• Title/Summary/Keyword: Corona Current

Search Result 211, Processing Time 0.028 seconds

Flashover Characteristics of the Horizontal Air Gaps Caused by Combustion Flames (연소화염에 의한 수평배치 공기갭의 섬락전압 특성)

  • 김인식;김이국;김충년;지승욱;이상우;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • In this paper, characteristics of the ac and dc flashover voltage in the horizontal air gap of a needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrode. In order to examine the flashover phenomena and the corona inception voltages caused by flame we measured the voltage and current waveforms when the corona and the flashover was occurred. We also observed, as increasing the applied voltages, the deflection or fluctuation phenomena in the shape of flames caused by the corona wind and the coulomb's force. As the results of an experimental investigation, we found that the reduction of flashover voltages, in comparison with the no-flame case, are 62.7[%] for k=1.0, 34.2[%] for h=5[cm], 27.3[%] for h=7[cm] and 21.4[%] for h=9[cm] when ac voltage is applied.

Comparative Performance Evaluation of Lightning Air Terminals by the HV Laboratory Test (고전압 모의시험을 통한 피뢰침의 성능 비교평가)

  • Lee, Jae-Bok;Myeong, Seong-Ho;Jo, Yeon-Gyu;Kim, Jeom-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.627-632
    • /
    • 2001
  • There are claims that ESE(Early streamer emission) Air terminals offer a vastly increased zone of protection over that of traditional lightning rods by causing the emission of an upward streamer/leader that will propagate towards the tip of downward leader at an early stage in the attachment process than would occur for a simple rod in the same geometrical configurations. This paper shows the results of comparing test a particular type of ESE air terminals with a simple rod conducted in the KEH HV laboratory, which are lightning impulse voltage test, flashover direction test and corona emission current measurement. The results from this test show a completely random scattering of flashovers to the conventional and ESE air terminals under identical electrics] and geometrical conditions, and thus shows no advantage of one terminal over the other.

  • PDF

Corona Blue and Leisure Activities : Focusing on Korean Case (코로나 블루와 여가 활동 : 한국 사례를 중심으로)

  • Sa, Hye Ji;Lee, Won Sang;Lee, Bong Gyou
    • Journal of Internet Computing and Services
    • /
    • v.22 no.2
    • /
    • pp.109-121
    • /
    • 2021
  • As the global COVID-19 pandemic is prolonged, the Corona Blue phenomenon, combined with COVID-19 and blue, is intensifying. The purpose of this study is to analyze the current trend of Corona Blue in consideration of the possibility of increasing mental illness and the need for countermeasures, especially after COVID-19. This study tried to find out the relationship between stress and leisure activities before and after COVID-19 by using Corona Blue news article analysis through the topic modeling method, and questionnaire find out the help of stress and leisure activities. This study was compared and analyzed using two research methods. First, a total of 363 news articles were analyzed through topic modeling based on newspaper articles from January 2020, when COVID- 19 was upgraded to the "border" stage, until September, where the social distancing stage was strengthened to stage 2.5 in Korea. As a result of the study, a total of 28 topics were extracted, and similar topics were grouped into 7 groups: mental-demic, generational spread, causes of depression acceleration, increased fatigue, attitude to coping with long-term wars, changes in consumption, and efforts to overcome depression. Second, the SPSS statistical program was used to analyze the level of stress change according to leisure activities before/after COVID-19 and the main help according to leisure activities. As a result of the study, it was confirmed that the average difference in stress reduction according to participation in leisure activities before COVID-19 was larger than after COVID-19. Also, leisure activities were found to be effective in stress relief even after COVID-19. In addition, if the main help from leisure activities before COVID-19 was the meaning of relaxation and recharging through physical and social activities. After COVID-19, psychological roles such as mood swings through nature, outdoor activities, or intellectual activities were found to play a large part. As such, in this study, it was confirmed that understanding the current status of Corona Blue and coping with leisure in extreme stress situations has a positive effect. It is expected that this research can serve as a basis for preparing realistic and desirable leisure policies and countermeasures to overcome Corona Blue.

