• 제목/요약/키워드: Corona

검색결과 1,314건 처리시간 0.031초

Alkyl Group Dissociation During Corona Excitation of Alkylbenzenes

  • Yoon, Young-Wook;Lee, Sang-Kuk
    • 대한화학회지
    • /
    • 제55권5호
    • /
    • pp.741-745
    • /
    • 2011
  • Well-resolved vibronic emission spectra were recorded in the visible region from the corona discharge of precursor alkylbenzenes in a technique of corona excited supersonic expansion using a pinhole-type glass nozzle. From the observed spectra, we found the evidence of the presence of benzyl-type radicals generated by dissociation of C-C or C-H bonds of alkyl group. After identification of benzyl-type radicals formed in the corona discharge, we suggest that energy densities in alkyl chain play a crucial role in determining the bond dissociation during corona excitation.

Corona pulse 검출에 의한 전력기기절연진단에 대한-고찰 (A study on the insulation detection for electrical machnes by corona pulse technique)

  • 성영권;정성계;김왕곤
    • 전기의세계
    • /
    • 제16권5호
    • /
    • pp.15-18
    • /
    • 1967
  • This paper shows the analysis for mechanisms of corona pulse caused by dielectric breakdown, and for the results of observed values on an actual machines with the this corona pulse technique. Although the above results are not directly related with the generation, numbers or wave of the corona pulse, it may possibly be chanced a judgement of dielectric breakdown and one of better synthetic judgement methods for actual electrical machines.

  • PDF

765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger

  • Intra, Panich;Yawootti, Artit;Vinitketkumnuen, Usanee;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.556-562
    • /
    • 2011
  • In the present study, a simple corona-wire charger for unipolar diffusion charging of aerosol particles is designed, constructed, and characterized. Experimental characterizations of the electrostatic discharge in terms of current-voltage relationships of positive and negative coronas of the corona-wire charger are also presented and discussed. The charging current and ion concentration in the charging zone increased monotonically with corona voltage. The negative corona showed higher current than the positive corona. At the same corona voltages, the current in the discharge zone is about 600 times larger than the charging current. The ion number concentrations ranged within approximately $5.0{\times}10^{10}$ to $1.24{\times}10^{16}$ and $4.5{\times}10^{12}$ to $2{\times}10^{16}$ ions/$m^3$ in the discharge and charging zones, respectively. A numerical model is used to predict the behavior of the electric potential lines. Numerical results of ion penetration through the inner electrode are in good agreement with the experimental results.

초고압 직류 가공송전 후보 도체방식의 이온류 환경특성 코로나 케이지 모의시험 (Corona Cage Simulation on Environmental Characteristics Caused by the Ion flow of Candidated Conductor Bundles for HVDC Overhead Transmission)

  • 주윤노;양광호;이동일;신구용
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1791-1795
    • /
    • 2007
  • Small ions generated at conductor corona sources remain in the atmosphere until they recombine with ions of opposite polarity, attach to aerosols, or make contact with an object. Ion current density is major factor to design conductor configuration of DC overhead transmission line. Several techniques have been used to measure the ion current of HVDC overhead transmission line. In this study, the ion current density was measured by a plate electrode made of a metal flat board at DC corona cage. The sensitivity of the plate electrode is $0.156uA/m^2/V$. To obtain an useful database on corona discharge, it is necessary to do corona test on several kinds of conductor bundles. Therefore, a number of experiments were conducted on several kinds of conductor bundles. To reliably analyze ion effects, corona cage test data were obtained over a long period of time under various weather conditions and expressed as a statistical distribution. Ion current density distribution in foul weather shows a significant increase in levels over the corresponding fair weather. Based on this results, we evaluated the environmental characteristic caused by ion flow of three candidated conductor bundles.

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • 제6권2호
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

코로나방전에 의한 $NO_2$ 전환특성 및 soot 산화에 관한 연구 (An experimental study on $NO-NO_2$ conversion characteristics and oxidation of soot by corona discharge)

  • 박용성;전광민;박광서;이종현;조성우
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.179-184
    • /
    • 2001
  • The characteristics of $NO-NO_2$ conversion and soot oxidation by corona discharge are investigated experimentally. The discharge current decreases with the increase of oxygen concentration and it increases more sharply for anode corona than for cathode corona as discharge voltage increases after corona onset voltage. $NO-NO_2$ conversion increases with the energy density of corona discharge and the addition of $O_2$ in a base $N_2$ gas. Soot oxidation occurs at approximately $480^{\circ}C$ in a mixture of 21% $O_2$, base $N_2$ gas, and enhances as temperature increases. The initiation temperature of soot oxidation advances greatly to about $280^{\circ}C$ with the addition of 300ppm $NO_2$, which is generated from the conversion of NO to $NO_2$ by corona discharge. CO is generated at higher temperature by about $50{\sim}100^{\circ}C$ than $CO_2$ in the process of soot oxidation.

  • PDF

실시간 미세입자 측정을 위한 다이오드형 코로나 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Diode Type Corona Charger for Real-Time Measurement of the Submicron Aerosol)

  • 조명훈;지준호;박동호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1066-1074
    • /
    • 2004
  • With a diode corona charger, which is a component of ELPI(Electrical Low Pressure Impactor), aerosol particles are charged to make electrical detection possible before they are collected by the impactor. We designed and evaluated two cylindrical corona chargers, each of which had a central corona needle electrode. For the performance evaluation of each corona charger the polydisperse dioctyl sebacate(DOS) particles, with diameters of 0.1∼0.8 $\mu$m and NaCl particles, smaller than 0.1$\mu$m, were used. The particles were then led through an electrostatic classifier (TSI model 3081) to classify monodisperse aerosol with minimal size deviation. After evaluating the wall loss of the particles in the corona charger, we measured the product of penetration and number of charges, Pㆍn, to evaluate the corona charger efficiency at high positive voltages of 4, 5, 6 kV.

강유전체 충진 선대선 방전갭의 코로나 방전 및 오존 발생특성 (Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Gap with a Ferroelectric Pellet Bed)

  • 신정민;배창환;안창진;이종훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1873-1875
    • /
    • 2003
  • Surface corona discharge characteristics of a ac corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charged stored on the surfaces of the ferroelectric pellets by a at corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between wire electrodes. As a result, in the case of the corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be generated efficiently. It is also found that, the ferroelectric pellet barrier discharge reactor had better discharge characteristics for plasma generation than the wire-to-wire discharge reactor without pellets.

  • PDF

CORONA 영상을 이용한 한반도 지역 모자이크 영상 제작 (Creating Mosaic Image of the Korean Peninsula from CORONA Imagery)

  • 송영선
    • 대한공간정보학회지
    • /
    • 제13권4호
    • /
    • pp.67-73
    • /
    • 2005
  • 우리나라는 1960년대부터 급속한 도시화가 이루어졌으나, 현재까지 활용되어온 위성영상들은 1970년대 이후에 얻어진 영상들이기 때문에 과거 1960년대 한반도 지역의 지형정보를 제공해 줄 수 있는 자료가 거의 없다. 최근에 일반인에게 공개된 CORONA 영상은 과거 1960년대의 한반도 지형정보를 고해상도 및 광역적 범위로 제공할 수 있는 영상으로써, 도시, 산림, 환경 등 여러 분야의 변화탐지 자료로 활용성이 크다. 본 연구에서는 1960년대의 CORONA 영상을 이용한 과거 한반도 지역 모자이크 영상의 제작을 목적으로 하였으며, 이를 위하여 기하보정 방법으로 1차, 2차, 3차 다항식과 변형된 공선조건식에 대한 정확도를 평가하였다. 정확도를 평가한 결과 엄밀식의 정확도가 가장 높았으나 지상 기준점 취득의 문제로 인해 20개의 기준점을 사용한 2차 다항식으로 기하보정을 수행한 후 한반도 모자이크 영상을 제작하는 것이 효율적이라는 결론을 얻었다. 이를 바탕으로 1960년대 한반도 지역을 모두 포함하는 CORONA 모자이크 영상을 생성하였으며, 생성된 모자이크 영상은 도시계획이나 변화탐지와 같은 다양한 분야에 활용이 가능할 것으로 예상된다.

  • PDF