• Title/Summary/Keyword: Correlation Detection

Search Result 1,739, Processing Time 0.038 seconds

Detection of Dopamine and Serotonin by Competitive Enzyme-Linked Immunosorbent Assay (경쟁적 ELISA를 이용한 도파민과 세로토닌의 검출)

  • Namkung, Su Min;Choi, Jeong Su;Park, Ji Hyang;Yang, Man Gil;Lee, Min Woo;Kim, Suhng Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.220-226
    • /
    • 2017
  • Dopamine (DA) and serotonin (5-Hydroxytryptamine, 5-HT) are neurotransmitters and hormones that exist in small amounts but have important role in the body. Serum and 24-hour urine are used as specimens, and are usually examined by HPLC-MS. In this study, we tried to detect DA and 5-HT by competitive ELISA using antigen-antibody (Ab) reaction. After immobilizing $5{\mu}g/mL$ BSA conjugate on a 96-well surface, hormone and primary Ab, which are respectively diluted to different concentrations, were treated. Then, HRP-conjugated secondary Ab and TMB were added to measure absorbance. The regression equation and $R^2$ value were calculated based on absorbance, and sensitivity of Ab to hormone as well as the correlation between hormone concentration and absorbance were determined. In DA ELISA, $R^2$, the correlation between the concentration of hormone and absorbance, was the highest by 0.91 when anti-dopamine Ab was diluted 6,000 times and 7,000 times. In 5-HT ELISA, $R^2$ was bigger than 0.90 in every concentration except 3,000 times and 6,000 times. Both DA and 5-HT were not effectively detected at low concentrations (less than $1.0{\times}10^{-7}M$); and because reference value of serum DA is lower than this, HPLC-MS was required to detect serum DA. However, competitive ELISA may be effective in detecting 24-hour urine DA, serum, and 24-hour 5-HT. Further studies are needed to detect hormones more accurately at lower concentrations.

Detecting Phenology Using MODIS Vegetation Indices and Forest Type Map in South Korea (MODIS 식생지수와 임상도를 활용한 산림 식물계절 분석)

  • Lee, Bora;Kim, Eunsook;Lee, Jisun;Chung, Jae-Min;Lim, Jong-Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.267-282
    • /
    • 2018
  • Despite the continuous development of phenology detection studies using satellite imagery, verification through comparison with the field observed data is insufficient. Especially, in the case of Korean forests patching in various forms, it is difficult to estimate the start of season (SOS) by using only satellite images due to resolution difference. To improve the accuracy of vegetation phenology estimation, this study reconstructed the large scaled forest type map (1:5,000) with MODIS pixel resolution and produced time series vegetation phenology curves from Normalized Difference Vegetation Index (NDVI) and Enhanced Vegetation Index (EVI) derived from MODIS images. Based on the field observed data, extraction methods for the vegetation indices and SOS for Korean forests were compared and evaluated. We also analyzed the correlation between the composition ratio of forest types in each pixel and phenology extraction from the vegetation indices. When we compared NDVI and EVI with the field observed SOS data from the Korea National Arboretum, EVI was more accurate for Korean forests, and the first derivative was most suitable for extracting SOS in the phenology curve from the vegetation index. When the eight pixels neighboring the pixels of 7 broadleaved trees with field SOS data (center pixel) were compared to field SOS, the forest types of the best pixels with the highest correlation with the field data were deciduous forest by 67.9%, coniferous forest by 14.3%, and mixed forest by 7.7%, and the mean coefficient of determination ($R^2$) was 0.64. The average national SOS extracted from MODIS EVI were DOY 112.9 in 2014 at the earliest and DOY 129.1 in 2010 at the latest, which is about 0.16 days faster since 2003. In future research, it is necessary to expand the analysis of deciduous and mixed forests' SOS into the extraction of coniferous forest's SOS in order to understand the various climate and geomorphic factors. As such, comprehensive study should be carried out considering the diversity of forest ecosystems in Korea.

Assessment of Clinical Applicability of a New Plaque Scoring System Using Quantitative Light-Induced Fluorescence-Digital (Quantitative Light-Induced Fluorescence-Digital을 이용한 치면세균막 검사법의 임상적 활용 가능성 평가)

  • Hwang, Hye-Rim;Cho, Young-Sik;Kim, Baek-Il
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.150-157
    • /
    • 2014
  • The aim of this study was to suggest a convenient method of monitoring the gingival state through plaque detection. Quantitative Light-Induced Fluorescence-Digital (QLF-D), which can assess mature plaque, can be used to assess the oral hygiene status of individuals and to establish an adequate intervention plans for them. The subjects of the study participated in the clinical training at Department of Dental Hygiene, N University. The subjects completed questionnaires on general characteristics and oral hygiene methods. Then, photographs of maxillary and mandibular anterior teeth of the subjects were taken using the QLF-D. After the oral examinations, gingival state was recorded according to the $L{\ddot{o}}e$ & Silness's Gingival Index (GI). In addition, a plaque control record was calculated in percentage using disclosing agent. The analysis of the relation between the plaque control record and the QLF-D scores showed positive correlation (r=0.638, p<0.001), and the analysis of the relation between the QLF-D scores and the gingival bleeding index scores also showed positive correlation (r=0.562, p<0.001). Besides, the study classified the participants into healthy gingiva group and the gingivitis group according to the classification criteria of GI, and when the difference of QLF-D scores between the groups was analyzed, the QLF-D scores were statistically significantly higher (t=-2.785, p=0.007) in the gingivitis group ($1.71{\pm}1.545$) than the healthy gingiva group ($0.74{\pm}1.290$). When the differences in mean values of the QLF-D scores were analyzed against and the gingival bleeding index scores, the QLF-D scores of 0 and 1 belonged to the category of normal gingival state while the QLF-D scores of 2, 3 and 4 belonged to the category of gingivitis state. Therefore, it is deemed that the red fluorescence detected by the QLF-D from the mature supragingival plaque can be used for monitoring the state of gingivitis.

Cellular Analysis and Measurement of Mucin in Sputum of Chronic Airway Disease (만성기도질환의 객담세포분석과 mucin의 측정)

  • Kim, Ki-Up;Kim, Yang-Ki;Shin, Chan-Young;Kim, Do-Jin;Uh, Soo-Taek;Kim, Yong-Hoon;Ko, Kwang-Ho;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.82-92
    • /
    • 2000
  • Background : In chronic airway disease, mucus secretion is increased, but extraction of mucin, which is the main component of mucus secretion, is a very complicated and limited in clinical use. Recently, monoclonal antibody for mucin was developed for possible clinical use. In this study, cellular analysis and quantification of respiratory mucin in sputum of patients with chronic airway diseases were performed. Method : Sputum was collected from patients with asthma(n=33), bronchiectasis(n=8) or chronic bronchitis (n=13) by spontaneous expectoration or by hypertonic saline induction. Collected sputums was treated by 0.1% dithiotreitol to dissociate the disulfide bond of the mucus and filtered through a nylon gauze. Total cell count, viability and differential count were measured. For detection of mucin, collected samples were treated with sodium dodecyl sulfate polyacrylamide gel electrophoresis and then with monoclonal antibody(HMO2), as the primary antibody, and PAS stain. The amount of mucin was measured with ELISA by HMO2. Correlation with clinical information, cellular analysis, and amount of measured mucin were analyzed. Results : Total cell counts of sputum were significantly increased in patients with bronchiectasis but viability remained the same. Eosinophils were significantly increased in patients with asthma, neutrophils in bronchiectasis chronic bronchitis, respectively (p<0.05). The results of Western blotting and PAS staining confirmed the presence of glycoproteins and matched? with mucin. The amounts of mucin measured by ELISA were not significantly different among the disease groups. Significant correlation was identified between the amount of mucin and viability(r=-0.482, p<0.05). Conclusion : Inflammatory cells in the sputum of those with chronic airway disease were different for each disease type. Measurement of mucin by ELISA via monoclonal antibodies may be a simple method for the evaluation of chronic airway disease.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Rice Blast Control and Race Diversity by Mixed-Planting of Two Cultivars ('Hopyeongbyeo'/'Nampyeongbyeo') with Different Susceptibility to Magnaporthe oryzae (호평벼와 남평벼의 혼합재배에 의한 도열병 방제와 레이스 다양성의 변화)

