• Title/Summary/Keyword: Coordination number

Search Result 362, Processing Time 0.025 seconds

Studies on the Phase Separation of the Borosilicate Glass by Addition of Titanium Dioxide ($TiO_2$ 첨가에 따른 붕규산 유리의 분상에 관한 연구)

  • 박용완;민병욱
    • Journal of the Korean Ceramic Society
    • /
    • v.18 no.4
    • /
    • pp.257-261
    • /
    • 1981
  • The tendency of glass containing titanium-dioxide to separate into two phases can be attributed to a change of the coordination number of titanium from six to four on increase of temperature and to "freezing" of the high temperature four fold coordination on cooling of the melt. Addition of TiO2 to the basic glass 8.7 $Na_2O$ 22.4B2O3 68.9 $SiO_2$ was varied 5 to 25 parts. The phase separation in the temperature range of transformation was examined with each heating temperature and soaking time. As the experimental results, the most distinct phase separation were obtained from alkali extraction method when $TiO_2$ was added 15 parts. The apparant activation energy was 30.5 Kcal/mole by alkali extraction method derived from Arrhenius plots.ius plots.

  • PDF

A Study of Propriety Capacity about Protection Scheme When Distribution System Interconnected with Distributed Resources (배전계통에 분산전원 연계시 보호협조측면에서 적정용량 검토)

  • Lee Yeon-Hwa;Choi Joon-Ho;Jung Hyun-Jun;Nam Hae-Kon;Moon Chae-Joo;Park Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.520-522
    • /
    • 2006
  • According to the second scheme of the Korean Government about technology development, utilization and popularization of new renewable energy, the continuous growth of distributed resources are expected. But there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with position among protection devices. Adding distributed resource, the problems of each case are investigated through simulation.

  • PDF

Insulation coordination of 765 KV double circuit transmission line (765 KV 2 회선(回線) 송전선(送電線) 절연협조(絶緣協助))

  • Kim, Jeong-Boo;Min, Suk-Won;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.774-777
    • /
    • 1988
  • This paper covers the insulation coordination of 765 KV transmission line in Korea Electric Power Corporation. The design for the lightning, switching surge, and contamination was conducted to increase the reliability of 765 KV line. The authors have used the result of a limited Westinghouse ANACOM swiching surge study of the Korea Electric Corporation's 765 KV Expansion plan. The study investigated the switching surge overvoltage distribution and maximum switching overvoltage when relosing 765 KV lines. They used the technical data of the suspension insulator for the contamination design, which was available from a foreign insulator manufacture. From this paper, the authors find out that the contamination design dominates to determine the number of insulator and the SOV design dominates the air clearance in the tower. Afterwards the authors will confirm this design by Demonstration Test with Korea Electro-technology Research Institute.

  • PDF

A New IEEE 802.11 DCF Utilizing Freezing Experiences in Backoff Interval and Its Saturation Throughput

  • Sakakibara, Katsumi;Taketsugu, Jumpei
    • Journal of Communications and Networks
    • /
    • v.12 no.1
    • /
    • pp.43-51
    • /
    • 2010
  • IEEE 802.11 defines distributed coordination function (DCF), which is characterized by CSMA/CA and binary exponential backoff (BEB) algorithm. Most modifications on DCF so far have focused on updating of the contention window (CW) size depending on the outcome of own frame transmission without considering freezing periods experienced in the backoff interval. We propose two simple but novel schemes which effectively utilize the number of freezing periods sensed during the current backoff interval. The proposed schemes can be applied to DCF and its family, such as double increment double decrement (DIDD). Saturation throughput of the proposed schemes is analyzed by means of Bianchi's Markovian model. Computer simulation validates the accuracy of the analysis. Numerical results based on IEEE 802.11b show that up to about 20% improvement of saturation throughput can be achieved by combining the proposed scheme with conventional schemes when applied to the basic access procedure.

