• Title/Summary/Keyword: Core-needle biopsy

Search Result 49, Processing Time 0.023 seconds

Comparison of Core Needle Biopsy and Repeat Fine-Needle Aspiration in Avoiding Diagnostic Surgery for Thyroid Nodules Initially Diagnosed as Atypia/Follicular Lesion of Undetermined Significance

  • Leehi Joo;Dong Gyu Na;Ji-hoon Kim;Hyobin Seo
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.280-288
    • /
    • 2022
  • Objective: To compare core needle biopsy (CNB) and repeat fine-needle aspiration (rFNA) to reduce the rate of diagnostic surgery and prevent unnecessary surgery in nodules initially diagnosed as atypia/follicular lesions of undetermined significance (AUS/FLUS). Materials and Methods: This study included 231 consecutive patients (150 female and 81 male; mean age ± standard deviation, 51.9 ± 11.7 years) with 235 thyroid nodules (≥ 1 cm) initially diagnosed as AUS/FLUS, who later underwent both rFNA and CNB. The nodules that required diagnostic surgery after the biopsy were defined using three different scenarios according to the rFNA and CNB results: criterion 1, surgery for low-risk indeterminate (categories I and III); criterion 2, surgery for high-risk indeterminate (categories IV and V); and criterion 3, surgery for all indeterminate nodules (categories I, III, IV, and V). We compared the expected rates of diagnostic surgery between CNB and rFNA in all 235 nodules using the three surgical criteria. In addition, the expected rates of unnecessary surgery (i.e., surgery for benign pathology) were compared in a subgroup of 182 nodules with available final diagnoses. Results: CNB showed significantly lower rates of nondiagnostic, AUS/FLUS, and suspicious for malignancy diagnoses (p ≤ 0.016) and higher rates of follicular neoplasm or suspicious for a follicular neoplasm (p < 0.001) and malignant diagnoses (p = 0.031). CNB showed a significantly lower expected rate of diagnostic surgery than rFNA for criterion 1 (29.8% vs. 48.1%, p < 0.001) and criterion 3 (46.4% vs. 55.3%, p = 0.029), and a significantly higher rate for criterion 2 (16.6% vs. 7.2%, p = 0.001). CNB showed a significantly lower expected rate of unnecessary surgery than rFNA for criterion 1 (18.7% vs. 29.7%, p = 0.024). Conclusion: CNB was superior to rFNA in reducing the rates of potential diagnostic surgery and unnecessary surgery for nodules initially diagnosed as AUS/FLUS in a scenario where nodules with low-risk indeterminate results (categories I and III) would undergo surgery.

Guidelines for Transrectal Ultrasonography-Guided Prostate Biopsy: Korean Society of Urogenital Radiology Consensus Statement for Patient Preparation, Standard Technique, and Biopsy-Related Pain Management

  • Myoung Seok Lee;Min Hoan Moon;Chan Kyo Kim;Sung Yoon Park;Moon Hyung Choi;Sung Il Jung
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.422-430
    • /
    • 2020
  • The Korean Society of Urogenital Radiology (KSUR) aimed to present a consensus statement for patient preparation, standard technique, and pain management in relation to transrectal ultrasound-guided prostate biopsy (TRUS-Bx) to reduce the variability in TRUS-Bx methodologies and suggest a nationwide guideline. The KSUR guideline development subcommittee constructed questionnaires assessing prebiopsy anticoagulation, the cleansing enema, antimicrobial prophylaxis, local anesthesia methods such as periprostatic neurovascular bundle block (PNB) or intrarectal lidocaine gel application (IRLA), opioid usage, and the number of biopsy cores and length and diameter of the biopsy needle. The survey was conducted using an Internet-based platform, and responses were solicited from the 90 members registered on the KSUR mailing list as of 2018. A comprehensive search of relevant literature from Medline database was conducted. The strength of each recommendation was graded on the basis of the level of evidence. Among the 90 registered members, 29 doctors (32.2%) responded to this online survey. Most KSUR members stopped anticoagulants (100%) and antiplatelets (76%) one week before the procedure. All respondents performed a cleansing enema before TRUS-Bx. Approximately 86% of respondents administered prophylactic antibiotics before TRUS-Bx. The most frequently used antibiotics were third-generation cephalosporins. PNB was the most widely used pain control method, followed by a combination of PNB plus IRLA. Opioids were rarely used (6.8%), and they were used only as an adjunctive pain management approach during TRUS-Bx. The KSUR members mainly chose the 12-core biopsy method (89.7%) and 18G 16-mm or 22-mm (96.5%) needles. The KSUR recommends the 12-core biopsy scheme with PNB with or without IRLA as the standard protocol for TRUS-Bx. Anticoagulants and antiplatelet agents should be discontinued at least 5 days prior to the procedure, and antibiotic prophylaxis is highly recommended to prevent infectious complications. Glycerin cleansing enemas and administration of opioid analogues before the procedure could be helpful in some situations. The choice of biopsy needle is dependent on the practitioners' situation and preferences.