  • Oh, In-Seok;Min, Ji-Young;Cho, Myung-Gil;Roh, Jae-Hwan;Shin, Dong-Bum;Song, Jin;Kim, Myeong-Ki;Cho, Young-Chan;Kim, Byung-Ryun;Han, Seong-Sook
    • Research in Plant Disease
    • /
    • v.14 no.3
    • /
    • pp.143-152
    • /
    • 2008
  • Mixed-planting of two rice cultivars, HP ('Hopyeongbyeo') and NP ('Nampyeongbyeo'), having a dissimilar susceptibility to rice blast was practiced for chemical-free control of rice blast in the field. The HP/NP combination was selected for applying under mechanized agricultural conditions. Because they have similar genetic characteristics such as seed germination and heading time, culm length, rice quality and size of rice grains except susceptibility to blast. Incidence of panicle blast was reduced 50.4 % compare with supposed blast incidence by HP/NP mixed-planting when the seeds of two cultivars were combined 1 to 1 as weight. Supposed blast incidence was estimated from reduction of rice blast caused by addition of a resistant cultivar NP. Race diversity of Magnaporthe oryzae was examined for correlation with control effect of HP/NP mixed-planting on rice blast. The population of dominant race KJ-101 was diminished and replaced with various co-existing races and eleven new races were appeared in mixed-planting plot. Total number of race isolated from mixed-planting plot was not largely different from mono-culture. However, detection frequency of the new race was increased and variation of the population size of each race was decreased in mixed-planting plots. It was shown that a biased community with a dominant race (KJ-101 or KI-181) was altered to a balanced one of coexisting races. From these results, it was supposed that the balanced diversity among co-existing races within a community might be correlated to control effect by HP/NP mixed-planting on rice blast. Further more, it should be studied that genetic characteristics of the individual race including a virulence on cv. HP and NP was examined for verifying a correlation of mixed-planting effect and race diversity.

Interobserver Reproducibility of Segmental Scoring of $^{99m}Tc$-MIBI Myocardial SPECT ($^{99m}Tc$-MIBI 심근 SPECT의 분절 육안 분석시 판독자간의 일치도)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Lee, Kyung-Han;Kim, Jong-Ho;Shon, Kyung-Soo;Cho, Sung-Wook;Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul;Seo, Jeong-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.317-325
    • /
    • 1994
  • The accuracy of dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial imaging for detection of ischemia depends on reproducible image interpretation. To evaluate the reproducibility of visual assessment, agreement in interpretation among two independent observers, blind-ed to clinical data, was evaluated in SPECT images of 131 patients (94 males, 38 females; mean age $58{\pm}7yr$) with suspected coronary artery disease who underwent both dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial SPECT and coronary angiography. The left ventricle was divided into twenty-nine segments in stress and rest SPECT images and each segment was visually graded according to a five-point scale (segmental score : 0=normal, 1=equivocal, 2=mild decrease, 3=severe decrease and 4=absent uptake). Overall concordance of segmental scoring between the two observers was 80%. The Pear-son's correlation coefficient (r) of the segmental scores for stress and rest images were 0.67 and 0.65, respectively, while the difference in score between the two images showed a correlation of 0.45 (all p<0.001). Agreement between two observers in final SPECT diagnosis as absence or presence of disease was 93%. The degree of agreement in segmental scoring showed no difference between patients with or without agreement as to the presence of disease. Therefore it appeared that cases with inconcordant diagnosis between the 2 observers were mainly due to a difference in individual threshold for interpretating the significance of a particular decreased uptake area rather than to a difference in perceiving the degree of the hypoactivity Thus, establishment of individual optimum thresholds in visual interpretation of myocardial SPECT may be helpful to improve reproducibility and accuracy of scan diagnosis.

