• Title/Summary/Keyword: Coordinate Control

Search Result 748, Processing Time 0.026 seconds

Correction of Geometric Distortion of Internet Aerial Imagery and Photo-Realistic 3D Building Modeling (인터넷 항공영상의 왜곡보정과 실감적 3차원 건물 모델링)

  • Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.6
    • /
    • pp.687-695
    • /
    • 2011
  • Many internet portals provide maps with spatial information services. Recently, various images including aerial, satellite, street view, and photo-realistic 3D city models are provided as well as maps. This study suggested a method for geometric correction of the panoramic aerial images in the internet portal and 3D building modeling using information which is available in the internet. The key of this study is to obtain all necessary data easily from internet without restrictions. Practically, the ground control coordinates could be available from geo-referenced internet maps, and stereo pairs of the aerial images and close-range photographs for photo-realistic object modeling are provided by the internet service. However, the ground control points are not suitable for accurate mapping. RMSE of the plotting was about 9 meters and reduced upto 4 meters after coordinate transformation. The proposed methods would be applicable to various applications of photo-realistic object modeling which do not require high accuracy.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

QUANTITATIVE DATA TO SHOW EFFECTS OF GEOMETRIC ERRORS AND DOSE GRADIENTS ON DOSE DIFFERENCE FOR IMRT DOSE QUALITY ASSURANCE MEASUREMENTS

  • Park, So-Yeon;Park, Jong-Min;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.183-189
    • /
    • 2011
  • To quantitatively evaluate how setup errors in conjunction with dose gradients contribute to the error in IMRT dose quality assurance (DQA) measurements. The control group consisted of 5 DQA plans of which all individual field dose differences were less than ${\pm}5%$. On the contrary, the examination group was composed of 16 DQA plans where any individual field dose difference was larger than ${\pm}10%$ even though their total dose differences were less than ${\pm}5%$. The difference in 3D dose gradients between the two groups was estimated in a cube of $6{\times}6{\times}6\;mm^3$ centered at the verification point. Under the assumption that setup errors existed during the DQA measurements of the examination group, a three dimensional offset point inside the cube was sought out, where the individual field dose difference was minimized. The average dose gradients of the control group along the x, y, and z axes were 0.21, 0.20, and 0.15 $cGy{\cdot}mm^{-1}$, respectively, while those of the examination group were 0.64, 0.48, and 0.28 $cGy{\cdot}mm^{-1}$, respectively. All 16 plans of the examination group had their own 3D offset points in the cube. The individual field dose differences recalculated at the offset points were mostly diminished and thus the average values of total and individual field dose differences were reduced from 3.1% to 2.2% and 15.4% to 2.2%, respectively. The offset distribution turned out to be random in the 3D coordinate. This study provided the quantitative data that support the large individual field dose difference mainly stems from possible geometric errors (e.g., random setup errors) under the influence of steep dose gradients of IMRT field.

HK Curvature Descriptor-Based Surface Registration Method Between 3D Measurement Data and CT Data for Patient-to-CT Coordinate Matching of Image-Guided Surgery (영상 유도 수술의 환자 및 CT 데이터 좌표계 정렬을 위한 HK 곡률 기술자 기반 표면 정합 방법)

  • Kwon, Ki-Hoon;Lee, Seung-Hyun;Kim, Min Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • In image guided surgery, a patient registration process is a critical process for the successful operation, which is required to use pre-operative images such as CT and MRI during operation. Though several patient registration methods have been studied, we concentrate on one method that utilizes 3D surface measurement data in this paper. First, a hand-held 3D surface measurement device measures the surface of the patient, and secondly this data is matched with CT or MRI data using optimization algorithms. However, generally used ICP algorithm is very slow without a proper initial location and also suffers from local minimum problem. Usually, this problem is solved by manually providing the proper initial location before performing ICP. But, it has a disadvantage that an experience user has to perform the method and also takes a long time. In this paper, we propose a method that can accurately find the proper initial location automatically. The proposed method finds the proper initial location for ICP by converting 3D data to 2D curvature images and performing image matching. Curvature features are robust to the rotation, translation, and even some deformation. Also, the proposed method is faster than traditional methods because it performs 2D image matching instead of 3D point cloud matching.

