• Title/Summary/Keyword: Correlation Between Water Quality

Search Result 501, Processing Time 0.023 seconds

Analysis of Meteorological Features and Prediction Probability Associated with the Fog Occurrence at Chuncheon (춘천의 안개발생과 관련된 기상특성분석 및 수치모의)

  • Lee Hwa Woon;Lee Kwi Ok;Baek Seung-Joo;Kim Dong Hyeok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.303-313
    • /
    • 2005
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years $(2000\~2003)$ data at Chuncheon and the probability of prediction is investigated. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for $2\~4$ hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1m/s. Especially, about $42\%$ of foggy day fell on the calm $(0\~0.2\;ms^{-1})$ conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water surface temperature was calculated by using Water Quality River Reservoir System (WQRRS) and then it was used as the surface boundary condition of MM5. The numerical experiment was carried out for 2 days from 1300 LST on 14 October 2003 to 1300 LST on 16 October 2003 and fog was simulated at dawn on 15 and 16 October 2003. Simulated air temperature and dew point temperature indicate the similar tendency to observation and the simulated difference between air temperature and dew point temperature has also the similar tendency within $2^{\circ}C$. Thus, the occurrence of fog is well simulated in the terms of the difference between air temperature and dew point temperature. Horizontal distribution of the difference between air temperature and dew point temperature from the numerical experiment indicates occurrence, dissipation and lasting time of fog at Chuncheon. In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

A Study on Seasonal Pollutant Distribution Characteristics of Contaminated Tributaries in Nakdong River Basin (낙동강 중점관리지류·지천의 계절적 오염발생특성 분석)

  • Na, Seungmin;Kwon, Heongak;Shin, Sang Min;Son, YoungGyu;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.301-312
    • /
    • 2016
  • This study has performed comparative analysis on characteristics of contaminated 35 tributaries on seasonal variation/point discharge load/pollutant distribution of water quality factors(8) in order to understand the effect of the watershed in Nakdong River Basin. As a results, the water quality of $BOD_5$(Biochemical Oxygen Demand), Chl-a(Chlorophyll a) and Fecal E. Coli shows II grade at tributaries of more than 50% without COD(Chemical Oxygen Demand), TP(Total Phosphate), TOC(Total Oxygen Carbon) and TN(Total Nitrogen) factors. The specific discharge(Q) were occupied about 54.4% (19 sites) as $0.05m^3/sec/km^2$ value. Among these results, the contaminant level of Dalseocheon, Hyeonjicheon, Seokkyocheon 1, Uriyeongcheon and Dasancheon was also high, which has to consider a discharged pollutant load(kg/day). The 35 major tributaries of Nakdong River were included in 7 mid-watershed, such as Nakdong Waegwan, Geumho River, Nakdong Goryung, Nakdong Changnyung, Nam River, Nakdong Milyang, Nakdong River Hagueon. Especially, the discharged pollutant load of Nam River and Geumho River also was high according to the amount of discharge such as Kachang dam, Gongsan dam and Nam river dam. Seasonal difference of the water quality factors such as $BOD_5$, TN, SS and Q was observed largely, on the other hand the TP and Chl-a was not. This is guessed due to the precipitation effect of site, biological and physicochemical degradation properties of pollutant and etc. The co-relationship between the seasonal difference and water quality factors was observed using a Pearson correlation coefficients. Besides, the Multiple Regression analysis using a Stepwise Regression method was conducted to understand the effect between seasonal difference and water quality factors/regression equations. As a result, the Multiple Regression analysis was adapted in the spring, summer and autumn without the winter, which was observed high at spring, summer and autumn in the order COD/TP, Chl-a/TOC, TOC/COD/$BOD_5$ water quality factors, respectively.

