Application of Parametric Acoustic Source to Fish Finding (Parametric 음원의 어탐이용에 관한 고찰)

  • Lee, Un-Hui;Jang, Ji-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.4
    • /
    • pp.189-197
    • /
    • 1987
  • As the basic research for the application of a parametric acoustic source to fish finding, the characteristics of beam patterns and parametric gains of the acoustic source were investigated and target strengths of fish, grey mullet, with the acoustic source were measured. The mean primary frequency of the acoustic source was 200KHz and the produced sounds by difference-frequencies were 5KHz, 10KHz, 16KHz and 20KHz. For measurement of target strength in yaw (coronal) plane of fish the to be target was 34cm in length, the pulse duration of the source was 0.3m/sec and the difference frequency was 10KHz in consideration of the length of fish and of parametric gain of the acoustic source. The results obtained are as follow: 1. Beam widths(down 3 dB) of the parametric acoustic source excited at frequencies of 5KHz, 10KHz, 16KHz, and 20KHz were 4.3$^{\circ}$, 2.2$^{\circ}$, 3.0$^{\circ}$ and 2.5$^{\circ}$ respectively. 2. Parametric gains of the parametric acoustic source excited at frequencies of 5KHz, 10KHz, 16KHz and 20KHz were -41 dB, -45 dB, -60 dB and -68 dB respectively. 3. Target strengths of a fish in head and tail aspect using the parametric acoustic source were 5 dB lower than those using 200KHz single frequency sound, but those in side aspect were similar. 4. Target strengths of two or three fish with the parametric acoustic source were 1-3 dB lower than those in head and tail aspect using 200KHz single frequency sound.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

The Measurement of Size of the Pedicle Using 3 Dimensional Reconstruction Image in Idiopathic Scoliosis (특발성 척추측만증 환자에서의 3차원적 재구성을 이용한 척추경의 크기 측정)

  • Heo, Jae-Hee;Ahn, Myun-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.40-50
    • /
    • 2004
  • Background: This study was conducted to analyze the height and width of the pedicle of the upper and lower levels on the concave and the convex sides. In addition, we checked for the appropriate pedicle screw size which could be screwed in without complications. Materials and Methods: Taking a simple AP radiography in a standing position, 99 vertebrae on the major curve with the possibility of 3-D reconstruction were analyzed after checking the CT in a supine position of 22 idiopathic scoliosis. We measured Cobb's angle from a simple radiograph, and measured the size of the isthmus by the Inner Space 3-D Editor after 3-D reconstruction with the Inner Space 3-D program in the DICOM file transformed from CT image. We then analyzed the size of pedicles of the upper and lower levels on the concave and the convex sides by measuring the height and width of the pedicle. Results: All pedicles on the concave side were smaller than those on the convex side. Their size increased as the measurement moved from the upper to lower vertebra, except for the upper thoracic vertebra. When the width of the pedicle through 3-D reconstruction was compared with the narrowest width of the pedicle measured by using CT, the width of the pedicles through 3-D reconstruction was statistically smaller (P<0.01). Most of the pedicles were tear-drop or kidney shaped rather than cylindrical. Conclusion: These results suggest that the use of the coronal plane through 3-D reconstruction would be necessary for an accurate measurement of the size of the pedicle. It is important to pay careful attention to the screw size and the screwing method considering the pedicle shape through 3-D reconstruction.

  • PDF

Current Treatment of Tibial Pilon Fractures (경골 천정(pilon) 골절의 최신 치료)

  • Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

Correlation Analysis between Wheelchair Multi-layer Headrest Foam Properties and Injury Index (Wheelchair Multi-layer headrest foam 특성과 상해지수간 상관관계 분석)

  • Sungwook Cho;Seungmin Ji;Seong S. Cheon
    • Composites Research
    • /
    • v.36 no.4
    • /
    • pp.253-258
    • /
    • 2023
  • Although the development of transportation means has realized the right to mobility for the disabled who have difficulty in moving, it can be said that the improvement of the safety of passengers with disabilities that can occur in a car accident is lower than that of ordinary passenger seats. In particular, in the case of a rear-end collision that can occur suddenly, it is a reality that disabled passengers are vulnerable to head and neck injuries. Therefore, in this study, a multi-layer headrest foam that divides the headrest into three parts in the coronal plane was proposed to improve the head and neck injury index of disabled passengers in the vehicle in the event of a rear-end collision of a wheelchair transport vehicle. A range of stress scale factors was selected to give various compressive characteristics of the foam through low-speed rear-end collision analysis through a simple model, and GA optimization was performed by specifying the range as a parameter. Through the optimization result, the phase relationship between HIC and NIC was analyzed according to the compression characteristics of the layers. HIC responded most sensitively to the compression characteristics of the front layer and NIC responded to the compression characteristics of the mid layer, and the compression characteristics of the rear layer showed the lowest. A normal headrest and an optimized multi-layer headrest were placed in the validation model to analyze the low-speed rear-end collision sled test, and HIC and NIC were derived lower in the multi-layer headrest than in the general headrest. The compression behavior of the multi-layer headrest was also clearly shown, and it was verified that the multi-layer headrest was effective in improving the injury index of the head and neck compared to the general headrest.

