• 제목/요약/키워드: Core Specimen

검색결과 314건 처리시간 0.027초

열가압성형도재 코어의 가시광선 투과율에 관한 연구 (A study on the visible wave of transmittance pressable ceramic core)

  • 정인호;이상덕;남상용
    • 대한치과기공학회지
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

A Study on Mode I Interlaminar Fracture Toughness of Foam Core Sandwich Structures

  • Sohn, Se-Won;Kwon, Dong-Ahn;Hong, Sung-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권3호
    • /
    • pp.47-53
    • /
    • 2001
  • This paper investigates the characteristics of interlaminar fracture toughness of foam core sandwich structures under opening mode by using the double cantilever beam (DCB) specimens which are Carbon/Epoxy and foam core composites. Instead of using a DCB specimen of symmetric geometry, a non-symmetric DCB specimen was used to calculate the interlaminar fracture toughness. Three approaches for calculating the energy release rate(G$\sub$IC/) were used and fracture toughness of foam core sandwich structures made by autoclave, vacuum bagging and hotpress were compared. Experiment, analysis using nonlinear beam bending theory, and numerical work by FEM methods were performed. Bonding surface compensation and equivalent moment of inertia were used to calculate the energy release rate in nonlinear analytical work. Conclusions of experimental, nonlinear analytical and FEM methods were compared. It is, also, shown that the vacuum bagging forming can substitute the method of autoclave without serious loss of Mode I energy release rate(G$\sub$I/).

  • PDF

The Magnetic Properties of Electrical Steel for Rotating Machine according to the Specimen

  • Choi, Yun-Yong;Chin, Jun-Woo;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.209-214
    • /
    • 2016
  • This paper analyzes the magnetic property according to the machined shape of steel material with non-oriented silicon steel (50PN470/50A470), that is most commonly used in the design of electrical equipment. Toward this end, specimens were produced and divided into Bar-Specimen (Epstein Frame Tester) and Ring-Specimen (Toroidal Ring Tester). The characteristics of the electrical Silicon steel were measured using the instruments solely dedicated to measuring each specimen. The core loss of the Bar-Specimen, which is commonly used, was found to be less than that of the Ring-Specimen. This is a very important design factor in achieving the objectives of improving the product efficiency and predicting the performance of electrical equipment. It serves as a critical point of view in order to reduce the error between design value and product value. A comparative analysis was conducted regarding various characteristics (Hysteresis, B-H characteristic, Iron loss, Minor loop, Coercive force, Residual magnetic flux density, etc.) of the electrical silicon steel considered in the design of the electrical equipment according to the specimen.

변압기 철심용 Fe-B-Si비정질 합금의 철손 특성 (Core Losses of Amorphous Fe-B-Si Alloy for Transformer Core)

  • 김기욱;송재성;홍진완;강원구
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.67-72
    • /
    • 1991
  • For improving the magnetic properties of the amorphous Fe-B-Si alloy, we annealed the sample in a magnetic field oriented in the plane of the ribbon longitudinal to its long axis. By field annealing, coercive force and total core loss are reduced from 0.04 Oe to 0.02 Oe, and from 0.25 watt/kg to 0.15 watt/kg respectively in comparsion with non-field annealed specimen. These reductions were caused by the formation of 180 dcmain wall parallel to the annealing field due to the induced anisotropy.

Ti-Mo 코어-쉘 분말 제조 및 소결 특성 연구 (Fabrication of Ti-Mo Core-shell Powder and Sintering Properties for Application as a Sputtering Target)