The Charge decay characteristics of Polymer surface by Corona discharge (코로나 하전한 고분자의 표면전하감쇄)

  • Lee, B.S.;Kim, Y.B.;Park, J.K.;Kim, J.S.;Lee, J.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1156-1158
    • /
    • 1995
  • Charge decay, thermally stimulated current(TSC), charging and discharging currents(I) are measured for negatively corona-charged polymers. In this study, we will make an experiment in charge decay on polymer surface, TSC, polarity effect and the others in order to analysis it's mechanism. Especially polyvinylidene fluoride(PVDF) film is the best functional material which has been so far. Therefore, It's worthy of notice to investigate it's characteristic. And then some other functional polymers will be focused on. An experimental result was missed out for the shortage of setting. So, this thesis will be explained on the theory and direction of reseach hereafter.

  • PDF

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

Calculation on the Ion Flow Field under HVDC Transmission Lines Considering Wind Effects

  • Wu, Jing;Gao, Sheng;Liu, Yuxiao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2077-2082
    • /
    • 2015
  • Based on Deutsch assumption, a calculation method on the electric field over the ground surface under HVDC transmission lines in the wind is proposed. Analyzing the wind effects on the electric field and the space charge density the existing method based on Deutsch assumption is improved through adding the wind speed to the ion flow field equations. The programming details are illustrated. The calculation results at zero wind speed are compared with available data to validate the code program. Then the ionized fields which resulted from corona of ±800kV HVDC lines are analyzed. Both the electric field and the current density on the ground level are computed under different wind direction and speed. The computation results are in good agreement with measurements. The presented method and code program can be used to rapidly predict and evaluate the wind effects in HVDC transmission engineering.

The Study on Potential Characteristics and Corona Discharge of Composite Insulating Material (복합절연재료 FRP의 코로나 대전파 전위감쇄특성에 관한 연구)

  • 이백수;신태현;김진식;강대하;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.365-368
    • /
    • 1995
  • Charge decay, thermally stimulated current (TSC), charging and discharging currents(I) are measured for corona-charged composite insulating materials. In this study, We will make an experiment in charge decay on composite material surface, TSC, polarity effect and the others in order to analysis its mechanism. Especially, Fiber glass Reinforced Plastics(FRP) is the best composite material which has been so far. Therefore, Its worthy of notice to investigate its characteristic. And then some other materials will be focused on. This experiment measured characteristic of charge decay, dependence of discharging-time and other electrostatic characteristics on FRP.

  • PDF

Analysis on the Degradation of Insulators using Corona Camera (코로나 카메라를 이용한 불량애자 검출사례 분석)

  • Kim, H.S.;Kim, P.H.;You, Y.K.;Koo, K.W.;Kim, H.J.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

NUMERICAL MODELING OF WIRE ELECTROHYDRODYNAMIC FLOW IN A WIRE-PLATE ESP

  • Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.164-171
    • /
    • 2006
  • Numerical modeling of the flow velocity fields for the near corona wire electrohydrodynamic (EHD) flow was conducted. The steady, two-dimensional momentum equations have been computed for a wire-plate type electrostatic precipitator (ESP). The equations were solved in the conservative finite-difference form on a fine uniform rectilinear grid of sufficient resolution to accurately capture the momentum boundary layers. The numerical procedure for the differential equations was used by SIMPLEST algorithm. The Phoenics (Version 3.5.1) CFD code, coupled with Poisson's electric field, ion transport equations and the momentum equation with electric body force were used for the numerical simulation and the Chen-Kim ${\kappa}-{\varepsilon}$ turbulent model numerical results that an EHD secondary flow was clearly visible in the downstream regions of the corona wire despite the low Reynolds number for the electrode ($Re_{cw}=12.4$). Secondary flow vortices caused by the EHD increases with increasing discharge current or EHD number, hence pressure drop of ESP increases.