• Title/Summary/Keyword: Copper release

Search Result 43, Processing Time 0.026 seconds

Adsorption Characteristics of Copper Ion onto a Bentonite (벤토나이트에 의한 구리이온의 흡착특성)

  • Goh, E.O.;Lee, J.O.;Cho, W.J.;Hyun, J.H.;Kang, C.H.;Chun, K.S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.83-89
    • /
    • 2000
  • Bentonite has been considered as a liner material to restrict the release of hazardous heavy metals from the landfill. The adsorption of copper onto a domestic bentonite was studied to provide the adsorption isotherm and the effect of solution chemistry and temperature. The copper adsorption was fitted well to a Freundlich isotherm, in which Freundlich constants and correlation coefficient were calculated to be $K_F=1.18$, n=1.65, and $r^2=0.97$, respectively. The distribution coefficients ($K_d$) for the adsorption of copper decreased with increasing initial copper concentration. The $K_d$ increased with increasing the pH of solution, and drastically increased at pH > 5.3 because of precipitation of most copper species. As the ion strength of $Na^+$ in solution increased the $K_d$ decreased, while it increased with increasing the concentration of $SO_4{^{2-}}$ in solution. An increase in the temperature of experimental solution decreased the $K_d$ values.

  • PDF

Corrosion control of drinking water pipes by corrosion inhibitor (부식억제제에 의한 상수도관의 부식제어)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2306-2310
    • /
    • 2010
  • Corrosion is a complex series of oxidation/reduction reactions between at the water-metal surfaces and materials in which the water is stored or transported. With respect to the corrosion potential of drinking water, the primary concerns include the potential presence of toxic metals, such as lead and copper; deterioration and damage to the household plumbing, and aesthetic problems such as stained laundry, and bitter taste. This study was performed to evaluate the effects of corrosion inhibitors on corrosion rates, Fe and Cu release concentration in water distribution pipes. Decrease of corrosion rates were strongly related to phosphate corrosion inhibitors. Considering that typical corrosion processes consists of a series of electrochemical reaction at the metal surface in contact with water, corrosion rates were positively correlated with Fe release.

Characteristics of the release of chromium, copper, and arsenic from CCA-treated wood exposed to the natural environment (자연환경에 노출된 CCA 방부목재로부터 크롬, 구리 및 비소의 용탈 특성)

  • Koo, Jinhoi;Song, Byeongyeol;Kim, Hekap
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study was conducted to investigate the characteristics of the leaching of metal components from CCA-treated wood during outdoor exposure. CCA-treated wood specimens were placed horizontally or buried vertically into the soil, and then exposed to the natural environment for a year. Wood samples were collected from the side of the horizontal wood specimens using a drill and saw dust samples were collected at the end of the exposure. Soil samples were also obtained around the wood specimens and at different depths of the posts. Wood and soil samples were analyzed for metals using an atomic absorption spectrometer. Monthly metal concentrations varied greatly and more metals were released when wood specimens were exposed vertically than horizontally. Arsenic was released from the wood by 80 % of the intial content. In addition, more leaching was observed from the zone below the ground than above the ground, and soil around the posts was contaminated with metals released from CCA-treated wood.

Effect of Higher Frequency of Pulse Current on Copper Microstructure (고주파수 펄스 전류가 구리 미세조직에 미치는 영향)

  • Park, Chae-Min;Lee, Hyo-Jong;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.159-159
    • /
    • 2015
  • 금속의 기계적 강화방법인 결정립미세화의 일종으로 미세한 쌍정을 도입하여 기계적강도를 향상시키면서 전기전도도는 감소시키지 않는 방안으로 nanotwin 구조의 Cu가 보고되고 있다. Nanotwin 구조는 FCC결정구조에서 특정 결정면을 [(111) mirror plane]을 기준으로 정합계면을 유지하면서 원자층의 배열이 역전되는 구조가 수~수십나노 수준의 간격으로 이뤄진 미세조직을 의미한다. 전해도금법을 이용한 nanotwin Cu의 형성방법으로는 pulse 파형을 사용하는데, pulse파형의 on time동안의 높은 전류밀도로 인해 발생한 도금층의 stress가 off time동안에 release되면서 nanotwin구조가 형성되는 것으로 보고되고 있다. Nanotwin형성 조건으로 보고된 pulse 도금 조건은 수에서 수십밀리초의 on time에 duty cycle($t_{on}/(t_{off}+t_{on})$)이 1/100~1/10 수준이다. 본 연구에서는 전기이중층의 이온고갈에 필요한 회복시간인 수에서 수십 밀리초 보다 짧은 시간인 마이크로 초($1{\mu}s$, $10{\mu}s$$100{\mu}s$)의 pulse 전류를 인가하였을 때에 발생하는 구리 도금층의 미세조직의 변화에 대해 알아보고자 한다.