  • 이원희;박천웅;김희연;하윤철;변종민;김영도
    • 한국분말재료학회지
    • /
    • 제31권1호
    • /
    • pp.43-49
    • /
    • 2024
  • In this study, a core-shell powder and sintered specimens using a mechanically alloyed (MAed) Ti-Mo powder fabricated through high-energy ball-milling are prepared. Analysis of sintering, microstructure, and mechanical properties confirms the applicability of the powder as a sputtering target material. To optimize the MAed Ti-Mo powder milling process, phase and elemental analyses of the powders are performed according to milling time. The results reveal that 20 h of milling time is the most suitable for the manufacturing process. Subsequently, the MAed Ti-Mo powder and MoO3 powder are milled using a 3-D mixer and heat-treated for hydrogen reduction to manufacture the core-shell powder. The reduced core-shell powder is transformed to sintered specimens through molding and sintering at 1300 and 1400℃. The sintering properties are analyzed through X-ray diffraction and scanning electron microscopy for phase and porosity analyses. Moreover, the microstructure of the powder is investigated through optical microscopy and electron probe microstructure analysis. The Ti-Mo core-shell sintered specimen is found to possess high density, uniform microstructure, and excellent hardness properties. These results indicate that the Ti-Mo core-shell sintered specimen has excellent sintering properties and is suitable as a sputtering target material.

Behavior of reinforced concrete segmental hollow core slabs under monotonic and repeated loadings

  • Najm, Ibrahim N.;Daud, Raid A.;Al-Azzawi, Adel A.
    • Structural Monitoring and Maintenance
    • /
    • 제6권4호
    • /
    • pp.269-289
    • /
    • 2019
  • This study investigated experimentally the response of thick reinforced concrete specimens having hollow cores with critical parameters. The investigation includes testing of twelve specimens that are solid and hollow-core slab models. Each specimen consists of two pieces, the piece dimensions are (1.2 m) length, (0.3 m) width and (20 cm) thickness tested under both monotonic and repeated loading. The test program is carried out to study the effects of load type, core diameters, core shape, number of cores, and steel fiber existence. Load versus deflection at mid span, failure modes, and crack patterns were obtained during the test. The test results showed that core shape and core number has remarkable influenced on cracking pattern, ultimate load, and failure mode. Also, when considering repeated loading protocol, the ultimate load capacity, load at yielding, and ductility is reduced.

Hollow core 슬래브 간 접합부의 전단저항성능 평가 (Shear Performance Evaluation of the Joint between Hollow Core Slabs)

  • 홍건호;백종삼;박홍근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.94-101
    • /
    • 2010
  • 최근 건설공사의 공기단축을 위하여 프리캐스트 콘크리트(Precast Concrete)에 대한 관심이 점차 증가하는 추세이다. 본 연구에서는 프리캐스트 콘크리트 중 내부에 중공을 설치하여 중량을 감소시킨 할로우코어 슬래브 간의 접합부 전단성능 평가에 대한 실험적 연구를 수행하였다. 실험의 주요 변수는 할로우코어 슬래브 상부의 토핑콘크리트의 두께와 와이어메쉬의 배근유무이며, 총 8개의 슬래브간 접합부 실험체 중 4개의 면내전단실험과 4개의 면외방향 전단실험을 수행하였다. 실험의 결과는 균열하중, 파괴하중, 파괴양상, 강성 및 연성도의 측면에서 분석하였으며, 실험결과를 설계하중과 비교 검토함으로써 최적의 디테일을 개발할 수 있는 실험적 근거를 제공하도록 하였다. 실험결과, 슬래브 간 접합부에 무수축 모르타르를 타설한 경우에는 토핑두께 30mm의 보통 콘크리트를 사용한 것과 유사한 구조성능을 발현할 수 있는 것으로 평가되었으며, 와이어메쉬의 보강효과는 내력 및 강성보다는 연성의 증가에 크게 기여하는 것으로 나타났다. 또한, 토핑콘크리트의 두께에 따른 설계하중과의 비교를 통하여 적절한 디테일 설계를 할 수 있는 기초적 자료를 제공하였다.

