• Title/Summary/Keyword: Cooling loss

Search Result 573, Processing Time 0.028 seconds

Improving Fuel Efficiency of a Hybrid Excavator (하이브리드 굴삭기 연비 개선 연구)

  • Cho, Sungwoo;Yoo, Seungjin;Park, Cheol-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.211-217
    • /
    • 2015
  • Emission gas regulations and constantly increasing fuel costs call for the worldwide use of environmentally friendly and energy-efficient machines in industry. To meet these requirements, a hybrid excavator prototype has been developed that incorporates an electric swing motor, engine assist motor, and ultra-capacitor module into a conventional hydraulic excavator of the 22-ton class. This paper mainly describes a few techniques to optimize its energy efficiency. These include 1) controlling the engine speed in proportion to the load torque, 2) controlling the pump displacement when driving the electric swing system, 3) managing the ultra-capacitor voltage to minimize the electrical energy loss, and 4) reducing the cooling fan speed to improve the energy efficiency of the system.

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF

Population Structure of Surface Swarms of the Euphausiid Euphausia pacifica Caught by Drum Screens of Uljin Nuclear Power Plant in the East Coast of Korea

  • Suh, Hae-Lip;Lim, Ju-Hwan;Soh, Ho-Young
    • Journal of the korean society of oceanography
    • /
    • v.33 no.1-2
    • /
    • pp.35-40
    • /
    • 1998
  • In February and April 1997, three temporary interruptions of electric power production at the Uljin Nuclear Power Plant in the east coast of Korea were caused by the malfunction of the cool-ing-water supply unit. The clogging of the drum screens inside the unit caused by the surface swarm of the euphausiid Euphausia pacifica Hansen might be responsible for the malfunction. These incidents were of particular interest since such interruption of reactors' operation by krill swarms had not previously been reported. Using samples caught by the drum screens inside the cooling water-supply unit, we investigated the population structure of surface swarms. One occasion of nighttime and three occasions of daytime surface swarms were found in February and April 1997, respectively. The foreguts of more than 60% of E. pacifica in nighttime surface swarm were in full condition. This evidence suggests that E. pacifica aggregates to the surface water at night for feeding. In daytime surface swarms consisting of mature E. pacifica, however, foreguts in full condition were only found in less than 10eio of krill examined, suggesting that daytime surface swarms are closely related to breeding activity. During the study period, the growth rate of mature females was more than twice higher than that of mature males. Analyses of the sex-ratio and length-frequency data show a decrease in the portion of males with increasing size. There was a decline in the number of males of 19 mm in length. Energy loss during spermatophore transfer may result in the death of male E. pacifica, as found in male E. superba.

  • PDF

A Study on Characteristic of High Frequency Induction Heating for Local Heating (국부가열용 고주파 유도가열 특성에 관한 연구)

  • Jin, Hyung-Kook;Lee, Dong-Ju;Shin, Sang-Beom
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.60-60
    • /
    • 2010
  • Since the curved hull plate was made by a series of manufacturing process including cold bending, manual local heating and correction work, the accuracy of curved plate strongly depends on the proficiency of worker. So the demands on the automatic local heating system for curved hull plate have continuously increased and the various researches relevant to it have been performed. Generally, the heat sources used for local heating were flame and induction heat. In terms of initial cost, flame heating is in a better favorable position than induction heating. However, from the viewpoint of the control of heat, induction heating has more advantage. So the various researches related to apply the induction heating to the automatic forming system has been performed. The purpose of this study is to establish the proper capacity of high frequency induction heating system for forming the curved hull plate. In order to do it, the proper coil shape for local heating was designed and the efficiency of induction heating system was determined by comparing of temperature results obtained by FEA and experiment. With the results, the extensive FEA was performed to identify the effect of heated plate dimension, cooling method and the capacity of induction heating system on the amount of heat loss introduced by induction heating. Based on the results, the proper capacity of high frequency induction heating system was proposed.

  • PDF

A Dual Integer Register File Structure for Temperature - Aware Microprocessors (온도 인지 마이크로프로세서를 위한 듀얼 레지스터 파일 구조)

  • Choi, Jin-Hang;Kong, Joon-Ho;Chung, Eui-Young;Chung, Sung-Woo
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.12
    • /
    • pp.540-551
    • /
    • 2008
  • Today's microprocessor designs are not free from temperature as well as power consumption. As processor technology scales down, an on-chip circuitry increases power density, which incurs excessive temperature (hotspot) problem. To tackle thermal problems cost-effectively, Dynamic Thermal Management (DTM) has been suggested: DTM techniques have benefits of thermal reliability and cooling cost. However, they require trade-off between thermal control and performance loss. This paper proposes a dual integer register file structure to minimize the performance degradation due to DTM invocations. In on-chip thermal control, the most important functional unit is an integer register file. It is the hotspot unit because of frequent read and write data accesses. The proposed dual integer register file migrates read data accesses by adding an extra register file, thus reduces per-unit dynamic power dissipation. As a result, the proposed structure completely eliminates localized hotspots in the integer register file, resulting in much less performance degradation by average 13.35% (maximum 18%) improvement compared to the conventional DTM architecture.