Diagnostic Aspects of Fine Needle Aspiration for Lung Lesions: Series of 245 Cases

  • Kravtsov, Vladimir;Sukmanov, Inna;Yaffe, Dani;Shitrit, David;Gottfried, Maya;Cioca, Andreea;Kidron, Debora
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9865-9869
    • /
    • 2014
  • Background: Transthoracic fine needle aspiration (FNA) is one of several methods for establishing tissue diagnosis of lung lesions. Other tissue or cell sources for diagnosis include sputum, endobronchial biopsy, washing and brushing, endobronchial FNA, transthoracic core needle biopsy, biopsy from thoracoscopy or thoracotomy. The purpose of this study was to compare the sensitivity and specificity of FNA and other diagnostic tests in diagnosing lung lesions. Materials and Methods: The population included all patients undergoing FNA for lung lesions at Meir Medical Center from 2006 through 2010. Information regarding additional tissue tests was derived from the electronic archives of the Department of Pathology, patient records and files from the Department of Oncology. Sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values were calculated for each test. Results: FNA was carried out in 245 patients. Malignant tumors were diagnosed in 190 cases (78%). They included adenocarcinoma (43%), squamous cell carcinoma (15%), non-small cell carcinoma, not otherwise specified (19%), neurondocrine tumors (7%), metastases (9%) and lymphoma (3%). The specificity of FNA for lung neoplasms was 100%; sensitivity and diagnostic accuracy were 87%. Conclusions: FNA is the most sensitive procedure for establishing tissue diagnoses of lung cancer. Combination with core needle biopsy increases the sensitivity. Factors related to the lesion (nature, degenerative changes, location) and to performance of all stages of test affect the ability to establish a diagnosis.

Percutaneous Ultrasound-Guided Fine-Needle Aspiration Cytology and Core-Needle Biopsy for Laryngeal and Hypopharyngeal Masses

  • Dongbin Ahn;Gil Joon Lee;Jin Ho Sohn;Jeong Eun Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.596-603
    • /
    • 2021
  • Objective: To evaluate the feasibility and diagnostic performance of ultrasound (US)-guided fine-needle aspiration cytology and core-needle biopsy (US-FNAC/CNB) for the diagnosis of laryngo-hypopharyngeal masses. Materials and Methods: This was a single-center prospective case series. From January 2018 to June 2019, we initially enrolled 40 patients with highly suspicious laryngo-hypopharyngeal masses on laryngoscopic examinations. Of these, 28 patients with the mass involving or abutting the pre-epiglottic, paraglottic, pyriform sinus, and/or subglottic regions were finally included. These patients underwent US examinations with/without subsequent US-FNAC/CNB under local anesthesia for evaluation of the laryngo-hypopharyngeal mass. Results: Of the 28 patients who underwent US examinations, a laryngo-hypopharyngeal mass was identified in 26 patients (92.9%). US-FNAC/CNB was performed successfully in 25 of these patients (96.2%), while the procedure failed to target the mass in 1 patient (3.8%). The performance of US caused minor subclinical hematoma in 2 patients (7.7%), but no major complications occurred. US-FNAC/CNB yielded conclusive results in 24 (96.0%) out of the 25 patients with a successful procedure, including 23 patients with squamous cell carcinoma (SCC) and 1 patient with a benign mass. In one patient with atypical cells in US-FNAC, additional direct laryngoscopic biopsy (DLB) was required to confirm SCC. Among the 26 patients who received US-FNAC/CNB, the time from first visit to pathological diagnosis was 7.8 days. For 24 patients finally diagnosed with SCC, the time from first visit to the initiation of treatment was 25.2 days. The mean costs associated with US-FNAC/CNB was $272 under the Korean National Health Insurance Service System. Conclusion: US-FNAC/CNB for a laryngo-hypopharyngeal mass is technically feasible in selected patients, providing good diagnostic performance. This technique could be used as a first-line diagnostic modality by adopting appropriate indications to avoid general anesthesia and DLB-related complications.