Molecular Dynamic Simulations of the Phase Transition of $\alpha-quartz$ and $\alpha-quartz-type$-type $GeO_2$ under High Pressure (고압력하에서의 $\alpha-quartz$$\alpha-quartz$$GeO_2$의 상전이에 관한 분자동력학시뮬레이션)

  • ;;;;河村雄;Zenbe-e Nakagawa
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.7
    • /
    • pp.713-721
    • /
    • 1997
  • Molecular dynamic (MD) simulations with new interatomic potential function including the covalent bond were performed on the phase transition of $\alpha$-quartz-type GeO2 under high pressure. The optimized crystal structure and the pressure dependence of the lattice constant showed higher reproducibility than the previous models and were in very good agreement with the experimental data. A phase transition of $\alpha$-quartz and $\alpha$-quartz-type GeO2 by simulation was found approximately 24 GPa and 6-7 GPa, respectively. This phase transition involved an abrupt volume shrinkage and showed 4-6 coordination mixed structure with the increasing in the coordination number of cation.

  • PDF

A Study on the Advanced Protective Coordination Schemes of Distribution System Considering Distributed Generations (분산전원을 고려한 배전계통의 개선된 보호협조 방안 연구)

  • Choi, Dong-Man;Choi, Joon-Ho;Moon, Seung-Il;Kim, Jae-Chul;Moon, Chae-Joo;Kim, Il-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.701-703
    • /
    • 2005
  • Recently, There has been growing interest in Distributed Generations with high-energy efficiency due to the Increasing energy consumption and environmental pollution problems. but an insertion of Distributed Generations to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to Sukumar M[l] proposal schemes and identity the faulted section performing short-circuit analysis by MATLAB program to distribution systems interconnected a large number of distributed generations.

  • PDF

The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line (지중배전선로의 다회로차단기 운영방안 연구)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.4
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

Correlation analysis of finger movements in dynamic hand grasping (잡기 동작에서 손가락 동작의 상관관계 분석)

  • Ryu, Tae-Beom;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.11-25
    • /
    • 2001
  • AS human movements have the inherent property of anticipating target and can be coordinated to realize a given schedule, finger movements have stereotyped patterns during hand grasping. Finger movements have been studied in the past to find out the coordination pattern of hand joint angular movement. These studies analyzed only a few finger joints for a limited number of hand postures. This study investigated fourteen joint angles during eight hand-grasping motions to analyze the angular correlations between finger joints and to suggest motion factors which represent hand grasping. Hand grasping motions including forward arm motion were examined in ten healthy volunteers. Eight objects were used to represent real hand grasping tasks. $CyberGlove^{TM}$ and $Fasreack^{TM}$ measured hand joint angles and wrist origin. Joint angle correlations between PIJ(proximal interphalangeal joint) and MPJ(metacarpophalangeal joint) at one finger, between neighboring PIJs and MPJs were four factors related to the fast phase of hand grasping motions and eight factors related to the slow phase of hand grasping motions.

  • PDF

Synthesis and Characterization of Group 13 Compounds of 2-Acetylpyridine Thiosemicarbazone. Single-Crystal Structure of $(iC_4H_9)-2Al(NC_5H_4C(CH_3)$NNC(S)NHPh)

  • 강영진;강상옥;고재정;손정인
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.1
    • /
    • pp.65-68
    • /
    • 1999
  • Novel mononuclear group 13 metal complexes with the formula (R2M){NC5H4C(CH3)NNC(S)NH(C6H5)} (M=Al, R=iC4H9 (1); M=Ga, R=iC4H9 (2); M=Al, R=CH2SiMe3 (3); M=Ga, R=CH2SiMe3 (4)) result when 2-acetyl pyridine 4-phenyl-thiosemicarbazone ligand is mixed with trialkyl aluminum or trialkylgallium. These compounds 1-4 are characterized by microanalysis, NMR (1H, 13C) spectroscopy, mass spectra, and singlecrystal X-ray diffraction. X-ray single-crystal diffraction analysis reveals that 1 is mononuclear metal compound with coordination number of 5 and N, N, S-coordination mode.