Offsite Consequence Analysis and safety management system process integration plan of safety management system (장외영향평가 및 공정안전관리제도의 통합 안전환경관리방안에 관한 연구)

  • Kim, Dong-Jun;Lee, In-Bok;Moon, Jin-Young;Chun, Young-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.63-70
    • /
    • 2016
  • The main point of this study is to find out duplicates and differences among various regulations from different organizations. Also, it focuses on creating a reasonably unified regulation system to standardize safety & environment management. In this study, I analyzed the commonalities and the differences of two systems which are typical korean Process Safety Management System and off-site Consequence Analysis. It is confirmed that there are 25 species of overlapped material of those two systems and assessment like handling material information, facilities lists, hazardous substances and list of machine power. Process safety report focuses on onsite workers and facility protect. On the other hand, off-site Consequence Analysis focuses on design, arrangement and management of handling facility from off-site influence. I found difference two system of Enforcement purposes and way. Contradiction of Harmful information of Chemicals Control Act and occupation safety and health acts from same material. To be specific, There are no unit rule of occupation safety and health acts. so it permit inch, psi etc. But Chemicals Control Act provides that m, Mpa units. Therefore, Each regulatory duplication of items for chemicals management, standardization is writing so that you can coordinate overlapping items in the measures the need to be presented.

A Study on the Fault Analysis for a Micro Smart Grid Simulator Design Using MEMS' Miniaturization Technology (MEMS의 소형화 기술을 이용한 마이크로 스마트 그리드 시뮬레이터 설계를 위한 고장해석법에 대한 연구)

  • Ko, Yun-Seok;Oh, Se-Pil;Kim, Hyo-Seong;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.315-324
    • /
    • 2017
  • The smart grid with distributed power supply introduces a number of problems including not only the problems of the existing power grid but also the problem of protection co-operation due to new electric phenomenon because it has a mixed operation structure combining the existing radial operation structure and the new loop operation structure. The EMTP based power system analysis method has flexibility and convenience from the view of system configuration but it requires another experimental verification because of uncertainty of design and analysis results. On the other hand, the real demonstration system has difficulties in observing accurate fault on large scale system due to considerable economical and spatial construction cost, system configuration constraint, and it is difficult to demonstrate the distributed, autonomous and adaptive control strategy of smart grid. In this paper, a basic theory for a micro smart grid simulator design using MEMS(Micro Electro-Mechanical Systems) miniaturization technology is studied which can safely and freely experiment and observe electrical phenomena, and distribution, autonomous adaptive control strategy for disturbances on 22.9kV smart grid under minimum economic and spatial cost.

Performance validation and application of a mixed force-displacement loading strategy for bi-directional hybrid simulation

  • Wang, Zhen;Tan, Qiyang;Shi, Pengfei;Yang, Ge;Zhu, Siyu;Xu, Guoshan;Wu, Bin;Sun, Jianyun
    • Smart Structures and Systems
    • /
    • v.26 no.3
    • /
    • pp.373-390
    • /
    • 2020
  • Hybrid simulation (HS) is a versatile tool for structural performance evaluation under dynamic loads. Although real structural responses are often multiple-directional owing to an eccentric mass/stiffness of the structure and/or excitations not along structural major axes, few HS in this field takes into account structural responses in multiple directions. Multi-directional loading is more challenging than uni-directional loading as there is a nonlinear transformation between actuator and specimen coordinate systems, increasing the difficulty of suppressing loading error. Moreover, redundant actuators may exist in multi-directional hybrid simulations of large-scale structures, which requires the loading strategy to contain ineffective loading of multiple actuators. To address these issues, lately a new strategy was conceived for accurate reproduction of desired displacements in bi-directional hybrid simulations (BHS), which is characterized in two features, i.e., iterative displacement command updating based on the Jacobian matrix considering nonlinear geometric relationships, and force-based control for compensating ineffective forces of redundant actuators. This paper performs performance validation and application of this new mixed loading strategy. In particular, virtual BHS considering linear and nonlinear specimen models, and the diversity of actuator properties were carried out. A validation test was implemented with a steel frame specimen. A real application of this strategy to BHS on a full-scale 2-story frame specimen was performed. Studies showed that this strategy exhibited excellent tracking performance for the measured displacements of the control point and remarkable compensation for ineffective forces of the redundant actuator. This strategy was demonstrated to be capable of accurately and effectively reproducing the desired displacements in large-scale BHS.