Turbulent Heat Transfer and Friction in Four-Wall Convergent/Divergent Square Channels with One Ribbed Wall (한면에 리브가 설치된 4벽면 수축/확대 채널의 난류 열전달과 유체마찰)

  • Ahn, Soo Whan;Lee, Myung Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.773-778
    • /
    • 2015
  • The local heat transfer and pressure drop of developed turbulent flows in convergent/divergent channels with square axial cross-sectional areas were experimentally investigated to improve the channel design, such as a gas turbine cooling system. Square convergent/divergent channels with one ribbed wall were manufactured with a fixed rib height e of 10 mm and a ratio of rib spacing p to height e of 10. The measurement was conducted for Reynolds numbers from 15,000 to 89,000. Convergent, divergent, and straight channels with ratios $D_{ho}/D_{hi}$ of 0.75, 1.33, and 1.0, respectively, are considered. Of the three channel types, the ribbed divergent channel was found to produce the best thermal performance under identical flow rate, pumping power, and pressure loss conditions.

Calculation of Night Sky Temperature According to Cloudiness in Daegu (운량에 따른 대구지방의 야간 천공온도 산정)

  • Na, Wook-Ho;Lee, Jong-Won;Diop, Souleymane;Lee, Hyun-Woo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • To estimate the radiative heat loss from greenhouses, a new equation for calculating the sky temperature is presented. The sky temperature in the Daegu region was measured using a pyrgeometer and calculated using different equations according to the cloudiness. The calculated and measured results were then compared to identify the best equation for calculating the sky temperature. The difference value between the air and sky temperature was dissimilar and increased as the cloud amount decreased. On clear days the difference value was 10~20 times greater than that on cloudy and rainy days. When analyzing the correlationship between the calculated and measured sky temperatures on clear days, Bliss's and Clark & Allen's equations were found to be superior to the other equations. However, on cloudy days, the best correlationship between the calculated and measured sky temperatures was exhibited by Fuentes's equation. Therefore, a new equation is proposed for calculating the sky temperature on a cloudy day.

  • PDF

Thermal Environment Characteristic of the Heat Storage Gypsum Board Included with Phase Change Material (PCM 함유된 축열석고보드의 열환경특성)

  • Kwon, Oh-Hoon;Yun, Huy-Kwan;Han, Seong-Kuk;Ahn, Dae-Hyun;Shim, Myeong-Jin;Cho, Sung-Woon;Park, Jong-Soon;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.570-574
    • /
    • 2010
  • The main function of conventional insulation materials is only to block the heat transfer and reduce heat loss from the building. On the other hand, thermal storage materials can work as an energy saver by absorbing or emitting heat within a specific temperature range. Thermal storage materials for building can maintain a constant temperature by effectively regulating the cycle of indoor temperature. As a result, we can enhance the performance of a cooling and heating system efficiently. In this study, phase change materials (PCMs) were added as thermal storage materials into gypsum boards which are extensively used for building material and we found out the thermal environmental characteristics. In addition, we checked out some problems when applying the thermal storage materials to buildings. Finally, This study set out to examine the degree of environmental-friendly characteristics of thermal storage building materials by analyzing the amount of TVOC and HCHO contents with the possibility of pollutants emission.

1-D Analysis of Tandem-ejector for the Engine-bay Ventilation (엔진베이 환기용 탠덤 이젝터의 1차원 해석모델링 기법 개발)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon;Jun, Sang In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.4
    • /
    • pp.81-89
    • /
    • 2014
  • Tandem-ejector has been devised for engine-bay cooling. In this study, 1-D model has been developed to analyze Tandem-ejector. In the model, the primary, the secondary and the tertiary flow conditions have been analyzed with isentropic process. The mixing process has been analyzed with conservation laws based on the control volume analysis. The total pressure loss of the primary flow has been analyzed under the matching condition between the static pressure of Tandem-ejector discharge flow and atmospheric pressure. Consequently, 1-D model can predict Tandem-ejector performance accurately and provide the performance map.

Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor (오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.