• Title/Summary/Keyword: Corrosion Cell

Search Result 388, Processing Time 0.023 seconds

Electrochemical Corrosion Characteristics of AISI-type 316 L Stainless Steel in Anode-Gas Environment of MCFC (용융탄산염 연료전지의 Anode가스 분위기에서 AISI-type 316L stainless steel의 전기화학적 부식 특성)

  • Lee, Kab-Soo;Lim, Tae-Hoon;Hong, Seong-Ahn;Kim, Hwa-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • The corrosion of the metallic cell components is blown to be one of the major reason f3r the performance degradation and subsequently the life-time limitation of the MCFC. To elucidate the corrosion phenomena, a corrosion study with the AISI-type 316L stainless steel, the most widely used separator material, in 621Li/38K carbonate eutectic melt was carried out. Corrosion phenomena in an MCFC were observed to differ from one location to another due to different environmental condition. The stability of passive film was found to be responsible fur the variations in corrosion phenomena. According to the potentiodynamic analysis, the passive film formed in anode-gas environment was less stable than in cathode-gas environment. The potentiostatic method combined with XRD analysis in addition to the cyclicvoltammetry was conducted to get an insight on variety corrosion reaction of AISI-type 316L stainless steel in a carbonate melt.

Ion Release and Biocompatibility of Sintered Ni-Cr-Ti Alloy for Dental Prosthodontics (치과보철용 Ni-Cr-Ti소결체합금의 이온용출과 생체적합성)

  • Choe, Han-Cheol;Kim, Seung-Hui
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.360-365
    • /
    • 2017
  • In this study, ion release and biocompatibility of sintered Ni-Cr-Ti alloy for dental prosthodontics have been researched by corrosion and cell culture test. The microstructures of the alloys were observed by optical microscope, and corrosion behavior was investigated using potentiostat (Model PARSTAT 2273, EG&G, USA). Cell culture was carried out using hGf cell in DMEM (Welgene Inc., South Korea) supplemented with 10% fetal bovine serum (FBS) (Welgene Inc., South Korea) and antibiotic antimycotic solution (Welgene Inc., South Korea). After corrosion and cell culture test, surface morphologies were observed by field-emission scanning electron microscopy. For wettability behaviors, contact angles were measured by wettability test. As the content of Ti increased, the number of pit decreased and the corrosion resistance was improved from anodic polarization test, also, polarization resistance of samples containing Ti remarkably improved as compared with the alloy not containing Ti. The sintered alloy showed a low contact angle due to the pores formed on the surface. The addition of Ti element showed that the cell survival rate was better than that of the control group.

Influence of Loading on the Corrosion of Reinforcing Bar (철근콘크리트 보의 철근부식에 미치는 하중의 영향에 관한 연구)

  • 김형래;윤상천;지남용
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.171-179
    • /
    • 1999
  • The present research investigated the interaction among loading level, corrosion rate and flexural deflection of reinforced concrete beams. 10cm$\times$15cm$\times$110cm reinforced concrete beams were prepared and subjected to different levels of flexural loading, including 0%, 45% and 75% of the ultimate load. The beams with either a pre-load or a sustained load were also exposed to a laboratory environment with ponding and wetting/drying cycling at room temperature. Half cell potential and galvanized current measurements were taken to monitor corrosion process of reinforcing steel. After corrosion initiation, external current was applied to some of the beams to accelerate corrosion propagation. The beam deflections were recorded during the entire tests. The results indicate that loading level has significant effect on corrosion rate. The beams under a sustained load had much higher corrosion rate than the pre-loaded and then unloaded beams. Significant corrosion may result in an increase in beam deflection and affect serviceability of the structure. The present research may provide an insight into structural condition evaluation and service life predictions of reinforced concrete.

Ti-6Al-4V Alloy Fabricated by Additive Manufacturing Method Using Micro-droplet Cell and Critical Pitting Temperature Techniques and Evaluation of its Resistance to Corrosion (마이크로 드로플릿 셀 기법과 임계공식온도 측정 기법을 이용한 적층가공 Ti-6Al-4V 합금의 내식성 평가)

  • Seo, Dong-Il;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.129-137
    • /
    • 2018
  • The resistance to corrosion of additive manufactured (3D printing) Ti-6Al-4V alloys was investigated using micro-electrochemical tests. In terms of corrosion resistance, the acicular martensitic ${\alpha}^{\prime}$ phase in such additive manufactured Ti-6Al-4V was the focus of attention, and its behavior was distinct from that of conventional subtractive manufactured Ti-6Al-4V. To order to identify ${\alpha}^{\prime}$ phase, XRD tests were performed and micro Vickers hardness was measured for different grains (bright and dark grains) in the additive manufactured Ti-6Al-4V alloy. Micro-electrochemical tests were performed to measure corrosion resistance of bright and dark grains in the additive manufactured Ti-6Al-4V alloy with specially designed electrochemical micro-droplet cell. Critical pitting temperature (CPT) measurement was performed to evaluate the resistance to pitting corrosion of additive manufactured Ti-6Al-4V alloys with different volumes of ${\alpha}^{\prime}$ phase and subtractive manufactured Ti-6Al-4V alloy. The dark grains of the laminated Ti-6Al-4V alloy distributed broader than the bright grains measured with low microhardness. The dark grains of the Ti-6Al-4V alloy, which was rich in martensite ${\alpha}^{\prime}$, had lower general corrosion and pitting resistance than bright grains. As the fraction of martensite ${\alpha}^{\prime}$ phase increased, the resistance to the pitting corrosion decreased.

