 연구)

  • Choi, Ki Young;Oh, Won Wook;Kang, Byung Jun;Kim, Young Do;Tark, Sung Ju;Kim, Donghwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.62.2-62.2
    • /
    • 2011
  • To guarantee 20-25 years to the lifetime of the PV modules without failure, reliability test of the module is very important. Field-aged test of the outdoor environment is required. However, due to time constraints, accelerated testing is required to predict the lifetime of PV modules and find causes of failure. Failure is caused by many complex phenomena. In this study, we experimented two accelerated tests about corrosion and fatigue, respectively. First, temperature cycling test for fatigue were tested and Coffin-Manson equation was analyzed. Second, damp heat test for corrosion were tested and Eyring equation were analyzed. Finally, using two-mode failure model, we suggest a new lifetime model that analyze the phenomenon by combining two kinds of data.

  • PDF