A Study on the Discharged Characteristics of the Pollutants using the Empirical Equation and Factor Analysis - Case Study of the Upper and Lower Watershed of South Han River (경험식과 요인분석을 통한 오염물질 유출 특성 연구 - 남한강 상·하류 수계 주요 하천을 중심으로)

  • Park, Ji Hyoung;Sohn, Su Min;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.905-913
    • /
    • 2011
  • This study was conducted to characterize the discharge feature of pollutant load from the upper and lower watershed influencing on the water quality of South Han River using the empirical equation and Factor Analysis. The results of regression analysis between flow rate and pollutant load were as follows. In the streams of the upper watershed of South Han river, $BOD_5$ and $COD_{Mn}$ were increased as the flow rate was increased. Also, steep increases in SS and TP were observed with positive correlation with the flow rate while change in TN was slightly shown. On the other hand, in the streams of the lower watershed of South Han river, $BOD_5$ was negatively correlated with the flow rate, being decreased with the increase in the flow rate. However, changes in $COD_{Mn}$, TN, SS, and TP showed a similar trend with those observed in the upper watershed. With Factor Analysis of the water quality and various components, it was appeared that the flow rate, SS, and TP were significantly correlated each other and they were indicated as the principal component influencing on water quality in the streams of the upper watershed. In contrast, $BOD_5$, $COD_{Mn}$ and TOC were significantly correlated each other and they were included as the principal pollution component of the streams in the lower watershed. From these results, it was conclusive that the upper watershed of South Han River was mainly affected by non point source pollutants while the lower watershed was influenced by point source pollutants from the developed areas.

Eco-environmental assessment in the Sembilan Archipelago, Indonesia: its relation to the abundance of humphead wrasse and coral reef fish composition

  • Amran Ronny Syam;Mujiyanto;Arip Rahman;Imam Taukhid;Masayu Rahmia Anwar Putri;Andri Warsa;Lismining Pujiyani Astuti;Sri Endah Purnamaningtyas;Didik Wahju Hendro Tjahjo;Yosmaniar;Umi Chodrijah;Dini Purbani;Adriani Sri Nastiti;Ngurah Nyoman Wiadnyana;Krismono;Sri Turni Hartati;Mahiswara;Safar Dody;Murdinah;Husnah;Ulung Jantama Wisha
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.12
    • /
    • pp.738-751
    • /
    • 2023
  • The Sembilan Archipelago is famous for its great biodiversity, in which the humphead wrasse (Cheilinus undulatus) (locally named Napoleon fish) is the primary commodity (economically important), and currently, the environmental degradation occurs due to anthropogenic activities. This study aimed to examine the eco-environmental parameters and assess their influence on the abundance of humphead wrasse and other coral reef fish compositions in the Sembilan Archipelago. Direct field monitoring was performed using a visual census throughout an approximately one km transect. Coral cover data collection and assessment were also carried out. A coastal water quality index (CWQI) was used to assess the water quality status. Furthermore, statistical-based analyses [hierarchical clustering, Pearson's correlation, principal component analysis (PCA), and canonical correspondence analysis (CCA)] were performed to examine the correlation between eco-environmental parameters. The Napoleon fish was only found at stations 1 and 2, with a density of about 3.8 Ind/ha, aligning with the dominant composition of the family Serranidae (covering more than 15% of the total community) and coinciding with the higher coral mortality and lower reef fish abundance. The coral reef conditions were generally ideal for supporting marine life, with a living coral percentage of about > 50% in all stations. Based on CWQI, the study area is categorized as good and excellent water quality. Of the 60 parameter values examined, the phytoplankton abundance, Napoleon fish, and temperature are highly correlated, with a correlation coefficient value greater than 0.7, and statistically significant (F < 0.05). Although the adaptation of reef fish to water quality parameters varies greatly, the most influential parameters in shaping their composition in the study area are living corals, nitrites, ammonia, larval abundance, and temperature.

