• Title/Summary/Keyword: Corona Current

Search Result 211, Processing Time 0.03 seconds

Development of an ionic wind dust collector towards coronavirus reduction in subway stations (지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발)

  • Shin, Dongho;Kim, Younghun;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

The Effect of Emotional Effects of ICT Stress and Smart Work on Work Performance (ICT(정보통신기술)스트레스의 정서적영향과 스마트워크가 업무성과에 미치는 영향 연구)

  • Shin, IL-Chul;Seo, Young-Wook
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.309-319
    • /
    • 2022
  • In previous studies, stress in the Information and Communication Technology (ICT) work environment was focused on lowering work performance by negatively affecting the emotions of organizational members. In the current corona pandemic era, as the ratio of organizational members working from home in a smart environment increases, the need for research on the effects of positive and negative stress on work performance is being raised. Accordingly, by applying the Affective Event Theory to the emotional effects of stress on employees' emotional responses, the effects on work performance were analyzed by dividing them into positive and negative emotions. Also, the effect of smart work on work performance was analyzed. This survey was commissioned by a research company and analyzed using Smart PLS 3.0 tool. Therefore, based on the research results, it was suggested that stress does not only negatively affect the emotions of employees, but that the challenge stress that appears in the mind to achieve a goal induces positive emotions in the employees' emotions and helps to improve work performance.

Exploratory Big Data Analysis of Albert Camus's La Peste in Post Corona era (포스트 코로나 시대 알베르 카뮈의 『페스트』에 관한 탐색적 빅데이터 분석)

  • MIN, Jinyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.432-438
    • /
    • 2021
  • This dissertation's object is to confirm the drastic popularity of La Peste of Albert Camus in Korea post-corona society using big data as the mean of inductive research. Analyzing news articles concerning Camus and investigating word frequency of the book La Peste will affirm the implications La Peste has on current Korea society as the outbreak spreads. As an analysis tool, Bigkinds of Korea Press Foundation and Nuagedemots, the French version of Word Cloud were used. For the past 30 years, Albert Camus has been known in Korea as the writer of L'étranger, but after the epidemic, he earned more reputation with La Peste. Compared to L'étranger that rebelled against the world's absurdity with ennui, La peste emphasizes the importance of resistance accompanied by solidarity. La peste conveys hope by depicting disastrous situations of citizens who confront the plague by organizing a health college. The novel delivers a lot of ethical inspiration to humanity in this exceptional circumstance of COVID-19.

Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line (±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가)

  • Woo, Jeong Min;Ju, Mun-No;Shin, Koo Yong;Kwon, Gu Min;Choi, Woo Jung;Lee, Jae Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

A STUDY OF SMALL FLARES ASSOCIATED WITH PLASMA BLOBS OUTFLOWING ALONG POST-CME RAYS

  • Kim, Yoo Jung;Kwon, Ryun-Young;Chae, Jongchul
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • The recent study of Chae et al. (2017) found a one-to-one correspondence between plasma blobs outflowing along a ray formed after a coronal mass ejection (CME) and small X-ray flares. In the present work, we have examined the spatial configuration and the eruption process of the flares that are associated with the blobs by analyzing EUV images and magnetograms taken by the SDO/AIA and HMI. We found that the main flare and the successive small flares took place in a quadrupolar magnetic configuration characterized by predominant magnetic fields of positive polarity, two minor magnetic fragments of negative polarity, and a curved polarity inversion line between them, which suggests that the formation process of the blobs may be similar to that of the parent CME. We also found that the successive flares resulted in a gradual change of the quadrupolar magnetic configuration, and the relevant migration of flaring kernels. The three-dimensional geometry and the property of the current sheet, that is often supposed to be embedded in an observed post-CME ray, seem to keep changing because of mutual feedback between the successive flares and the temporal change of the magnetic field configuration. Our results suggest that the observed post-CME rays may not reflect the characteristics of the current sheet responsible for the impulsive phase of the flare.

Performance Evaluation of Early Streamer Emission Lightning Air Terminal

  • Choi, Sang-Won;Her, Yong
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.18-23
    • /
    • 2006
  • Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

Unity VR 360 Degree Content Implementation (Unity기반의 탐색적 VR 360도 콘텐츠 구현)

  • Shin, Yoo-cheol;Kim, Min-geun;Lee, Hyo-won;Kang, Ha-ram;Park, Cheol-yoo;Lee, Young-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.436-438
    • /
    • 2021
  • This content is implemented for active seniors who actively accept IT digital content as the current metaverse generation arrives. The elderly living in the nursing home can directly explore various parts of the map through the user scenario, so that they can recall their youth or experience various views, such as a place where they spent their lives in the past or a place where they can experience their jobs. In the current situation where the aftermath of Corona is getting stronger, the elderly living in nursing homes can have a positive effect on psychological stability and prevention of depression by using this content.

  • PDF

ESP by using Half-bridge ZCS resonant inverter and Cockroft-Walton circuit (Half-Bridge ZCS resonant inverter 및 Cockroft-Walton회로를 사용한 공기 청정기에 관한 연구)

  • Park, Jong-Woong;Jeong, Jong-Jin;Chung, Hyun-Ju;Joung, Jong-Han;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1951-1953
    • /
    • 2004
  • In this study, we propose a small high voltage power supply which use a half-bridge ZCS resonant and Cockroft-Walton on circuit, for ESP (Electrostatic Precipitator). This power supply transfers energy from ZCS resonant inverter to step-up transformer and the transformer secondary is applied to the Cockroft-Walton circuit for generating high voltage as discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50 % in this ESP.

  • PDF

A study on the characteristic of corona electrification current of polymer materials contained fluoric component (불소계 고분자 재료의 코로나 대전 전류 특성에 관한 연구)

  • 이덕출;박광현
    • Electrical & Electronic Materials
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 1991
  • 본 논문은 기중 코로나 방전에 의하여 생성된 캐리어를 Teflon-FEP 표면에 균일하게 공급하였을 때 Teflon-FEP를 통하여 흐르는 코로나 대전전류 특성에 대하여 연구하였다. 불소를 함유한 Teflon-FEP는 코로나 대전전류에 극성효과가 현저히 나타난다. 즉 정극성 캐리어는 벌크내를 쉽게 이동하나 부극성 캐리어는 안정하게 trap되어 벌크내를 이동하기 어렵기 때문에 부극성 코로나 대전전류 보다 정극성 코로나 대전전류가 크게 흐름을 알았다. 이와같이 극성효과가 나타나는 것은 Teflon-FEP가 전자 친화력이 있는 불소를 함유하고 있기 때문임을 제시하였다. 이러한 사실은 Polysulfone(PSF), High density Polyethylene(HDPE) 및 Polythylene Terephtarate(PET)의 코로나 대전전류 특성으로부터 확인할 수 있었다.

  • PDF

The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings (회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF