• 제목/요약/키워드: Copper removal

검색결과 330건 처리시간 0.025초

가스취입에 의한 용융 동 합금 중 납의 증발속도 (Evaporation Rate of Lead in Molten Copper Alloy by Gas Injection)

  • 김항수;정성엽;정우광;윤의한;손호상
    • 한국재료학회지
    • /
    • 제12권1호
    • /
    • pp.68-74
    • /
    • 2002
  • The lead has to be removed for the recycling of copper alloy. The lead cannot be removed from the copper alloy by oxidation. It can be removed by the evaporation because of its high vapor pressure. However, rare information is found on removal of lead from copper alloy. The purpose of present work is to provide a fundamental knowledges on the removal of lead from the copper alloy by evaporation. Gas injection was made in molten copper alloy, and the evaporation rate of lead was measured. The influence of Ar gas flow rata(2~4 L/min), initial contents of lead(2~4wt%Pb), temperature(1200~140$0^{\circ}C$) was investigated based on the thermodynamic and the kinetics. The rate constant is increased with increasing flow rate of Ar and temperature. Though amount of lead removed is increased with higher initial lead concentration, the rate constant is not changed significantly. The activation energy is estimated from the temperature dependence of the rate constant. Also removal of lead from the copper by adding chloride was made for the comparison.

표면개질된 소나무 수피를 이용한 수용액의 구리이온 흡착 (Adsorption of copper ions from aqueous solution using surface modified pine bark media)

  • 박세근;김영관
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.131-140
    • /
    • 2019
  • This study used a packed column reactor and a horizontal flow mesh reactor to examine the removal of copper ions from aqueous solutions using pine bark, a natural adsorbent prepared from Korean red pine (Pinus densiflora). Both equilibrium and nonequilibrium adsorption experiments were conducted on copper ion concentrations of 10mg/L, and the removals of copper ions at equilibrium were close to 95%. Adsorption of copper ions could be well described by both the Langmuir and Freundlich adsorption isotherms. The bark was treated with nitric acid to enhance efficiency of copper removal, and sorption capacity was improved by about 48% at equilibrium; mechanisms such as ion exchange and chelation may have been involved in the sorption process. A pseudo second-order kinetic model described the kinetic behavior of the copper ion adsorption onto the bark. Regeneration with nitric acid resulted in extended use of spent bark in the packed column. The horizontal flow mesh reactor allowed approximately 80% removal efficiency, demonstrating its operational flexibility and the potential for its practical use as a bark filter reactor.

계면활성제 (SDS, Tween 80)와 HCl을 활용한 중금속 오염 토양의 복원 (HCl, Surfactant (SDS, Tween 80) Enhanced Remediation of Contaminated Soil with Lead and Copper)

  • 조미영;현재혁;백정선
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1999년도 추계학술발표회
    • /
    • pp.12-15
    • /
    • 1999
  • Soils collected from an agricultural field in Youngdong, Chungbuk province were intentionally: contaminated with lead and copper. The efficiencies of soil washing with HCl, SDS and Tween 80 were investigated through the column mode experiments. Washing with 0.1 N HCl obtained the best result for lead and copper removal (95.04 %, 95.94 %). In case of SDS, lead and copper removal rate was such poor as 7.1 % and copper was 24.04 %, respectively. Meanwhile, washing of contaminated soil with Tween 80, did not show any significant removal effect. It was found that the washing efficiency was dependent on pH of washing agent.

  • PDF

Microfiltration/ultrafiltration polyamide-6 membranes for copper removal from aqueous solutions

  • El-Gendi, Ayman;Ali, Sahar;Abdalla, Heba;Saied, Marwa
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.55-70
    • /
    • 2016
  • Microfiltration/ultrafiltration (MF/UF) Adsorptive polyamide-6 (PA-6) membranes were prepared using wet phase inversion process. The prepared PA-6 membranes are characterized by scanning electron microscopy (SEM), porosity and swelling degree. In this study, the membranes performance has examined by adsorptive removal of copper ions from aqueous solutions in a batch adsorption mode. The $PA-6/H_2O$ membranes display sponge like and highly porous structures, with porosities of 41-73%. Under the conditions examined, the adsorption experiments have showed that the $PA-6/H_2O$ membranes had a good adsorption capacity (up to 120-280 mg/g at the initial copper ion concentration ($C_0$) = 680 mg/L, pH7), fast adsorption rates and short adsorption equilibrium times (less than 1.5-2 hrs) for copper ions. The fast adsorption in this study may be attributed to the high porosities and large pore sizes of the $PA-6/H_2O$ membranes, which have facilitated the transport of copper ions to the adsorption. The results obtained from the study illustrated that the copper ions which have adsorbed on the polyamide membranes can be effectively desorbed in an Ethylene dinitrilotetra acetic acid Di sodium salt ($Na_2$ EDTA) solution from initial concentration (up to 92% desorption efficiency) and the PA-6 membranes can be reused almost without loss of the adsorption capacity for copper ions. The results obtained from the study suggested that the $PA-6/H_2O$ membranes can be effectively applied for the adsorptive removal of copper ions from aqueous solutions.

중금속폐수에서 구리의 전기화학적 침전처리 (Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater)

  • 김재우;이재동;이우식;지은상
    • 한국환경보건학회지
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.

