• Title/Summary/Keyword: Corpectomy

Search Result 48, Processing Time 0.025 seconds

Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

  • Park, Sung Bae;Kim, Ki Jeong;Han, Sanghyun;Oh, Sohee;Kim, Chi Heon;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.415-423
    • /
    • 2018
  • Objective : To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods : We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results : There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion : When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

The Mechanical Effect of Rod Contouring on Rod-Screw System Strength in Spine Fixation

  • Acar, Nihat;Karakasli, Ahmet;Karaarslan, Ahmet A.;Ozcanhan, Mehmet Hilal;Ertem, Fatih;Erduran, Mehmet
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.425-429
    • /
    • 2016
  • Objective : Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, $20^{\circ}$ kyphotic, and $20^{\circ}$ lordotic rod contouring on rod-screw fixation systems, by forming a corpectomy model. Methods : The corpectomy groups were prepared using ultra-high molecular weight polyethylene samples. Non-destructive loads were applied during flexion/extension and torsion testing. Spine-loading conditions were simulated by load subjections of 100 N with a velocity of $5mm\;min^{-1}$, to ensure 8.4-Nm moment. For torsional loading, the corpectomy models were subjected to rotational displacement of $0.5^{\circ}\;s^{-1}$ to an end point of $5.0^{\circ}$, in a torsion testing machine. Results : Under both flexion and extension loading conditions the stiffness values for the lordotic rod-screw system were the highest. Under torsional loading conditions, the lordotic rod-screw system exhibited the highest torsional rigidity. Conclusion : We concluded that the lordotic rod-screw system was the most rigid among the systems tested and the risk of rod and screw failure is much higher in the kyphotic rod-screw systems. Further biomechanical studies should be attempted to compare between different rod kyphotic angles to minimize the kyphotic rod failure rate and to offer a more stable and rigid rod-screw construct models for surgical application in the kyphotic vertebrae.

Clinical Significance of Radiological Stability in Reconstructed Thoracic and Lumbar Spine Following Vertebral Body Resection

  • Sung, Sang-Hyun;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2014
  • Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.

Surgical Reconstruction Using a Flanged Mesh Cage without Plating for Cervical Spondylotic Myelopathy and a Symptomatic Ossified Posterior Longitudinal Ligament

  • Kang, Jung Hoon;Im, Soo-Bin;Yang, Sang-Mi;Chung, Moonyoung;Jeong, Je Hoon;Kim, Bum-Tae;Hwang, Sun-Chul;Shin, Dong-Seong;Park, Jong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.671-680
    • /
    • 2019
  • Objective : We introduce innovative method of cervical column reconstruction and performed the reconstruction with a flanged titanium mesh cage (TMC) instead of a plate after anterior corpectomy for cervical spondylotic myelopathy (CSM) and an ossified posterior longitudinal ligament (OPLL). Methods : Fifty patients with CSM or OPLL who underwent anterior cervical reconstruction with a flanged TMC were investigated retrospectively. Odom's criteria were used to assess the clinical outcomes. The radiographic evaluation included TMC subsidence, fusion status, and interbody height. Thirty-eight patients underwent single-level and 12 patients underwent two-level corpectomy with a mean follow-up period of 16.8 months. Results : In all, 19 patients (38%) had excellent outcomes and 25 patients (50%) had good outcomes. Two patients (4%) in whom C5 palsy occurred were categorized as poor. The fusion rate at the last follow-up was 98%, and the severe subsidence rate was 34%. No differences in subsidence were observed among Odom's criteria or between the single-level and two-level corpectomy groups. Conclusion : The satisfactory outcomes in this study indicate that the flanged TMC is an effective graft for cervical reconstruction.

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases : Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation

  • Kim, Min-Ki;Kim, Sung-Min;Jeon, Kwang-Mo;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.135-140
    • /
    • 2012
  • Objective : To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods: The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results: Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion: ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH.

