• 제목/요약/키워드: Corona

검색결과 1,314건 처리시간 0.033초

MEASUREMENT OF COASTAL EROSION ON THE EAST SEA USING CORONA SATELLITE IMAGERY

  • Park, Hee-Dae;Kim, Jong-Hong;Heo, Joon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.760-763
    • /
    • 2006
  • In this paper, a small portion of coastline on the EAST SEA was studied using CORONA panoramic satellite photo and 1:5000 Korean National Topographic Map. The project site near Kangneung city was 3 Km shoreline on the Kangmoon Beach and the SongJeong Beach, which have suffered from severe erosion. The first and the most important step was to rectify a CORONA image over the project site. A rigid mathematical model and a heuristic polynomial transformation were used for the purpose. The rectified image was overlaid with 1:5000 Korean National Topographic Map produced by aerial mapping. Among numerous methods for shoreline erosion measurement, area-based approach was chosen and used for the computation for annual shoreline recession. The final result of the analysis was that the average recession in the period of 1963-1998 was 33.6m and the annual rate was 0.96m.

  • PDF

코로나 방전-EGR 조합시스템에 의한 디젤기관의 배기 가스 특성 (The Characteristics of Exhaust Gas in Diesel Engine by Corona Discharge-EGR System)

  • 하현진;박재윤;정장근;김선호;고희석;배명환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1115-1118
    • /
    • 2003
  • A great part of flint fuel is Hydrogen and carbon's combination. they should be generated steam and carbon gas when combine with oxygen for perfect combustion in the inside of engine, but the pollutive material especially NOx and Soot are exhausted, even though fuel is combine perfectly. In this paper the characteristics of exhaust material from diesel engine is investigated for the corona discharge-EGR hybrid plasma reactor, which combined corona discharge with EGR system. NOx is decreased in all load and applied voltage to plasma reactor. However Soot is increased as increasing EGR rate and it is decreased as increasing applied voltage.

  • PDF

Improvement of Corona Temperature and Velocity Determination Method Using a Coronagraph Filter System

  • Cho, Kyuhyoun;Chae, Jongchul;Lim, Eun-Kyung
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.85.3-86
    • /
    • 2017
  • We have developed a methodology to determine the coronal electron temperature and solar wind speed using a four filter coronagraph system. The method developed so far have been applied to total eclipse observation and have yielded plausible results. The current methodology starts from the assumption that 1) coronal free electrons are isothermal and 2) coronal free electrons have spherically symmetric distrubution. However, the actual solar corona differs significantly from the two assumptions above. The coronal electron density is not spherically symmetric due to streamers, plumes, and coronal loops, and the electron temperature is also expected to increase rapidly with distance from the sun. We will discuss how to determine the temperature and wind speed of the corona in the case of corona with thermal structures and non-spherical symmetric electron density.

  • PDF

소용량 EHD 발전에 관한 실험적 연구 (An Experimental Study on the Small Capacity EHD Power Generation)

  • 전춘생;이재복;임응춘
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.58-68
    • /
    • 1989
  • This paper describes an experimental study that was performed to determine the limiting factors on the power output in the closed cycle Electro-Hydro-Dynamic generator of small capacity. A corona discharge for producing unipolar charged particles used as the charging method. The experiment demonstrated that the corona method of charging was an efficient and effective means of producing unipolar charged particles. Four factors having an effect on the power output characteristics of EHD generator are discussed and examined experimentally, using methyl alcohol and kerosene as working fluides; a. The conversion length between attractor and collector. b. The corona current of Emitter. c. The flow velocity of working fluids. d. Load resistance. This results are as follows; 1) There in a critical value in conversion length for its maximum power output. 2) Power output increases almost linearly with corona current and flow velocity. 3) There is the critical value of load resistance producing a maximum power output. 4) Kerosene is known better working fluid than Methyl alcohol in this EHD generator.

  • PDF

Simulation of the Corona Charging Process in Polypropylene Electret for Sensor Material

  • Park, Geon-Ho;Park, Young-Chull;Yang, Jung-Yoon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.68-72
    • /
    • 2000
  • In order to estimate spatial charging process in the corona charging which has been used to make polymer electret, the electrical properties of polypropylene film were obtained from Thermally Stimulated Current (TSC) measurements after corona charging between knife electrode and cylinder electrode with the voltages of -5, -6, -7 and -8[kV], respectively. And then the electrostatic contour and the electric field vector were also simulated by using Finite Element Method (FEM). The edge effect around edge of knife electrode affected the electrostatic contour on surface of specimen and the electric field concentration inside specimen. The uneven charging state in the electret due to the mistake on design could be calculated and so the optimal design of corona charging device which is appropriate to various materials is come to be practicable.

  • PDF

Transesterification of Vegetable Oils in Pulsed-Corona Plasma Discharge Process

  • Hyun, Young-Jin;Mok, Young-Sun;Jang, Doo-Il
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2012
  • The biodiesel production characteristics in a pulsed-corona plasma reactor has been investigated through parametric tests. Transesterification of rapeseed oil together with camelina oil was done with the change of such variables as voltage of power, molar ratio, KOH catalyst and temperature. The energetic electrons emitted from pulsed-corona plasma has contributed to the enhancement of yield on rapeseed oil in short time (15 min). The higher yield on camelina oil was observed in 5 min. The optimal parameters were shown as the voltage of 23 kV, the molar ratio of 5/1, the content of KOH catalyst of 0.6 wt% and the temperature of $28^{\circ}C$ under the rotating rate of spark gap of 900 rpm.

코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구 (A Study on the Charging and discharging current of corona charged Teflon-FEP film)

  • 정기석;이승우;박광현;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1988년도 춘계학술대회 논문집
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

전극길이 및 펄스반복율에 대한 부하임피던스 특성변화 및 EMTP 해석에 관한 연구 (A Study on the Characteristics of Corona Critical Voltage and EMTP Simulatuon on Increasing Load Impedance and Pulse Repetition)

  • 정종한;송우정;전진안;이유수;김휘영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1850-1852
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable Pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

변압기의 고장검출을 위한 유중 코로나 특성 연구 (Transformer diagnosis using characteristics of corona in Oil)

  • 권태원;곽희로;김재철;김응상;박민규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

펄스 코로나 방전 공정에서 탈질, 탈황 효율의 실험적 분석 (Experimental Analysis on the Desulfurizarion and Denitrification Efficiencies in Pulsed Corona Discharge Process)

  • 김성민;김교선
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.181-186
    • /
    • 2003
  • In this study, we analyzed $NO_x$ and $SO_x$ removal efficiencies by a pulsed corona discharge process and investigated the effect of several process variables. The removal efficiencies of NO and $SO_2$ were measured changing the process variables of initial concentrations of NO, $H_2O$, and $NH_3$, $SO_2$, applied voltage, pulse frequency and residence time. As the applied voltage or the frequency of applied voltage or the residence time increases, the NO and $SO_2$ removal efficiencies increase. The NO and $SO_2$ removal efficiencies also increase by the addition of $O_2$ or $H_2O$, or by using the large diameter of the discharge electrode. The experimental results can be used as a basis to design the pulsed corona discharge process to remove $NO_x$, $SO_x$ and VOCs.

  • PDF