자궁내피임장치 카파티 380A에 관한 임상적 고찰 (Clinical Expenience with Copper T 380A Intrauterine Contraceptive Device)

  • 배병주;황영환
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제21권2호
    • /
    • pp.221-226
    • /
    • 1994
  • Copper T 380A intrauterine devices were inserted to nine thousand and nine hundred twenty women by 51 KAVS-member physicians since January 1, 1993 through December 31, 1993. This study was undertaken for the clinical analysis on a total of 9,920 women wearing Copper T 380A to grasp the effectivness as well as the expulsion rate due to a various side effects. The following features were the results of the study: 1. During the twelve months period, from January 1993 to December 1993, the largest number of IUD insertion per one physician is 740 cases and the smallest number 60 cases, the mean 195 cases. 2. After insertion of Copper T 380A, a total of 117 cases were removed the IUD;81 cases(0.8%) were due to extensive bleeding and 36 cases(O.36%) were due to pain. The pregnancy failure rate represented comparatively lower rate, 0.08% (8 cases) and the expulsion rate was 0.06%(6 cases). 3. The removal rate of Copper T 380A was different by physicians. The highest removal rate for bleeding was 3.13% and 13 physicians(25.5%) did not experience any bleeding cases. 4. For the removal rate for pain, 30 physicians(58.8%) did not experience any removal of IUD due to pain while 21 physicians(41.2%) removed IUD due to pain: 17 physiciansC33.4 %) had 0.1-1.5% of removal rate and 4 physiciansC7.0%) had 1.6-2.1% of removal rate. 5. A total of 43 physicians(84.3 %) did not experience any pregnancy failure case while 8 (15.7%) physicians was experienced pregnancy failure rate. Four physicians(7.8%) had 0.1-0.5% of pregnancy failure rate and 4 physicians had 0.6-1.0% of pregnancy failure rate. 6. Expulsion rate showed comparatively lower, 0.06% in this study. A total of 45 physicians (88.2%) did not experience any expulsion cases while 6 physicians(11.7%) had expulsion rate with the highest expulsion rate of 2.0%.

  • PDF

생물학적인 방법을 이용한 방부처리재의 중금속 제거 (II) - CCA, CCFZ 처리재에서 중금속 제거 - (The Removal of Heavy Metals from Treeated Wood by Biological Methods (II) - Removal of Heavy metals from CCA and CCFZ- treated Wood -)

  • 손동원;이동흡;강창호
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권2호
    • /
    • pp.1-8
    • /
    • 2004
  • 갈색부후균 Tyromyces palustris를 이용하여 CCA처리 목재와 CCFZ처리 목재에서 중금속을 제거하였다. 전처리 방법으로써 증기압처리와 수산처리가 검토되었다. 수산 전처리에 의한 균처리의 제거율 상승 영향과 일정 균체량에 대한 방부처리재의 폭로양의 차이에 따른 처리율의 변화정도를 검토하였다. 배양방법을 달리하여 방부처리재의 유효성분 제거량을 비교하고 생물반응기를 이용하여 중금속 제거를 실시하였다. 크롬과 비소는 수산의 농도가 증가할수록 제거율이 증가하였으나 구리는 농도의 증가에 따른 제거율이 크게 향상되지 않았다. T. palustris는 균체량 287 mg으로 크롬과 비소는 시료무게 3 g까지 60% 이상의 제거율을 나타냈고 구리는 50% 이상의 제거율을 나타내었다. 진탕배양에서는 크롬, 구리, 비소의 제거율이 60% 이상의 제거율을 보였으며, 정치배양에서는 구리의 제거율이 진탕배양보다 높게 나타났다. 생물반응기 적용 시 7일 배양이후 제거율은 크롬 72%, 구리 61%, 비소는 59%이었다.

Water treatment sludge for removal of heavy metals from electroplating wastewater

  • Ghorpade, Anujkumar;Ahammed, M. Mansoor
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.92-98
    • /
    • 2018
  • Suitability of aluminium-based water treatment sludge (WTS), a waste product from water treatment facilities, was assessed for removal of heavy metals from an electroplating wastewater which had high concentrations of copper and chromium along with other heavy metals. Batch tests with simulated wastewater in single- and multi-metal solutions indicated the influence of initial pH and WTS dose on removal of six metals namely Cu(II), Co(II), Cr(VI), Hg(II), Pb(II) and Zn(II). In general, removal of cationic metals such as Pb(II), Cu(II) and Zn(II) increased with increase in pH while that of anionic Cr(VI) showed a reduction with increased pH values. Tests with multi-metal solution showed that the influence of competition was more pronounced at lower WTS dosages. Column test with diluted (100 times) real electroplating wastewater showed complete removal of copper up to 100 bed volumes while chromium removal ranged between 78-92%. Other metals which were present in lower concentrations were also effectively removed. Mass balance for copper and chromium showed that the WTS media had Cu(II) and Cr(VI) sorption capacities of about 1.7 and 3.5 mg/g of dried sludge, respectively. The study thus indicates that WTS has the potential to be used as a filtration/adsorption medium for removal of metals from metal-bearing wastewaters.

텅스텐 슬러리를 사용한 Cu-CMP 특성에서 산화제 첨가의 영향 (Effects of Oxidizer Additive on the Performance of Copper-Chemical Mechanical Polishing using Tungsten Slurry)

  • 이우선;최권우;이영식;최연옥;오용택;서용진
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.156-161
    • /
    • 2004
  • We investigated the effects of oxidizer additive on the performance of Cu-CMP process using commonly used tungsten slurry. In order to compare the removal rate and non-uniformity as a function of oxidizer contents, we used alumina-based tungsten slurry and copper blanket wafers deposited by DC sputtering method. According to the CMP removal rates and particle size distribution, and the microstructures of surface layer by SEM image as a function or oxidizer contents were greatly influenced by the slurry chemical composition of oxidizers. The difference in removal rate and roughness of copper surface are believed to cause by modification in the mechanical behavior of $Al_2$O$_3$abrasive particles in CMP slurry.