Nonlinear correlation analysis between air and water temperatures in the coastal zone, Korea (우리나라 연안 기온과 수온의 비선형 상관관계 분석)

  • Lee, Khil-Ha
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.2
    • /
    • pp.128-135
    • /
    • 2007
  • In response to anthropogenic global warming due to a buildup greenhouse gas, the effect of the air temperature on water temperature has been noticed. Therefore, effects have been made to build an air/water temperature relationship at three study regions using the data collected by the Ministry of the Maritime Affairs and Fisheries (MOMAF). The air/water relationship varies with time-scale and weekly time-scale was chosen for the study. The data were fitted to the S-shaped non-linear relationship, and the parameters for the S-curve were derived using a single-criteria multi-parameter optimization scheme. Separate regression curves were fitted to consider seasonal hysteresis at the Masan site. The study results support the S-shaped non-linear relationship is the best fit for the air/water relationship at the Korean coastal zone. This study will contribute to determine the future policy regarding water quality and ecosystem for the decision-driving organization.

Distribution of THMs at Drinking Water Purification Plants in the East Coast Region of Gangwon-do (강원도 동해안 지역 정수장의 THMs 분포)

  • Huh, In-Ryang;Shin, Yong-Keon;Park, Sung-Bin;Lee, Teak-Soo;Shim, Tae-Heum
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2013
  • Objectives: In an effort to examine the distribution of THMs (Trihalomethane) generated from chlorine disinfection by the drinking water treatment plants located on the east coast region of Gangwon-do, this study surveyed the distribution and concentrations of each component of THMs twice per month for 5 years from 2008 to 2012. Fluctuation pattern in the seasonal generation amount was identified. In addition, the correlation between the concentration of organic substances in water and THMs was assessed, along with stability of purified water quality supplied by the water treatment plants on the east coast by analyzing the composition ratio of each component that constitutes THMs and the detection frequency. Method: The research was done on purified water supplied by 29 water treatment plants in 7 cities and counties (Goseong-gun, Sokcho-si, Yangyang-gun, Gangneung-si, Donghae-si, Samcheok-si, Taebaek-si) located in Gangwon-do on the east coast. Water samples were collected twice a month from 2008 to 2012 and were investigate for chloroform, bromodichloromethane (BDCM), dibromochloromethane (DBCM), and bromoform, based on analysis through Purge-Trap (Tekmar 3000) devices using FID-attached GC (HP 6890, Hewlett Packard). Result: THMs concentration detected at Gangneung-si was 0.0086mg/L, Goseong-gun 0.0019mg/L, Donghae-si 0.0099 mg/L, Samcheok-si 0.0016 mg/L, Sokcho-si 0.0057 mg/L, Yangyang-gun 0.0027 mg/L and Taebaek-si 0.0038 mg/L. As the THMs composition rate, chloroform constitutes 51.4% followed bybromodichloromethane 22.3%, bromoform 15.2% and dibromochloromethane 11.1% respectively. Conclusion: Throughout the entire THMs survey areas and period, the maximum concentration was 0.072mg/L, which did not exceed the water quality standards (0.1 mg/L), and the overall average concentration was very low at 0.0044 mg/L.

The Effect of Antecedent Moisture Conditions on the Contributions of Runoff Components to Stormflow in the Coniferous Forest Catchment

  • Choi, Hyung-Tae;Kim, Kyong-Ha;Lee, Choong-Hwa
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.5
    • /
    • pp.755-761
    • /
    • 2010
  • This study analyzed water quality data from a coniferous forest catchment in order to quantify the contributions of runoff components to stormflow, and to understand the effects of antecedent moisture conditions within catchment on the contributions of runoff components. Hydrograph separation by the twocomponent mixing model analysis was used to partition stormflow discharge into pre-event and event components for total 10 events in 2005 and 2008. To simplify the analysis, this study used single geochemical tracer with Na+. The result shows that the average contributions of event water and pre-event water were 34.8% and 65.2% of total stormflow of all 10 events, respectively. The event water contributions for each event varied from 18.8% to 47.9%. As the results of correlation analysis between event water contributions versus some storm event characteristics, 10 day antecedent rainfall and 1 day antecedent streamflow are significantly correlated with event water contributions. These results can provide insight which will contribute to understand the importance of antecedent moisture conditions in the generation of event water, and be used basic information to stormflow generation process in forest catchment.