  • PDF

Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire (전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구)

  • Lee, Gye-Hyeong;Cho, Jin-Hyoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.127-136
    • /
    • 2005
  • The purpose of this study was to examine the cytotoxicity of orthodontic wire which had an increased diameter through electroplating, and to evaluate its possible clinical applications, First. nickel plating was carried out on the commercially available stainless steel wire using an electroplating technique For the comparison of the electroplated wire with ready made stainless steel wire and titanium or copper. each wire was incubated for 72 hours in a medium. The release of the metal ion was measured using ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrophotometer). Balb/c 3T3 mouse fibroblast was put on a microplate and placed in an incubated medium of 75%, 50%, and 20% dilation. An MTT analysis was used to compare with the medium only. The change in absorbency value of each wire group and the difference of absorbency value according to the change of dilution was measured The results of ICP-AES analysis showed that great amount nickel iou was isolated from electroplated orthodontic wires and great amount copper ion was isolated from copper. The results of the MTT analysis showed that there was no difference in the absorbency value of titanium at any dilution. However, the electroplated wires (p<0.001) the stainless steel wires (p<0.05) and the copper (P<0.001) were statistically significantly lower than those of medium only at all dilutions. Assessment as per ISO 10993, part 5, showed that electroplated wire was alloted to 'moderate cytotoxic' the titanium and stainless steel wire were 'non-cytotoxic' The results of this study indicate that the electroplated orthodontic wires need additional efforts to decrease cytotoxicity for their clinical applications.

The Heavy Metals Recovery from Carbonized CCA Treated Wood (CCA방부목재의 탄화가 중금속 회수에 미치는 영향)

  • Son, Dong-won;Cheon, Seon-Hae;Lee, Myung Jae;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.6 s.134
    • /
    • pp.95-100
    • /
    • 2005
  • The using amount of preservative-treated wood equipments has been increased. Specially, chromate copper arsenate (CCA) has been widely used to exterior wood. We are faced to the disposal problem after service period of CCA treated wood due to its toxic heavy metals. For the disposal of end-used treated wood, land-filling and incinerating methods are mainly applied. The essential problem of incinerating is an arsenic release into atmosphere. Low pyrolysis is suggested as the methods of protecting arsenic release during incineration. The heavy metals were recovered after combustion of the treated wood at the low temperature which arsenic can not released. The recovery amounts of effectiveness compounds was determined in various solvents (citric acid, nitric acid, sulfuric acid, acetic acid, phosphoric acid) and different temperature (300, 400, $500^{\circ}C$). The higher temperature was applied, the more copper was recovered. The chromium was difficult to be recovered on the carbonized CCA treated wood at 0.5% acid concentration. The recovery mass of arsenic decreased on the higher combustion treated wood. The recovery of chromium was difficult due to the chemical change of the chromium arsenate during pyrolysis.

Applicability Test of Various Stabilizers for Heavy Metals Contaminated Soil from Smelter Area (제련소 주변 오염토양의 중금속 안정화를 위한 다양한 안정화제의 적용성 연구)

  • Jeon, Jonwon;Bae, Bumhan;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.63-75
    • /
    • 2010
  • There are several remediation technologies for heavy metal contaminated soils but increasing cost limits the application of the technology if the contaminated area is large. Therefore, stabilization, which blocks the release of heavy metals or makes slow the release, is one of the applicable technology for the heavy metal contaminated soil. Current study is an applicability test for a smelter area with various stabilizer such as magnetite, hematite, zeolite-A, zeolite-X, zeolite-Y, zinc oxide, calcium oxide, carbon trioxide, manganese oxide, manganese dioxide, fish bone, sodium phosphate. The soil contaminated with arsenic, lead, copper, nickel, and zinc could not be stabilized only one stabilizer which is known to have stability for certain metal. Many of the stabilizer works for a few metal but not all of the heavy metal. In several cases, stabilizers increase the release of the other metals while they stabilize some metals. In general, the stabilizing efficiency was increased with time. For Ni, Pb, calcium oxide, carbon trioxide, manganese oxide had good stabilizing effect in water extractable portion. For Cu, manganese oxide, zeolite showed good results especially in the exchangeable portion of the sequential extraction. For As, magnetite had good ability but most of the metal oxide which showed good result for other heavy metals increased with the release of As. Current study suggest that multiple stabilizers are needed for the contaminated soil and dose of the stabilizer and stabilizing time should be carefully considered for the soil contaminated with various metals.

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.

Growth inhibition of hydrotrope-combined copper against Microcystis aeruginosa and evaluation of its toxicity (Microcystis aeruginosa에 대한 hydrotrope-combined copper의 생장억제 및 독성 평가)

  • Park, Se-Keun;Ji, Jun-Gu;Jang, Hee Jung;Kim, Yeong-Kwan;Oh, Young-Sook;Choi, Sung-Chan
    • Korean Journal of Microbiology
    • /
    • v.51 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • Hydrotrope-combined copper (HCC) is a copper ($Cu^{2+}$)-based algicide, which is combined with a hydrotrope that keeps copper ion in solution to improve performance. This study assessed the growth inhibition effect of HCC against Microcystis aeruginosa which is one of the most common toxic cyanobacterium in eutrophic freshwater environment. Various HCC doses, ranging from 5.5 to $550{\mu}g/L$ as $Cu^{2+}$, were applied to either BG-11 or 1/4 diluted medium with low- or high-inoculum density of M. aeruginosa. Growth inhibition was monitored based on a decrease in chlorophyll-a content in culture medium during the incubation. Results showed that HCC significantly inhibited the growth of M. aeruginosa in a dose-dependent manner. In case of 1/4 diluted BG-11 medium, HCC dose as low as $5.5{\mu}g$ $Cu^{2+}/L$ completely inhibited the production of chlorophyll-a by M. aeruginosa. It was found that HCC did not induce any significant release of microcystin-LR from M. aeruginosa. Acute toxicity of HCC was tested using Daphnia magna, and the 24-h $EC_{50}$ value was 0.30 mg/L as $Cu^{2+}$ which was much higher than the actual inhibition dose. Ames test was performed using Salmonella enterica serovar Typhimurium TA100, and HCC showed no increase in the number of revertant colonies. The result suggested that HCC does not have any mutagenic potential in the aquatic environment. In addition, no genotoxic effect of HCC was also confirmed based on the SOS ChromoTest using Escherichia coli PQ37. Therefore, HCC could be used as a relatively safe and effective pre- and post-treatment agent to control hazardous algal blooming in aquatic environments.

Power Absorption Measurements during NMR Experiments

  • Felix-Gonzalez, N.;Urbano-Bojorge, A.L.;de Pablo, C. Sanchez-L;Ferro-Llanos, V.;del Pozo-Guerrero, F.;Serrano-Olmedo, J.J.
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • The heating produced by the absorption of radiofrequency (RF) has been considered a secondary undesirable effect during MRI procedures. In this work, we have measured the power absorbed by distilled water, glycerol and egg-albumin during NMR and non-NMR experiments. The samples are dielectric and examples of different biological materials. The samples were irradiated using the same RF pulse sequence, whilst the magnetic field strength was the variable to be changed in the experiments. The measurements show a smooth increase of the thermal power as the magnetic field grows due to the magnetoresistive effect in the copper antenna, a coil around the probe, which is directly heating the sample. However, in the cases when the magnetic field was the adequate for the NMR to take place, some anomalies in the expected thermal powers were observed: the thermal power was higher in the cases of water and glycerol, and lower in the case of albumin. An ANOVA test demonstrated that the observed differences between the measured power and the expected power are significant.