카본/에폭시 면재 및 허니컴 코어 샌드위치 복합재 구조의 구멍 손상에 의한 4점 굽힘 강도 연구 (A Study on 4 Point Bending Strength of Carbon/epoxy Face Sheet and Honeycomb Core Sandwich Composite Structure after Open Hole Damage)

  • 박현범
    • Composites Research
    • /
    • 제27권2호
    • /
    • pp.77-81
    • /
    • 2014
  • 본 연구에서는 전기체 복합재가 적용되어 설계된 소형 항공기의 손상 평가 및 유지 보수 연구를 수행하였다. 본 연구에서 개발 중인 항공기의 스킨 부위는 샌드위치 구조가 적용되었다. 본 연구에서는 노멕스 허니컴코어와 카본 면재가 적용된 샌드위치 복합재 구조에 대해 구멍 손상 이후의 잔류 강도 평가에 대한 연구를 수행하였다. 4점 굽힘 시험을 통해 시편의 굽힘 강도를 확인하고, 시편에 손상을 모사하기 위하여 시편의 중앙 부위에 구멍 손상을 가하였다. 손상된 시편을 손상 전 시편과 동일한 시험을 통해 손상 전의 강도와 비교하였다. 또한 손상된 복합재 구조는 손상 부위 제거 후 패치 수리 기법을 적용하고 손상된 시편과 보수된 시편의 굽힘 강도 시험결과를 비교하였다. 샌드위치 복합재 구조 시편의 유지 보수 후 굽힘 강도 시험 결과 손상 전 시편의 강도와 비교하여 강도의 95%까지 회복되는 것으로 분석되었다.

700 MPa급 고강도 및 내진 철근의 미세조직과 인장 특성 (Microstructure and Tensile Properties of 700 MPa-Grade High-Strength and Seismic Resistant Reinforced Steel Bars)

  • 홍태운;이상인;황병철
    • 한국재료학회지
    • /
    • 제28권7호
    • /
    • pp.391-397
    • /
    • 2018
  • This study deals with the microstructure and tensile properties of 700 MPa-grade high-strength and seismic reinforced steel bars. The high-strength reinforced steel bars (600 D13, 600 D16 and 700 D13 specimens) are fabricated by a TempCore process, while the seismic reinforced steel bar (600S D16 specimen) is fabricated by air cooling after hot rolling. For specimens fabricated by the TempCore process, the 600 D13 and 600 D16 specimens have a microstructure of tempered martensite in the surface region and ferrite-pearlite in the center region, while the 700 D13 specimen has a microstructure of tempered martensite in the surface region and bainite in the center region. Therefore, their hardness is the highest in the surface region and shows a tendency to decrease from the surface region to the center region because tempered martensite has a higher hardness than ferrite-pearlite or bainite. However, the hardness of the 600S D16 specimen, which is composed of fully ferrite-pearlite, increases from the surface region to the center region because the pearlite volume fraction increases from the surface region to the center region. On the other hand, the tensile test results indicate that only the 700 D13 specimen with a higher carbon content exhibits continuous yielding behavior due to the formation of bainite in the center region. The 600S D16 specimen has the highest tensile-to-yield ratio because the presence of ferrite-pearlite and precipitates caused by vanadium addition largely enhances work hardening.

Variability of Fatigue Crack Initiation Life in Flux Cored Arc Welded API 2W Gr.50 Steel Joints

  • Sohn, Hye-Jeong;Kim, Seon-Jin
    • International Journal of Ocean System Engineering
    • /
    • 제2권3호
    • /
    • pp.160-169
    • /
    • 2012
  • Flux Cored Arc Welding (FCAW) is a common practice to join thick plates such as the structural members of large scale offshore structures and very large container ships. The objective of this study was to investigate the mechanical properties and variability of the fatigue crack initiation life in the flux cored arc welded API 2W Gr.50 steel joints typically applied to offshore structures with a focus on the effect of the materials in fatigue crack growth life from the notch root of a compact tension specimen. Offshore structural steel (API 2W Gr.50) plates (60-mm thick) were used to fabricate multi-path flux core arc welded butt welded joints to clearly consider fatigue fractures at the weld zone from the notch. Fatigue tests were performed under a constant amplitude cyclic loading of R = 0.4. The mean fatigue crack initiation life of the HAZ specimen was the highest among the base metal (BM), weld metal (WM), and heat affected zone (HAZ). In addition, the coefficient of variation was the highest in the WMl specimen. The variability of the short fatigue crack growth rates from the notch tips in the WM and HAZ specimens was higher than in BM.