• 제목/요약/키워드: Copper wastewater

검색결과 98건 처리시간 0.02초

BPBE Cell에 의한 중금속함유폐수처리 (Electrolytic Treatment of Heavy Metallic ion Wastewater by BPBE Cell)

  • 장철현;박재주;박승조;김수생
    • Environmental Analysis Health and Toxicology
    • /
    • 제4권3_4호
    • /
    • pp.29-59
    • /
    • 1989
  • For the purpose of electrolytic treatment of wastewater containing various heavy metals, the BPBE Cell of batch and continuous type was considered and experimented. Some results from this study were summarized as follows: 1. When the artificial wastewater containing 500 mg/l of the concentration of various heavy metallic ion was electrolyzed in BPBE Cell of batch type, the removal efficicency was over 95% in cadmiun (II), lead (II), chromium (Ⅵ) and over 85% in copper (II), chromium (III). 2, As granular activated carbon packed in BPBE Cell, coconut shell was superior to lignite and the removal efficiency was the highest when the activated carbon was 4/6 mesh, the voltage was 20V. 3. When the heavy metallic ion in wastewater was electrolyzed in BPBE Cell of continuous type, about 1,000mg of heavy metal per 1kg of coconut sell could be removed. 4. The treatment method of heavy metallic ion in wastewater by BPBE Cell cost less than in the former chemical treatment method and the coconut shell packed in BPBE Cell could be regenerated by chemical method.

  • PDF

배·급수계통에서 유리염소와 클로라민의 소독효과에 관한 비교연구 (Comparative Study on Disinfection Efficiency of Chlorine and Chloramine in the Distribution Systems)

  • 최용일;남상호
    • 상하수도학회지
    • /
    • 제13권2호
    • /
    • pp.82-88
    • /
    • 1999
  • This study was to evaluate disinfection efficiency of chlorine and chloramine as secondary disinfectants in the distribution systems. Indicator organism, HPC in the suspended and attached were measured for copper, galvanized steel, PVC, and carbon steel pipes. For suspended microorganism, the PVC pipe was markedly dense among the assessed pipe materials. The attached microorganism was markedly equivalent roughness of pipe materials. In copper and galvanized pipes, chloramine was more effective that free chlorine to disinfect suspended microorganism in the contact time of 2 hours. The contact time for the 99% inactivation of suspended microorganism by chloramine was longer than that of free chlorine. Regardless of pipe materials, chloramine was effective on both disinfection efficiency and 99% inactivation time for attached microorganism. In conclusion, chloramine which is good disinfectant for long contact time was recommended as secondary disinfectant in distribution system.

  • PDF

특정제조업 폐수처리시설에 대한 신뢰성 평가 (Reliability Assessment of Industrial Wastewater Treatment Plant)

  • 양형재;김재훈;이성종
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.1-9
    • /
    • 2007
  • A wastewater treatment plant, operating process is physico-chemical/biological activated sludge attached sand filtration, was selected to evaluate effluent quality and pollutants removal efficiencies consideration for deriving the technology-based effluent limitation for petroleum refining industry discharge. The results of influent and effluent analysis were as follows: Average effluent quality were 0.076mg/l of copper, 0.084mg/l of lead, 0.036mg/l of zinc, 0.005mg/l of nickel and 0.004mg/l of cadmium, and the range of coefficient of reliability from 0.007 of copper to 1.0 of lead. Also, 95% of reliability, 0.112, 0.15, 0.063, 0.015 and 0.009mg/l, respectively, were remarkably lower than their effluent limitations. And to reach 95% reliability of effluent limitation at cleanness area, designed effluent quality of copper, lead, zinc and cadmium should be 0.268, 0.099, 0.526 and 0.008mg/l, respectively.

Electrolyte Addition for Enhanced Wastewater Treatment by Electrolysis using Cu Electrode

  • Kim, Woo-Yeol;Yun, Chan-Young;Son, Dong-Jin;Chang, Duk;Kim, Dae-Gun;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권1호
    • /
    • pp.35-42
    • /
    • 2017
  • In this study, the effect of electrolyte addition on the removal of organics and nutrients in electrochemical wastewater using a copper electrode, and the characteristics of the by-product of electrolysis were investigated. The removal of organics increased significantly as shorter reaction times upon the addition of chloride ion, and most of the electrolysis reaction was completed within 20 min. The reaction rate gradually increased in proportion to the $Cl^-$/COD ratio, whereas the highest removed mass of organic matter per mass of added electrolyte was observed at a $Cl^-$/COD ratio of 1. After the addition of electrolyte, significant removal of ammoniacal nitrogen was observed as a result of the enhanced generation of oxidizers such as hypochlorite. Excellent phosphorus removal was also achieved in a very short reaction time (within 2 min) by electro-coagulation. As the electrolysis progressed, the amount of by-product increased gradually, whereas a decrease of sludge volume index was observed after the addition of electrolyte. This indicated that the settling performance of the by-products was better, and their removal would be easily achieved.

Tyromyces palustris를 이용한 구리의 제거 (Copper Uptake by Tyromyces palustris)

  • 손동원;이동흡;강창호
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권1호
    • /
    • pp.57-62
    • /
    • 1998
  • In this research, the removal or uptake of heavy metals such as coppers by using oxalic acid metabolism of wood rot fungi, Tyromyces palustris were endeavored. As results, the addition of oxalic acid to copper containing culture did not cause the mycelium growth, but Tyromyces palustris was able to grow in this culture without inhibition. Tyromyces palustris grew with the cicular halo type in copper containing culture, and this type was formed as collectives after examining by microscope, and considered as copper oxalates by analyzing FT-IR comparison experiment with standards. According to this result, Tyromyces palustris has secreted oxalic acid during incubation, this secreted oxalic acid was combined with coppers, and formed copper oxalates by chelating reactions. In other words, the oxalic acid was might be as non-toxifying agent of coppers in medium. By using this copper removal mechanisms, Tyromyces palustris immobilized sawdust was used in bench scale air lift system for removing coppers. The added coppers were almost removed from the system within 72hrs. Therefore, this nonenzymatic wood degradation mechanism may give a possibility for removing coppers from copper containing waste water.

