Browse > Article
http://dx.doi.org/10.14773/cst.2018.17.3.129

Ti-6Al-4V Alloy Fabricated by Additive Manufacturing Method Using Micro-droplet Cell and Critical Pitting Temperature Techniques and Evaluation of its Resistance to Corrosion  

Seo, Dong-Il (School of Advanced Materials Engineering, Kookmin University)
Lee, Jae-Bong (School of Advanced Materials Engineering, Kookmin University)
Publication Information
Corrosion Science and Technology / v.17, no.3, 2018 , pp. 129-137 More about this Journal
Abstract
The resistance to corrosion of additive manufactured (3D printing) Ti-6Al-4V alloys was investigated using micro-electrochemical tests. In terms of corrosion resistance, the acicular martensitic ${\alpha}^{\prime}$ phase in such additive manufactured Ti-6Al-4V was the focus of attention, and its behavior was distinct from that of conventional subtractive manufactured Ti-6Al-4V. To order to identify ${\alpha}^{\prime}$ phase, XRD tests were performed and micro Vickers hardness was measured for different grains (bright and dark grains) in the additive manufactured Ti-6Al-4V alloy. Micro-electrochemical tests were performed to measure corrosion resistance of bright and dark grains in the additive manufactured Ti-6Al-4V alloy with specially designed electrochemical micro-droplet cell. Critical pitting temperature (CPT) measurement was performed to evaluate the resistance to pitting corrosion of additive manufactured Ti-6Al-4V alloys with different volumes of ${\alpha}^{\prime}$ phase and subtractive manufactured Ti-6Al-4V alloy. The dark grains of the laminated Ti-6Al-4V alloy distributed broader than the bright grains measured with low microhardness. The dark grains of the Ti-6Al-4V alloy, which was rich in martensite ${\alpha}^{\prime}$, had lower general corrosion and pitting resistance than bright grains. As the fraction of martensite ${\alpha}^{\prime}$ phase increased, the resistance to the pitting corrosion decreased.
Keywords
Additive manufacturing; Ti-6Al-4V; Corrosion Resistance; ${\alpha}^{\prime}$; Micro-droplet cell;
Citations & Related Records
연도 인용수 순위
  • Reference
1 B. Dutta and F. H. Froes, Adv. Mater. Res., 1019, 19 (2014).   DOI
2 W. D. Brewer, R. K. Bird, and T. A. Wallace, Mater. Sci. Eng. A, 243, 299 (1998).   DOI
3 G. He, J. Eckert, Q.L. Dai, M.L. Sui, W. Loser, M. Hagiwara. and E. Ma, Biomaterials, 24, 5115 (2003).   DOI
4 G. B. Cho, K.W. Kim, H. J. Ahn, K. K. Cho, and T. H. Nam, J. Alloys. Comp., 449, 317 (2008).   DOI
5 J. P. Kruth, G. Levy, F. Klocke, and T. H. C. Childs, Annals of the CIRP, 56, 730 (2007).   DOI
6 B. Vrancken, L. Thijs, J. P. Kruth, and J. V. Humbeeck, J. Alloys. Comp., 54, 177 (2012).
7 N. Dai, L. C. Zhang, J. Zhang, Q. Chen, and M. Wu, Corros. Sci., 102, 484 (2016).   DOI
8 L. Thijs, F. Verhaeghe, T. Craeghs, J. V. Humbeeck, and J. P. Kruth, Acta Mater., 58, 3303 (2010).   DOI
9 R. Boyer, E. W. Collings, and G. Welsch, Materials properties handbook: Titanium alloys, pp. 1-1169, ASM International, Ohio (1994).
10 E. Sallica-Leva, A. L. Jardini, and J. B. Fogagnolo, J. Mech. Behav. Biomed. Mater., 26, 98 (2013).   DOI
11 J. J. Kim and J. B. Lee, J. Kor. Inst. Met. Mater., 46, 809 (2008).
12 C.-J. Park, H.-S. Kwon, and M. M, Lohrengel, Mater. Sci. Eng. A., 372, 180 (2004).   DOI
13 ASTM G150-13, Standard Test Method for Electrochemical Critical Pitting Temperature Testing of Stainless Steels (2013).