A Probabilistic Corrosion Rate Estimation Model for Longitudinal Strength Members of Bulk Carriers

  • Paik, Jeom-Kee;Kim, Sung-Kyu;Lee, Sang-Kon;Park, Young-Eel
    • Journal of Ship and Ocean Technology
    • /
    • 제2권1호
    • /
    • pp.58-70
    • /
    • 1998
  • Many bulk carrier losses have been reported of late, and one of the possible causes of such casualties is thought to be the structural failure of aging hulls in rough weather. Clearly, in such cases, vessels that start out belong adequate somehow become marginal later in life. Fatigue and corrosion related potential problems may be the most important factors affecting such age related vessel damage. With respect to fatigue, extensive studies have been done worldwide both experimentally and theoretically, and the results have been applied to some extent. However, in the case of corrosion effects, additional research is still needed to better understand, clarify and address the various strength uncertainties and their effects on structural behavior. This paper develops a probabilistic corrosion rate estimation model for the longitudinal strength members of bulk carriers. The model is based on available statistical data for corrosion of existing bulk carriers. The corrosion data collected are documented for future use.

  • PDF

Effect of Seawater Concentration on Electrochemical Corrosion of Duplex Stainless Steel

  • Ho-Seong Heo;Hyun-Kyu Hwang;Dong-Ho Shin;Seong-Jong Kim
    • Corrosion Science and Technology
    • /
    • 제23권4호
    • /
    • pp.255-265
    • /
    • 2024
  • Duplex stainless steels (UNS S32205, UNS S32750) are used in various environments. The potentiodynamic polarization tests were conducted at 30 ℃ in order to study the electrochemical corrosion behaviors of duplex stainless steels under different seawater concentrations (fresh water, seawater, mixed water). The results of Tafel analysis in seawater showed that UNS S32205 and UNS S32750 had the highest corrosion current densities at 6.12 × 10-4 mA/cm2 and 5.41 × 10-4 mA/cm2, respectively. The pitting potentials of UNS S32205 and UNS S32750 were comparable to or higher than the oxygen evolution potential in fresh water, mixed water, and seawater. The maximum damage depths and surface damage ratio caused by pitting corrosion increased with chloride concentration. The synergy effect of molybdenum and nitrogen enhances the concentration of Mo, Ni, and Cr at the interface of the metal-electrolyte. In particular, in the case of nitrogen, NH3 and NH4+ are formed to compensate for the pH drop in the pitting region, thereby strengthening the repassivation of the film. The excellent corrosion resistance of UNS S32750 is attributed to the strengthening effect of the chromium oxide film due to the presence of molybdenum and nitrogen.

인위적 표면 단면손상 수준에 따른 원형 부재의 인장성능 변화 (Tensile Strength Change of Circular Structural member with Artificial Sectional Surface Damage)

  • 하민균;권태윤;이원홍;안진희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권3호
    • /
    • pp.100-109
    • /
    • 2021
  • 본 연구에서는 부식에 의하여 발생하는 표면 단면손상을 고려하여 인위적인 표면 단면손상이 도입된 원형인장 부재의 인장성능 변화를 평가하였다. 인장성능 평가를 위하여 부식수준에 따른 인위적인 단면손상을 손상 폭과 높이를 변화시켜 원형강관 시험체 표면에 도입하였으며, 단면손상 수준에 따른 인장성능 변화를 평가하였다. 인장강도 실험 결과, 원형단면 강관부재의 인장강도는 강관부재의 길이 방향 손상이 아닌 부재 둘레 방향 손상의 영향을 받는 것으로 나타났으며, 부재의 파괴는 손상이 발생한 부재의 최소 단면에서 발생하는 것으로 나타났다. 표면에 불규칙한 손상이 도입된 강관 시험체의 단면조건을 명확하게 평가할 수 없으므로, 단면손상으로 인한 인장강도 변화를 정량적으로 비교하기 위하여 동일 단면 감소효과가 고려된 강관 부재에 대한 비선형 구조해석을 실시하였다. 비선형 구조해석 결과, 실제 부재 표면에 국부적 단면손상이 발생한 부재의 인장강도는 동일 단면 감소효과를 고려한 부재의 인장강도에 비하여 상대적으로 급격하게 저하하는 것으로 평가되었다. 국부부식과 같이 표면에 불규칙한 단면손상이 발생한 부재의 잔존인장성능은 인장시험과 등가손상 단면과 구조해석 결과로부터 평가된 상관계수를 이용하여 평가 및 예측될 수 있을 것이다.