An Application of Toxicity Test to Water Management and Water Treatment (수질관리와 수처리에의 독성시험의 응용)

  • Kim, Berm-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2005
  • In this research, we tried to develop the application method to water management and treatment using toxicity test method. When we measure the toxicity of environmental samples, we have to decide whether we take some countermeasures to reduce the toxicity or not. The first issue is how to set these action levels in each bioassays. A new idea was attempted to authorize indirect approach of each bioassays through the response characteristics against mixture of chemicals in water quality standard. The significant response in the cell-growth-inhibition bioassay was detected for standards-mixture(STDs). For acute toxicity assay, STDs-based implicit correlation between risks to humans and bioassay data showed a rational approach to set action levels in practical management. A simple model was proposed to describe and predict the changes in the total toxicity based on the concentrations of toxic-controlling chemicals during the ozonation of landfill leachates. On the basis of this simple model, toxicity reduction was predicted for pre-aggregation treatment before ozonation and ozone concentration during the ozonation. The method proposed in this study would be useful in optimizing water treatment processes and their running conditions in terms of the toxicity reduction efficacy.

Correlation between Shear Force and Grade Decision Factors on Hanwoo Cow Carcass (소 도체등급 판정 항목과 전단력과의 상관관계)

  • Kim, Dong-Yeop;Kim, Byoeng-Do;Baek, Sang-Guk;Jeong, Hyeong-Jin;Kim, Dae-Gon;Han, Gi-Dong
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.344-348
    • /
    • 2008
  • This study was carried out to evaluate the correlation between shear force determined by tenderness analyzer and grade decision factors consisting of yield grade (carcass weight, ribeye area, backfat thickness) and quality grade (meat color, fat color, marbling, maturity, texture) in a total of 200 Hanwoo cows. Results showed that there was a negative correlation between shear force and yield grade (r=-0.186, p<0.01), i.e., when the grade of carcass yield increased (A score), the shear force value decreased. Shear force scores showed a significant correlation with marbling scores (r=-0.19, p<0.01), but no correlation with scores of meat color, fat color and texture. The maturity of Hanwoo cows is known to be one of the major factors for evaluating the grade, and the maturity showed no significant correlation with shear force value (r=-0.05, p>0.05). It is possible to get useful information for evaluating the grade of Hanwoo cows if further studies addressing the correlation of water holding capacity, juiciness, taste and overall acceptability with maturity are carried out.

Quality Characteristics of Noodles Prepared with Pine Needle powder and extract during Storage (솔잎 분말과 추출물 첨가 국수의 품질특성과 저장성)

  • Jeon, Jeong-Ryae;Kim, Hyang-Hee;Park, Geum-Soon
    • Korean journal of food and cookery science
    • /
    • v.21 no.5
    • /
    • pp.685-692
    • /
    • 2005
  • This study summarizes our findings on the effect of pine needle powder and water extract on the quality characteristics of wet noodle and the changes of microbial count during storage. The lightness of wet noodles was significantly decreased with increasing amounts of PN powder and water extract added in the noodles(p<.001), whereas the redness and yellowness of the noodles were significantly increased(p<.001). Texture evaluation showed that springiness was the highest in the noodle prepared with 5% PN extract, whereas brittleness was the lowest in 1% PN extract. At the beginning period of storage, there were significant differences of microbial cell count in PCA and PDA among the samples, but a significant decreasing was observed after 6 days. In the relationship between sensory and mechanical properties, a negative correlation was observed between color and sleekness, while there was a positive correlation with redness and yellowness. Sensory evaluation showed that odor, taste, texture and overall acceptability were the best in noodles processed with 3% PN extract.