Analysis on IBEM for consideration on reinforced concrete slab resistance

  • Kyung, Je-Woon;Tae, Sung-Ho;Lee, Han-Seung;Lee, Sung-Bok
    • Computers and Concrete
    • /
    • v.5 no.6
    • /
    • pp.545-558
    • /
    • 2008
  • The corrosion of RC structures demonstrates very complicated forms of deterioration intermingled together but all pointing to a decrease in the durability of RC structures due to the corrosion of reinforcing bars. Until now, nondestructive techniques, such as half-cell potential and polarization resistance, have been widely available in the world. The former provides information on the probability of corrosion while the latter is associated with information concerning corrosion rates. Inversion by the boundary element method (IBEM) was developed for considering concrete resistivity. The applicability of the procedure was examined through a numerical analysis and electrolytic tests for RC slabs. A distribution in such concrete resistivity is relatively inhomogeneous including cracks on the surface of slabs. Regarding cracks in concrete, the relative coefficient of concrete resistance was introduced to perform its analysis. Further, the procedure will be developed to identify the corroded region visually using 3-D VRML.

A Study on the Corrosion Behavior by the Moisture on the Surface Layer of the Al-Zn-Si ternary alloys (Al-Zn-Si 3원계 합금도금강판의 부식거동에 관한 연구)

  • 김영호;이상래;정원섭
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.3
    • /
    • pp.187-194
    • /
    • 2001
  • Galvalume sheet steel was developed recently, and is used widely in several fields. It has and had a good corrosion resistance in open atmosphere, but it has week corrosion resistance in the ambient surroundings of an airtight packing. Therefore, black patina was synthesized on the surface of Galvalume sheet steel. Corrosion by moisture on a Galvalume surface begins from edge of a droplet and proceeds to the center of droplet. It begins mainly on the interdendritic structure instead of dendritic structure. This suggests that corrosion by moisture occurs on the Zn shrinkage hole from rapid air cooling. In addition, the initial corrosion occurs by the local cell and continues by the oxygen concentration cell.

  • PDF

A Exprimental Study on the Corrosion of Reinforcing Steel in a Coastal Concrete Structure due to the Attack of Chloride Ions (염분침투에 의한 해안 콘크리트 구조물의 철근부식에 관한 실험적 연구)

  • 안상섭;김은겸;신치범;조원일;이윤한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.263-268
    • /
    • 1997
  • One of the principal causes of the deterioation of coastal concrete structures is the corrosion of reinforcing steel induced by the attack of chloride ions. An experimental study was performed to investigate the distribution of concentration of chloride ions in a coastal concrete structure and to measure the half-cell potential of embedded steel by using the copper-copper sulfate reference electrode. Quantitative analysis showed that the concentration of chloride ion in the aqueous phase near the surface of embedded steel exceeded a threshold value for corrosion, 0.05% by weight in concrete. The absolute value of half-cell potential at some members of embedded steel was measured to be higher than 350mV, indicating that the probability of corrosion is more than 90%. The prediction on corrosion based on the experimental measurements was confirmed by the observation of corrosion on the surface of steel bars in the concrete core taken out of the concrete structure.

  • PDF

Corrosion of Quartz Crystal Marine Sensors in Sea Water (항만센서용 수정진동자의 해수에 의한 부식)

  • 최광재;장상목;김영한
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.323-328
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 $\AA$ of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

  • PDF

Corrosion Characteristics of 316L Stainless Steel with Chloride Concentrations in Cathode Operating Conditions of Metallic Bipolar Plate for PEMFC (고분자 전해질 연료전지 금속분리판용 316L 스테인리스강의 양극작동조건에서 염화물 농도에 따른 부식 특성)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.435-450
    • /
    • 2021
  • The interest in eco-friendly energy is increasing, and polymer electrolyte membrane fuel cell (PEMFC) is attracting attention as alternative power sources. Research on metallic bipolar plates, a fuel cell component, is being actively conducted. However, since the operating conditions of PEMFC, in which sulfuric acid (H2SO4) and hydrofluoric acid (HF) are mixed, are strong acidity, the durability of the metallic bipolar plate is very important. In this research, the electrochemical characteristics and corrosion damage behavior of 316L stainless steel, a material for metallic bipolar plates, were analyzed through potentiostatic corrosion tests with test times and chloride concentrations. As the test times and chloride concentrations increased, the current density and corrosion damage increased. As a result of observation with scanning electron microscope(SEM) and 3D microscope, both the depth and width of pitting corrosion increased with increases in test times and chloride concentrations. In particular, the pitting corrosion damage depth at test conditions of 6 hours and 1000 ppm chloride increased the most. The growth of the pitting corrosion damage was not directly proportional to time and increased significantly after a certain period.

Corrosion in Batteries

  • Muniyandi, N.
    • Corrosion Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • A comprehensive coverage of corrosion in batteries is rendered difficult by the wide choice of materials, environments and physical features as obtained in practical settings. Understanding of the complex processes that occur in these electrochemical systems gets clearer as new theoretical approaches backed by sophisticated analytical and characterization techniques continue to provide valuable insights which aid in controlling/mitigating wasteful corrosion reactions which affect battery shelf-life, cycle life, rate capability and capacity. In the light of the above, I limit myself to a discussion on corrosion aspects in representative system such as conventional Leclanche, lead-acid battery and magnesium batteries, and advanced lithium systems.