Comparison between Radiological and Invasive Diagnostic Modalities in Diagnosis of Breast Cancer

  • Onur, Gulcin Ozkan;Tarcan, Ercument;Onur, Asim;Can, Huseyin;Atahan, Murat Kemal;Yigit, Seyran Ceri;Cakalagaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.10
    • /
    • pp.4323-4328
    • /
    • 2015
  • Background: Breast cancer is the most common cause of deaths of cancer in women. Nowadays, following completion of imaging methods, mainly fine needle aspiration biopsy (FNAB) and core biopsy methods have been used for establishing cytopathological diagnosis although discussions regarding superiority continue. Materials and Methods: Those with a complaint of "mass in breast" along with those diagnosed to have a mass as a result of routine physical examination among all patients applying to our clinic between 01.01.2009 and 31.12.2011 were retrospectively assessed. Totals of 146 and 64 patients with complete radiological observation who had undergone FNAB and core biopsies, respectively, were evaluated. Postoperative pathological results of patients of both groups receiving surgery were also taken into consideration. All results were compared in terms of false positivity/negativity, sensitivity/specifity, surgery types and distribution of postoperative results with regard to diagnoses along with those of malignant/benign masses with regard to quadrants determined. Results: Diagnostic malignancy power of mammographic BIRADS classification was 87.3%. However, the value was 75% in the core biopsy group. Sensitivity and specifity following comparison of FNAB and postoperative pathology results of those receiving surgery were 85.4% and 92.9% while they were 93.5% and 100% in the core biopsy group. Diagnostic malignancy power, calculated by determining AUC in ROC analysis, of FNAB was 89.1% while that of core biopsy was 96.7%. Conclusions: It was shown that core biopsy is superior to FNAB in terms of sensitivity, specificity and accurate histopathological classification. However; quick, cheap and basic diagnosis by means of FNAB should not be ignored. Sensitivity of FNAB is rather high in experienced hands and furthermore it would be expected to be lower than with core biopsy.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Lymphangioma involving whole mesentery confirmed by core needle biopsy (침 생검술로 확진된 전체 장간막을 침범한 림프관종)

  • Jang, Won Young;Do, Min Young;Ahn, Byung Chan;Park, Myeong Soon;Kim, Hyun Ah;Ryu, Seong-Yeol;Kim, Sang Pyo;Park, Keon Uk
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.130-133
    • /
    • 2016
  • Lymphangiomas are malformations of the lymphatic system accounting for approximately 5% of all benign tumors in infants and children. Abdominal lymphangiomas are rare, and can arise from either the retroperitoneum, gastrointestinal tract, or the mesentery of the abdominal viscera. Lymphangioma involving the whole mesentery is particularly rare. Most lymphangiomas are detected during infancy or childhood, but intraabdominal lymphangiomas such as mesentery are not found until adulthood. We report here on a patient with uncommon lymphangioma involving the whole mesentery who presented with fever and abdominal pain. This patient is unusual because he was confirmed through core needle biopsy which showed variable sized lymphatic spaces representing a immunoreactive for D2-40 antibody with involvement of the whole mesentery. No cases of mesenteric lymphangioma confirmed preoperatively have been previously reported in Korea.