  • PDF

Comparative Quantitative Study of Surfactant Protein C mRNA by Filter Hybridization and Solution Hybridization in Rats (Filter Hybridization과 Solution Hybridization 방법에 의한 백서 Surfactant Protein C mRNA 정량측정의 비교)

  • Kim, Jin-Ho;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.517-529
    • /
    • 2001
  • Background : Surfactant protein C(SP-C) is a hydrophobic 5,000 dalton molecule. SP-C has the primary roles in accelerating surface spreading of a surfactant phospholipid. The filter hybridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. Methods : The authors measured the SP-C mRNA levels quantitatively using solution hybridization and filter hybridization assays to obtain a standard curve equation to quantify the mRNA of unknown samples comparatively. Results : 1. The minimum level of the specimens by solution hybridization was 3 pg for SP-C mRNA. 2. The standard curve equation of the solution hybridization assay between the counts per minute(Y) and the SP-C mRNA transcript input(X) was Y=6.46 X+244. The correlation coefficient was 0.99. 3. The minimum detection level of specimens by filter hybridization was 0.1 ng for SP-C mRNA. 4. The standard curve equation of the filter hybridization assay between the counts per minute(Y) and SP-C mRNA transcript input(X) is Y=2541.6 X+252.7. The correlation coefficient was 0.99. Conclusions : A comparison of CPM/filter in the linear range allowed an accurate and reproducible estimation of the SP-C mRNA copy number. Filter hybridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. It is ideally suited to situations where accurate quantitation of multiple samples is required.

  • PDF

The Non-Destructive Determination of Heavy Metals in Welding Fume by EDXRF (EDXRF에 의한 용접흄 중의 중금속의 비파괴 정량)

  • Park, Seunghyun;Jeong, Jee Yeon;Ryoo, Jang Jin;Lee, Naroo;Yu, Il Je;Song, Kyung Seuk;Lee, Yong Hag;Han, Jeong Hee;Kim, Sung Jin;Park, Jung sun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.229-234
    • /
    • 2001
  • The EDXRF(Energy Dispersive X-ray Fluorescence Spectrometer) technique was applied to the determination of heavy metals in welding fume. The EDXRF method designed in this study was a non-destructive analysis method. Samples were analyzed directly by EDXRF without any pre-treatment such as digestion and dilution. The samples used to evaluate this method were laboratory samples exposed in a chamber connected with a welding fume generator. The samples were first analyzed using a non-destructive EDXRF method. The samples subsequently were analyzed using AAS method to verify accuray of the EDXRF method. The purpose of this study was to evaluate the possibility of the non-destructive analysis of heavy metals in welding fume by EDXRF. The results of this study were as follow: 1.When the samples were collected under the open-face sampling condition, a surface distribution of welding fume particles on sample filters was uniform, which made non-destructive analysis possible. 2. The method was statistically evaluated according to the NIOSH(National Institute for Occupational Safety and Health) and HSE(Health and Safety Executive) method. 3. The overall precision of the EDXRF method Was calculated at 3.45 % for Cr, 2.57 % for Fe and 3.78 % for Mn as relative standard deviation(RSD), respectively. The limits of detection were calculated at $0.46{\mu}g$/sample for Cr, $0.20{\mu}g$/sample for Fe and $1.14{\mu}g$/sample for Mn, respectively. 4. A comparison between the results of Cr, Fe, Mn analyzed by EDXRF and AAS was made in order to assess the accuracy of EDXRF method. The correlation coefficient between the results of EDXRF and AAS was 0.9985 for Cr, 0.9995 for Fe and 0.9982 for Mn, respectively. The overall uncertainty was determined to be ${\pm}12.31%$, 8.64 % and 11.91 % for Cr, Fe and Mn, respectively. In conclusion, this study showed that Cr, Fe, Mn in welding fume were successfully analyzed by the EDXRF without any sample pre-treatment such as digestion and dilution and a good correlation between the results of EDXRF and AAS was obtained. It was thus possible to use the EDXRF technique as an analysis method of working environment samples. The EDXRF method was an efficient method in a non-destructive analysis of heavy metals in welding fume.

  • PDF