  • PDF

Electrodialysis of metal plating wastewater with neutralization pretreatment: Separation efficiency and organic removal

  • Park, Yong-Min;Choi, Su-Young;Park, Ki-Young;Kweon, Jihyang
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.179-187
    • /
    • 2020
  • Electrodialysis has been applied for treatment of industrial wastewater including metal electroplating. The wastewater from metal plating industries contains high concentrations of inorganics such as copper, nickel, and sodium. The ions in the feed were separated due to the electrical forces in the electrodialysis. The concentrate compartment is exposed to the elevated concentrations of the ions and yielded inorganic precipitations on the cation exchange membranes. The presence of organic matter in the metal plating wastewater affects complex interfacial reactions, which determines characteristics of inorganic scale fouling. The wastewater from a metal plating industry in practice was collected and the inorganic and organic compositions of the wastewater were analyzed. The performance of electrodialysis of the raw wastewater was evaluated and the effects of adjusting pH of the raw water were also measured. The integrated processes with neutralization and electrodialysis showed great removal of heavy metals sufficient to discharge to aquatic ecosystem. The organic matter in the raw water was also reduced by the neutralization, which might enhance removal performance and alleviate organic fouling in the integrated system.

산업도금폐수 처리에 사용된 탄소폼 흡착소재의 중금속 탈착 및 회수에 관한 연구 (Study on Heavy Metal Desorption and Recovery of the Carbon Foam used in Industrial Plating Wastewater Treatment as Adsorbent)

  • 이다영;이창구;김대운;박상현;권지향;이상협
    • 대한환경공학회지
    • /
    • 제38권11호
    • /
    • pp.627-634
    • /
    • 2016
  • 본 연구에서는 탄소폼 흡착소재를 이용하여 산업도금폐수로부터 중금속을 흡착 제거한 후 탈착용액을 이용하여 제거된 중금속을 용출하고 회수하는 과정의 특성을 평가해 보고자 하였다. 용액의 조성에 따른 복합 중금속의 탈착 특성을 살펴본 결과 증류수 조건에서는 용출이 관측되지 않았으며, 탈착용액으로 HCl과 $H_2SO_4 $를 이용한 경우 높은 중금속 농도를 나타내었다. 탈착 용액을 이용함과 더불어 물리적 기술인 초음파 처리를 이용한 경우 중금속의 용출이 증진되는 것을 확인하였으며, 초음파 장치의 출력이 높고 반응 시간이 길수록 효율도 증가하는 것으로 나타났다. 탄소폼 흡착소재를 구리도금 세척수 처리에 적용시켜본 결과 200 반응기부피(Bed volume) 동안 안정적인 제거 성능을 나타내었으며, 흡착된 구리는 탈착용액을 이용하여 용출시킨 후 직류 전원 장치를 이용하여 회수할 수 있었다. 또한 구리가 회수된 탈착용액은 재이용 효율은 84.2%로 나타났다.

무전해(無電解) 구리 도금폐액(鍍金廢液)으로부터 구리의 회수(回收) 연구(硏究) (Recovery of Copper in Wastewater from Electroless Plating Process)

  • 이화영;고현백
    • 자원리싸이클링
    • /
    • 제21권6호
    • /
    • pp.39-44
    • /
    • 2012
  • 무전해 구리 도금폐수로부터 증발농축 및 전해채취법을 이용하여 구리를 회수하기 위한 연구를 수행하였다. 무전해 구리 도금폐수의 분석결과, Cu 함량은 582 mg/l로 나타났으며, 미량의 Fe 성분이 함유되어 있었다. 또한, 로셀염의 첨가로 인하여 COD 9,560 mg/l, TOC 13,100 mg/l로써 매우 높았으며, 포름알데히드가 산화된 formic acid의 함량은 7.73%로 나타났다. 실험결과, 구리의 전해채취시 전류밀도가 증가할수록 전류효율은 감소하는 것으로 나타났다. 또한, 전류효율을 80% 이상으로 유지하기 위해서는 구리의 전해채취시 전류밀도를 $40mA/cm^2$ 이하로 낮추어야 함을 알 수 있었다. 전해채취를 통해 얻은 Cu중의 평균 Fe 함량은 황산농도 2 vol% 및 10 vol%에서 각각 0.021% 및 0.01%로 나타나 황산농도가 높을수록 Fe 혼입을 억제할 수 있는 것으로 나타났다.

Recovery of Heavy Metals using Oxidized Undaria pinnatifida in Plating Wastewater

  • 박재연;전충;유영제
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.357-360
    • /
    • 2000
  • Biosorption process is an economic and potential process for metal sequestering from the water. The oxidized Undaria pinnatifida by nitric acid had high uptake capacity for heavy metals of 4 - 6 meq / g dry mass. For the application of oxidized Undaria pinnatifida, recovery of metal in plating wastewater was studied. The uptake capacity of the oxidized Undaria pinnatifida was high compared to the ion exchanger IR-120 plus. The treatment efficiency of chromium and copper in the wastewater was 85% In batch. Activated carbon was used to assist the recovery of water by removing organic matters of the wastewater.

  • PDF

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.