US-guided 14G Core Needle Biopsy: Comparison Between Underestimated and Correctly Diagnosed Breast Cancers

  • Kim, Hana;Youk, Ji Hyun;Kim, Jeong-Ah;Gweon, Hye Mi;Jung, Woo-Hee;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3179-3183
    • /
    • 2014
  • Background: The purpose of study was to evaluate radiologic or clinical features of breast cancer undergoing ultrasound (US)-guided 14G core needle biopsy (CNB) and analyze the differences between underestimated and accurately diagnosed groups. Materials and Methods: Of 1,898 cases of US-guided 14G CNB in our institute, 233 cases were proven to be cancer by surgical pathology. The pathologic results from CNB were invasive ductal carcinoma (IDC) (n=157), ductal carcinoma in situ (DCIS) (n=40), high-risk lesions in 22 cases, and benign in 14 cases. Among high-risk lesions, 7 cases of atypical ductal hyperplasia (ADH) were reported as cancer and 11 cases of DCIS were proven IDC in surgical pathology. Some 29 DCIS cases and 157 cases of IDC were correctly diagnosed with CNB. The clinical and imaging features between underestimated and accurately diagnosed breast cancers were compared. Results: Of 233 cancer cases, underestimation occurred in 18 lesions (7.7%). Among underestimated cancers, CNB proven ADH (n=2) and DCIS (n=11) were diagnosed as IDC and CNB proven ADH (n=5) were diagnosed at DCIS finally. Among the 186 accurately diagnosed group, the CNB results were IDC (n=157) and DCIS (n=29). Comparison of underestimated and accurately diagnosed groups for BI-RADS category, margin of mass on mammography and US and orientation of lesion on US revealed statistically significant differences. Conclusions: Underestimation of US-guided 14G CNB occurred in 7.7% of breast cancers. Between underestimated and correctly diagnosed groups, BI-RADS category, margin of the mass on mammography and margin and orientation of the lesions on US were different.

Fine Needle Aspiration Cytology vs. Core Needle Biopsy for Thyroid Nodules: A Prospective, Experimental Study Using Surgical Specimen (갑상선 결절에 대한 세침 흡인 세포 검사와 중심부 바늘 생검의 비교: 수술 검체를 기반으로 한 전향적, 실험적 비교 연구)

  • Hyuk Kwon;Jandee Lee;Soon Won Hong;Hyeong Ju Kwon;Jin Young Kwak;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.645-657
    • /
    • 2022
  • Purpose To evaluate and compare the diagnostic outcomes of ultrasonography (US)-guided fine needle aspiration (FNA) and core needle biopsy (CNB) performed on the same thyroid nodule using a surgical specimen for direct comparison. Materials and Methods We included 89 thyroid nodules from 88 patients from February 2015 to January 2016. The inclusion criterion was thyroid nodules measuring ≥ 20 mm (mean size: 40.0 ± 15.3 mm). Immediately after surgical resection, FNA and subsequent CNB were performed on the surgical specimen under US guidance. FNA and CNB cytopathologic results on the specimen were compared with the surgical diagnosis. Results Among the 89 nodules, 30 were malignant and 59 were benign. Significantly higher inconclusive rates were seen in FNA for malignant than benign nodules (80.0% vs. 39.0%, p < 0.001). For CNB, conclusive and inconclusive rates did not differ between benign and malignant nodules (p = 0.796). Higher inconclusive rates were seen for FNA among cancers regardless of US features, and in the subgroup of size ≥ 40 mm (62.5% vs. 22.9%, p = 0.028). Eleven cancers were diagnosed with CNB (36.7%, 11/30), while none was diagnosed using FNA. Conclusion In this experimental study using surgical specimens, CNB showed a potential to provide improved diagnostic sensitivity for thyroid cancer, especially when a conclusive diagnosis is limited with FNA.

Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog (개에서 초음파를 이용한 간 종괴의 세침흡인술 증례)

  • 최호정;이기창;최민철;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.