Underwater E-plane Attenuation Model of Omnidirectional Antenna Using Half Power Beam Width (HPBW) (반전력빔폭을 이용한 전방향성 안테나의 수중 환경 수직 평면 감쇠 모델)

  • Kwak, Kyungmin;Park, Daegil;Kim, Younghyeon;Chung, Wan Kyun;Kim, Jinhyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1050-1056
    • /
    • 2015
  • In this paper, we use the characteristics of electromagnetic waves underwater attenuation for estimating linear distance between a transmitting node and receiving node, and research underwater vertical plane attenuation model for constructing the underwater localization system. The underwater localization of 2 dimensional with the plane attenuation model in the horizontal plane (H-plane) was proposed previous research. But for the 3 dimensional underwater localization, the additional vertical plane (E-plane) model should be considered. Because the horizontal plane of omnidirectional antenna has the same attenuation tendency in x-y plane according to the distance, whereas in vertical plane shows an irregular pattern in x-z plane. For that reason, in the vertical plane environment, the attenuation should be changed by the position and inclination. Hence, in this paper the distance and angle between transmitting and receiving node are defined using spherical coordinate system and derive an antenna gain pattern using half power beam width (HPBW). The HPBW is called a term which defines antenna's performance between isotropic and other antennas. This paper derives omnidirectional antenna's maximum gain and attenuation pattern model and define vertical plane's gain pattern model using HPBW. Finally, experimental verifications for the proposed underwater vertical plane's attenuation model was executed.

Effects of Differential Stability on Control of Multi-Joint Coordination in the Upper Extremity: A Torque Component Analysis

  • Ryu, Young Uk;Shin, Hwa Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The purpose of the present current study was to examine control of upper limb multi-joint movements with differential coordination stability. To achieve the goals of the study, torque analyses were utilized to answer questions about how torque components were differed among various elbow-wrist coordination patterns. Methods: Eight self-reported right-handed college students (3 males and 5 females, mean age=20.6 yr) were volunteered. The task required participants to rhythmically coordinate the flexion-extension motions of their elbow and wrist with coordination relationship of $0^{\circ}$, $90^{\circ}$, and $180^{\circ}$relative phases between the two joints. Mean relative phase and phase stability (standard deviation of relative phase) were computed to for analysisze of overall coordination performance. To determine the figure out characteristics of torque components in elbow and wrist joints, impulse values of muscle torque (MT) and interactive torque (IT) and MT as a percentage of cycle duration (MT-PCD) were analyzed. Results: Torque results showed that the proximal elbow joint generated motions with mainly muscle efforts regardless of coordination patterns, while the distal wrist joint adjusted the coordination patterns by changing amount of MT. Impulse analyses showed that the least stable $90^{\circ}$ pattern was performed by utilizing a similar coordination strategy of the most stable $0^{\circ}$ pattern. Conclusion: The present current study suggests that the roles of distal and proximal joints differ in order to achieve various multi-joint coordination movements. This study provides information for use in gives an idea to development of rehabilitation or training programs for to persons with an impaired upper limb motor ability.

GIGANTEA Regulates the Timing Stabilization of CONSTANS by Altering the Interaction between FKF1 and ZEITLUPE

  • Hwang, Dae Yeon;Park, Sangkyu;Lee, Sungbeom;Lee, Seung Sik;Imaizumi, Takato;Song, Young Hun
    • Molecules and Cells
    • /
    • v.42 no.10
    • /
    • pp.693-701
    • /
    • 2019
  • Plants monitor changes in day length to coordinate their flowering time with appropriate seasons. In Arabidopsis, the diel and seasonal regulation of CONSTANS (CO) protein stability is crucial for the induction of FLOWERING LOCUS T (FT) gene in long days. FLAVIN-BINDING, KELCH REPEAT, F-BOX 1 (FKF1) and ZEITLUPE (ZTL) proteins control the shape of CO expression profile antagonistically, although regulation mechanisms remain unknown. In this study, we show that GIGANTEA (GI) protein modulates the stability and nuclear function of FKF1, which is closely related to the stabilization of CO in the afternoon of long days. The abundance of FKF1 protein is decreased by the gi mutation, but increased by GI overexpression throughout the day. Unlike the previous report, the translocation of FKF1 to the nucleus was not prevented by ZTL overexpression. In addition, the FKF1-ZTL complex formation is higher in the nucleus than in the cytosol. GI interacts with ZTL in the nucleus, implicating the attenuation of ZTL activity by the GI binding and, in turn, the sequestration of FKF1 from ZTL in the nucleus. We also found that the CO-ZTL complex presents in the nucleus, and CO protein abundance is largely reduced in the afternoon by ZTL overexpression, indicating that ZTL promotes CO degradation by capturing FKF1 in the nucleus under these conditions. Collectively, our findings suggest that GI plays a pivotal role in CO stability for the precise control of flowering by coordinating balanced functional properties of FKF1 and ZTL.