1 |
Z. Y. Sun, L. S. Zeng and J. Y. Lu, “Guide for HVDC overhead transmission lines, DL/T436-2005,” Power industry standard of the People’s Republic of China Tech, Nov. 1, 2005.
|
2 |
P. S. Maruvada and W. Janischewskyj, “Analysis of corona losses on DC transmission lines: I - unipolar lines,” IEEE Trans. Power Apparatus and Systems, vol. 88, pp.718-731, 1969.
|
3 |
P. S. Maruvada and W. Janischewskyj, “Analysis of corona losses on DC transmission lines: II - bipolar lines,” IEEE Trans. Power Apparatus and Systems, vol. 88, pp.1476-1491, 1969.
|
4 |
Y. Yang, J. Y. Lu and Y. Z. Lei, “A calculation method for the electric field under double-circuit HVDC transmission lines,” IEEE Trans. Power Delivery, vol. 23, pp.1736-1742, 2008.
DOI
|
5 |
A. Shemshadi, K. Niayesh and A. Akbari, “Influence of the airflow speed along transmission lines on the DC corona discharge loss, using finite element approach,” Physics of Plasmas, vol. 19, pp. 073506-073515, 2012.
DOI
|
6 |
T. Zhao, S. A. Sebo and D. G. Kasten, “Calculation of single phase AC and monopolar DC hybrid corona effects,” IEEE Trans. Power Delivery, vol. 11, pp. 1454-1463, 1996.
DOI
|
7 |
W. Janischewskyj and G. Gela, “Finite Element Solution for Electric Fields of Coronating DC Transmission Lines,” IEEE Trans. Power Apparatus and Systems, vol. 98, pp. 1000-1012, 1979.
|
8 |
T. Takuma, I. Tsutomu and K. Tadashi, “Calculation of ion flow fields of HVDC transmission lines by the finite element method,” IEEE Trans. Power Apparatus and Systems, vol. 100, pp. 4802-4810, 1981.
|
9 |
H. Yin, B. Zhang, J. He and R. Zeng, “Time-domain finite volume method for ion-flow field analysis of bipolar high-voltage direct current transmission lines,” IET Generation, Transmission & Distribution, vol. 6, pp.785-791, 2012.
DOI
|
10 |
M. Brahami, A. Gourbi and A. Tilmatine, “Numerical analysis of the induced corona vibrations on high-voltage transmission lines affected by rainfall,” IET Generation, IEEE Trans. Power Delivery, vol. 26, pp.617-624, 2011.
DOI
|
11 |
Y. S. Zhao and W. L. Zhang, “Effects of fog on ion flow field under HVDC transmission lines,” Proceedings of the CSEE, vol. 33, pp. 194-199, 2013.
|
12 |
P. S. Maruvada, “Electrostatic field of a system of parallel cylindrical conductors,” IEEE Trans. Power Apparatus and Systems, vol. 88, pp. 1069-1079, 1969.
|
13 |
M. A. Salam and D. Shamloul, “Computation of ionflow fields of accoronating wires by charge simulation techniques,” IEEE Trans. Electrical Insulation, vol. 27, pp. 352-361, 1992.
DOI
|
14 |
M. P. Sarma, “Corona performance of high-voltage transmission lines.” New York: Research Studies Press, pp. 82-83, 2000.
|
15 |
Y. Yang, J. Y. Lu and Y. Z. Lei, “A calculation method for the hybrid electric field under UHVAC and UHVDC transmission lines in the same corridor,” IEEE Trans. Power Delivery, vol. 25, pp.1146-1153, 2010.
DOI
|
16 |
General Electric Company, “EL-2419 HVDC transmission line research,” EPRI, 1982.
|
17 |
Y. Yang, “Analysis and calculation of the electric field under Ac and DC transmission lines in the same transmission corridor,” Beihang University, Beijing, China, 2008.
|
18 |
P. S. Maruvada, “Electric field and ion current environment of HVDC Transmission lines: comparison of calculations and measurements,” IEEE Trans. Power Delivery, vol. 27, pp. 401-410, 2012.
DOI
|