지하연료저장탱크의 부식손상 방지에 관한 연구(1) (바다모래에서 부식 손상) (Study on the Prevention of Corrosion Damage for Underground Fuel Stroage Tank(1) (Corrosion Damage under the Sea Sand))

  • 임우조;서동철
    • 수산해양기술연구
    • /
    • 제37권1호
    • /
    • pp.65-70
    • /
    • 2001
  • 바다모래에 의해 뒷채움된 지하연료저장탱크용 연강재의 부식전류밀도, 개로전위, 전식거동 및 연간부식률에 관하여 연구한 결과 다음과 같은 결론을 얻었다. 1) 습바다모래 중에서 비저항이 감소할수록 개로전위는 비전위화되고, 부식전류밀도는 높게 배류된다. 2) 습바다모래의 비저항이 감소할수록 인가전위 부가에 의한 부식전류밀도는 자연전위에서의 부식전류밀도보다 급격히 증가한다. 3) 습바다모래 중에서 비저항이 감소할수록 연간부식률은 선형적으로 증가함으로 지하연료저장탱크에 바다모래로 뒷채움하는 경우 습기가 유입하면 지하연료저장탱크의 부식성은 민감할 것으로 판단된다.

  • PDF

5083-O 알루미늄 합금의 진폭에 따른 캐비테이션 침식 특성 평가 (Evaluation of Cavitation Characteristics of 5083-O Al Alloy with Amplitude)

  • 이승준;김성종
    • Corrosion Science and Technology
    • /
    • 제11권5호
    • /
    • pp.205-212
    • /
    • 2012
  • With recent advances in engineering and technology, a damage on industrial machineries performing high-speed and high-power requirements has become a problem. There is an increasing possibility of cavitation damage, especially in pumps, propellers and high-speed vessels in a flowing liquid accordingly. There are several factors affecting cavitation damage on materials, including viscosity, pressure, temperature, amplitude applied. In this study, effects of cavity pressure in seawater on the damage for 5083-O aluminium alloy were evaluated by modulating amplitude. Trend of the damage with respect to time and amplitude was analyzed comparatively, and surface degradation of specimens was investigated by using Scanning Electron Microscope(SEM) and 3D microscope. The result reveals that the amount of the damage increased consistently with the increase in time and amplitude while the plastic deformation zone where no appreciable damage occurred was in less than 30 minutes.

순환동전위 분극실험을 이용한 스테인리스강의 그린데스용액에서 전기화학적 특성에 미치는 온도의 영향 (Effect of Temperature on Electrochemical Characteristics of Stainless Steel in Green Death Solution Using Cyclic Potentiodynamic Polarization Test)

  • 황현규;김성종
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.266-280
    • /
    • 2021
  • Since 2020, the International Maritime Organization (IMO) has updated regulations on the sulfur content to be less than 0.5% in exhaust gas emitted from ships. Accordingly, the exhaust gas post-treatment device for ships, which is SOx/NOx reduction technology, was introduced. However, the exhaust gas post-treatment device is suffering corrosion because of the harsh corrosive environment formed by sulfate and chlorine oxide through the desulfurization process. In this investigation, cyclic potentiodynamic polarization (CPDP) experiment for UNS S31603 and UNS N08367 was performed in a green death solution that simulates the environment of a desulfurization device. The corrosion rate of UNS S31603 at the highest temperature was about 3 times higher than that of UNS N83067. Also, electron microscope scan revealed corrosion type UNS N83067 presents intergranular corrosion tendency. On the other hand, UNS S31603 was observed as general corrosion. The α values of UNS N08367 at 30 ℃ and 60 ℃ were higher than those of UNS S31603, thus UNS N08367 is considered to have a higher local damage tendency. Whereas, since the α value of UNS S31603 at 90 ℃ is larger than that of UNS N08367, UNS S31603 is considered to have a higher local damage trend.

Behavior of steel-concrete jacketed corrosion-damaged RC columns subjected to eccentric load

  • Hu, Jiyue;Liang, Hongjun;Lu, Yiyan
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.689-701
    • /
    • 2018
  • Corrosion of steel reinforcement is a principal cause of deterioration of RC columns. Making these corrosion-damaged columns conform to new safety regulations and functions is a tremendous technological challenge. This study presented an experimental investigation on steel-concrete jacketed corrosion-damaged RC columns. The influences of steel jacket thickness and concrete strength on the enhancement performance of the strengthened specimens were investigated. The results showed that the use of steel-concrete jacketing is efficient since the stub strengthened columns behaved in a more ductile manner. Moreover, the ultimate strength of the corrosion-damaged RC columns is increased by an average of 5.3 times, and the ductility is also significantly improved by the strengthening method. The bearing capacity of the strengthening columns increases with the steel tube thickness increasing, and the strengthening concrete strength has a positive impact on both bearing capacity, whereas a negative influence on the ductility. Subsequently, a numerical model was developed to predict the behavior of the retrofitted columns. The model takes into account corrosion-damage of steel rebar and confining enhancement supplied by the steel tube. Comparative results with the experimental results indicated that the developed numerical model is an effective simulation. Based on extensive verified numerical studies, a design equation was proposed and found to predict well the ultimate eccentric strength of the strengthened columns.