Analysis of Prognostic Factors Relating to Postoperative Survival in Spinal Metastases

  • Yang, Soon-Bum;Cho, Won-Ik;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.127-134
    • /
    • 2012
  • Objective: To analyze the prognostic factors thought to be related with survival time after a spinal metastasis operation. Methods: We retrospectively analyzed 217 patients who underwent spinal metastasis operations in our hospital from 2001 to 2009. Hematological malignancies, such as multiple myeloma and lymphoma, were excluded. The factors thought to be related with postoperative survival time were gender, age (below 55, above 56), primary tumor growth rate (slow, moderate, rapid group), spinal location (cervical, thoracic, and lumbo-sacral spine), the timing of radiation therapy (preoperative, postoperative, no radiation), operation type (decompressive laminectomy with or without posterior fixation, corpectomy with anterior fusion, corpectomy with posterior fixation), preoperative systemic condition (below 5 points, above 6 points classified by Tomita scoring), pre- and postoperative ambulatory function (ambulatory, non-ambulatory), number of spinal metastases (single, multiple), time to spinal metastasis from the primary cancer diagnosis (below 21 months, above 22 months), and postoperative complication. Results: The study cohort mean age at the time of surgery was 55.5 years. The median survival time after spinal operation and spinal metastasis diagnosis were 6.0 and 9.0 months. In univariate analysis, factors such as gender, primary tumor growth rate, preoperative systemic condition, and preoperative and postoperative ambulatory status were shown to be related to postoperative survival. In multivariate analysis, statistically significant factors were preoperative systemic condition (p=0.048) and postoperative ambulatory status (p<0.001). The other factors had no statistical significance. Conclusion: The factors predictive for postoperative survival time should be considered in the surgery of spinal metastasis patients.

Extended Posterolateral Thoracotomy for "Dumbbell" Mediastinal Tumor -Report of 3 Cases- (광범위후외측개흉술에 의한 "Dumbbell" 종격동종양수술지험 -3례 보고-)

  • Oh, Bong-Suk;Kim, In-Gwang;Kim, Su-Han;Jeong, Jae-Yoon
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1071-1074
    • /
    • 1995
  • Approximately 9.8% of neurogenic tumors of the mediastinum extend into the spinal column so that the composite neoplastic mass was dumbbell shaped. We experienced three patients confirmed by Dumbbell shaped mediastinal tumor radiologically and tried surgical resection by posterolateral thoracotomy only corpectomy and costotransversectomy was performed simultaneously in three patients and interbody fusion in two. In one patient the diagnosis was liposarcoma and in 1 neuroblastoma and in 1 neurilemmoma. then followed by radiation theraphy in case I and radiation and chemotheraphy in case II. All three cases showed satisfactory results clinically and radiographically.

  • PDF

Oral Extrusion of Screw after Anterior Cervical Interbody Fusion

  • Lee, Jin-Soo;Kang, Dong-Ho;Hwang, Soo-Hyun;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.259-261
    • /
    • 2008
  • We present a case of delayed oral extrusion of a screw after anterior cervical interbody fusion in a 68-year-old man with osteoporosis. Fifteen months earlier, he had undergone C5 corpectomy and anterior cervical interbody fusion at C4-6 for multiple spinal stenoses. The patient was nearly asymptomatic, except for a foreign body sensation in his throat. We conclude that the use of a mesh graft or other instrument in elderly patients and those with osteoporosis or problematic bone quality should be considered carefully and that if surgery were to be performed, periodic postoperative follow-up evaluations are mandatory.

Spinal Cord Compression as Initial Presentation of Follicular Thyroid Carcinoma

  • Kim, Dae-Ki;Jwa, Cheol-Su;Kim, Kang-Hyun;Kang, Jae-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.4
    • /
    • pp.269-271
    • /
    • 2007
  • Follicular thyroid carcinoma with metastasis rarely manifests as spinal cord compression without any previous symptoms of its malignancy. This report describes a 64-year-old man with follicular thyroid carcinoma who presented initially with left arm motor weakness. Magnetic resonance images demonstrated severe cervical cord compression by a mass with destruction of C4 vertebra. Corpectomy of C4 and anterior interbody fusion was carried out. Histopathological study revealed a metastatic follicular carcinoma of the thyroid. We present our case, especially focused of its possible pathophysiology, with review of pertinent literatures.