Immunocytochemical Localization of Parvalbumin and Calbindin-D 28K in Monkey Dorsal Lateral Geniculate Nucleus (원숭이 외측슬상체배측핵에서 칼슘결합단백 Parvalbumin과 Calbindin-D 28K의 분포)

  • Ko, Seung-Hee;Bae, Choon-Sang;Park, Sung-Sik
    • Applied Microscopy
    • /
    • v.24 no.4
    • /
    • pp.61-77
    • /
    • 1994
  • The calcium-binding proteins (CaBP), parvalbumin (PV) and calbindin-D 28K (calbindin) are particularly abundant and specific in their distribution, and present in different subsets of neurons in many brain regions. Although their physiological roles in the neurons have not been elucidated, they are valuable markers of neuronal subpopulations for anatomical and developmental studies. This study is designed to characterize dorsal lateral geniculate nucleus (dLGN) neurons and axon terminals in terms of differential expression of immunoreactivity (IR) for two well-known CaBPs, PV and calbindin. The experiments were carried out on 6 adult monkeys. Monkeys were perfused under deep Nembutal anesthesia with 2% paraformaldehyde and 0.2% glutaraldehyde in 0.1M phosphate buffer. After removal, the brains were postfixed for 6-8 hr in 2% paraformaldehyde at $4^{\circ}C$ and infiltrated with 30% sucrose at $4^{\circ}C$. Thereafter, they were frozen in dry ice. Serial sections of the thalamus, at $20{\mu}m$, were made in the frontal plane with a sliding microtome. The sections were stained for PV and calbindin with indirect immunocytochemical methods. For electron microscopy, after infiltration with 30% sucrose the blocks of thalamus were serially sectioned at $50{\mu}m$ with a Vibratome in the coronal plane and stained immediately by indirect ABC methods without Triton X-100 in incubation medium. Stained sections were postfixed in 0.2% osmium tetroxide, dehydrated and flat-embedded in Spurr resin. The block was then trimmed to contain only a selected lamina or interlaminar space. The dLGN proper showed strong PV IR in fibers in all laminae and interlaminar zones. Particularly dense staining was noted in layers 1 and 2 that contain many stained fibers from optic tract. Neuronal cell body stained with PV was concentrated only in the laminae. In these laminae staining was moderate in cell bodies of all large and medium-sized neurons, and was strong in cell bodies of some small neurons together with their processes. Calbindin IR was marked in the neuronal cell body and neuropil in the S layers and interlaminar zones whereas moderate in the neuropil throughout the nucleus. Regional difference in distribution of PV and calbindin IR cell is distinct; the former is only in the laminae and the latter in both the S layer and interlaminar space. The CaBP-IR elements were confined to about $10{\mu}m$ in depth of Vibratome section. The IR product for CaBP was mainly associated with synaptic vesicle, pre- and post-synaptic membrane, and outer mitochondrial membrane and along microtubule. PV-IR was noted in various neuronal elements such as neuronal soma, dendrite, RLP, F, PSD and some myelinated or unmyelinated axons, and was not seen in the RSD and glial cells. Only a few neuronal components in dLGN was IR for calbindin and its reaction product was less dense than that of PV, and scattered throughout cytoplasm of soma of some relay neurons, and was also persent in some dendrite, myelinated axons and RLP. The RSD, F, PSD and glial elements were always non-IR for calbindin. Calbindin labelled RLP were presynaptic to unlabeled dendrite or dendritic spine and PSD. Calbindin-labeled dendrite of various sizes were always postsynaptic to unlabeled RSD, RLP or F. From this study it is suggested that dLGN cells of different functional systems and their differential projection to the visual cortex can be distinguished by differential expression of PV and calbindin.

  • PDF

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Review of the Reasons in Cases Requiring Varus/Valgus Constrained Prosthesis in Primary Total Knee Arthroplasty (일차 슬관절 전치환술 시내·외반 구속형 치환물이 필요했던 사례들의 원인 분석)

  • Kong, Dong Yi;Park, Sang Hoon;Choi, Choong Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.253-260
    • /
    • 2021
  • Purpose: The least constrained prosthesis is generally recommended in primary total knee arthroplasty (TKA). Nevertheless, a varus/valgus constrained (VVC) prosthesis should be implanted when a semi-constrained prosthesis is not good for adequate stability, especially in the coronal plane. In domestic situations, however, the VVC prosthesis could not always be prepared for every primary TKA case. Therefore, it is sometimes impractical to use a VVC prosthesis for unsual unstable situations. This study provides information for preparing VVC prostheses in the preoperative planning of primary TKA through an analysis of primary VVC TKA cases. Materials and Methods: This study reviewed 1,797 primary TKAs, performed between May 2003 and February 2016. The reasons for requiring VVC prosthesis and the preoperative conditions in 29 TKAs that underwent primary TKA with a VVC prosthesis were analyzed retrospectively. Results: In primary TKA, 29 cases (1.6%) in 27 patients (6 male and 21 female) used VVC prosthesis. Two patients underwent a VVC prosthesis on both knees. The mean age of the patients was 63.4 years old (34-79 years). The mean flexion contracture was 16.2° (-20°-90°), and the mean angle of great flexion was 111.7° (35°-145°). The situations requiring a VVC prosthesis were severe valgus deformity in 10 knees, knee stiffness requiring extensive soft tissue release in 10 knees, previously injured collateral ligaments in five knees, and distal femoral bone defect due to avascular necrosis in four knees. The mean tibiofemoral angle was 25.7° (21°-43°) in 10 cases with a valgus deformity. The mean flexion contracture was 37.5° (20°-90°), and the mean range of motion was 48.5° (10°-70°) in 10 cases with knee stiffness. Conclusion: The preparation of VVC prosthesis is recommended, even for primary TKA in cases of severe valgus deformity (tibiofemoral angle>20°), stiff knee (the range of motion: less than 70° with more than 20° flexion contracture), and the cases with a previous collateral ligament injury. This information will help in the preparation of adequate TKA prostheses for unusual unstable situations.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.