해수 환경에서 슈퍼 오스테나이트 스테인리스강의 전기화학적 거동에 미치는 캐비테이션 진폭의 영향 (Effect of Cavitation Amplitude on the Electrochemical Behavior of Super Austenitic Stainless Steels in Seawater Environment)

  • 허호성;김성종
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.138-146
    • /
    • 2022
  • The cavitation and potentiodynamic polarization experiments were conducted simultaneously to investigate the effect of cavitation amplitude on the super austenitic stainless steel (UNS N08367) electrochemical behavior in seawater. The results of the potentiodynamic polarization experiment under cavitation condition showed that the corrosion current density increased with cavitation amplitude increase. Above oxygen evolution potential, the current density in a static condition was the largest because the anodic dissolution reaction by intergranular corrosion was promoted. In the static condition, intergranular corrosion was mainly observed. However, damage caused by erosion was observed in the cavitation environment. The micro-jet generated by cavity collapse destroyed the corrosion product and promoted the repassivation. So, weight loss occurred the most in static conditions. After the experiment, wave patterns were formed on the surface due to the compressive residual stress caused by the impact pressure of the cavity. Surface hardness was improved by the water cavitation peening effect, and the hardness value was the highest at 30 ㎛ amplitude. UNS N08367 with excellent mechanical performance due to its high hardness showed that cavitation inhibited corrosion damage.

전라남도 등록문화재의 수리공사에 관한 조사 연구 -수리공사에 따른 재료 및 형태 변화를 중심으로- (A study on repairing construction of Registered Cultural Properties of Jollanamdo -In consideration of material and patterns by repairing project-)

  • 신웅주;길종원
    • 한국농촌건축학회논문집
    • /
    • 제12권4호
    • /
    • pp.1-11
    • /
    • 2010
  • This study is a research examining reshaped pattern in the perspective of repairing parts and materials through repairing renovation of registered cultural properties constructed in modern times and results are as followings. Repairing construction of registered cultural properties of Jollanamdo according to parts is shown numerously in the order of roof, walls and windows, and mostly outworn as time passes on and leakage were the main cause of repair. Also when original shape was damaged by previous repair in the past, and this was another reason of repairing. It was surveyed that among the repairing job repair of damage occurred on the part of roofing area including water leakage, corrosion and damage of roofing material, and damage of groove channel were the most main cause of repair. Especially when roof leakage is occurred by outworn of roofing materials, this cause corrosion and damage of materials due to the damage of leakage parts and this cause repeating cycles of worse leakage again and again. Main repairing materials which deform the original shape of registered cultural properties were confirmed as copper plate used on the roof. Copper plate showing high frequency of application which replaces groove slate or cement roofing tile used on the roof before has high durability and anti-corrosion but it is considered improper material to recover original shape.

Study on Atmospheric Corrosion for Two Different Marine Environments in India

  • Saha, Jayanta Kumar
    • Corrosion Science and Technology
    • /
    • 제6권3호
    • /
    • pp.120-127
    • /
    • 2007
  • In any developing nation major investment goes for infrastructure and it is not exception in India. Good numbers of buildings, bridges, shopping malls, car parks etc. are coming up with steel for sustainable development. Thus protecting the structures from corrosion are the challenges faced by professionals for all types of steel structures. About 3% of GDP is accounted for loss due to corrosion. To combat this up to date corrosion map is called for as the country has wide variation of climatic zones with vastcoastline. Logically organic paint system can be prescribed based on the corrosion rate on bare steel with respect to environment. Present paper will emphasis on the study conducted on two types of structural steel coated with organic paint located in twomarine environment having been exposed for three years, Test coupons made from steels both bare and coated are deployed at two field stations having marine (Digha) and industrial marine (Channai) environments. Various tests like AC impedance DC corrosion, polarisation, salt spray test, $SO_2$ chamber and Raman spectroscopy were carried out both in laboratory on fresh as well as coupons collected from exposure sites. Rust formed on the bare and scribed coated coupons are investigated. It is found that normal marine environment at Digha exhibits higher corrosion rate than polluted marine environment in Channai. Rust analysis indicates formation of ${\propto}$-FeoOH protects or reduces corrosion rate at Channai and formation of non-protective ${\gamma}$-FeoOH increases corrosion rate at Digha. The slower corrosion rate in Channai than at Digha is attributed due to availability of $SO_2$, in the environment, which converts non‐protective rust ${\gamma}$-FeoOH to protective rust ${\propto}$-FeoOH. While comparing the damage on the coated panels it is found that low alloy structural steel provides less damage than plain carbon steel. From the experimentations a suitable paint system specification is drawn for identical environments for low medium and high durability.