• 제목/요약/키워드: Cooling frame

검색결과 71건 처리시간 0.029초

하이브리드 자동차용 엔진 내부의 전자식 수온조절기의 감온성 및 유량제어 정확도 향상을 위한 수치 및 실험적 연구 (Numerical and Experimental Study to Improve Thermal Sensitivity and Flow Control Accuracy of Electronic Thermostat in the Engine for Hybrid Vehicle)

  • 정수진;정진우;하승찬
    • 한국분무공학회지
    • /
    • 제26권3호
    • /
    • pp.135-141
    • /
    • 2021
  • High-efficient HEV Engine cooling systems reflects variable coolant temperature because it can decrease the hydrodynamic frictional losses of lubricated engine parts in light duty conditions. In order to safely raise the operating temperature of passenger cars to a constant higher level, and thus optimize combustion and all accompanying factors, a new thermostat technology was developed : the electronically map-controlled thermostat. In this work, various crystalline plastics such as polyphthalamide (PPA) and polyphenylenesulfide (PPS) mixed with various glass fiber amounts were introduced into plastic fittings of automotive electronic controlled thermostat for the purpose of suppressing influx of coolant into the element and undesirable opening during hot soaking. Skirt was installed around element frame of automotive electronic controlled thermostat for improving thermal sensitivity in terms of response time, hysteresis and melting temperature. To validate the effectiveness and optimum shape of skirt, thermal sensitivity test and three-dimensional CFD simulation have been performed. As a consequence, important improvement in thermal sensitivity with less than 3℃ of maximum coolant temperature between opening and engine inlet was obtained.

밀폐 공간에서 용접작업을 위한 단열 복합재 프레임의 설계 적용 연구 (A Study on the Application of Thermal Insulation Composite Frame for Welding in Enclosed Space)

  • 이재열;전광우;홍성호;신광복
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.227-237
    • /
    • 2018
  • 본 논문에서는 밀폐/협소의 공간에 적용을 위한 이동형 용접 로봇의 매니퓰레이터의 경량화 및 단열 성능 확보를 위한 설계 적용 연구 내용을 나타내었다. 선박 및 해양플랜트와 같이 구조가 복합하고 협소한 공간에 대한 용접 작업을 위하여 용접사를 작업 대상물 외부에서 용접로봇을 이용한 용접작업을 위하여 다양한 로봇 플랫폼이 개발되고 있다. 일반적인 로봇의 개발 과정은 적용 환경과 요구조건을 고려하여 기계 개발, 전자 장치 개발, 제어 알고리즘 개발 및 통합 검증으로 이루어 진다. 용접로봇의 완성도 높은 개발을 위하여 로봇 플랫폼의 기본 설계에서 환경 조건을 고려한 로봇 매니퓰레이터의 경량 설계를 수행하였다. 또한, 단열성능 및 냉각 성능 확보를 위한 소재 선정과 검증, 해석 및 시험의 과정을 거처 개발된 로봇과 연구 결과를 나타내었다.

매설지선 방식을 적용한 에너지 자립마을용 수상 태양광 발전 시스템의 접지저항 분석 (Analysis of Grounding Resistance for Zero Energy Town Floating PV System Using Underground Wiring)

  • 고재우;임종록;;차혜림;김시한;이창구;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.303-306
    • /
    • 2016
  • Floating PV system is installed on the water such as artificial lake, reservoir, river for the purposes of zero energy town and/or large scale of PV station. There are electrical gains from cooling effect by water and reflection of water surface. Particularly, floating PV power station with high efficiency solar cell modules receives a lot of attention recently. Floating PV system is installed on the water, which means grounding method to the frame of solar cell and electrical box such as connector band and distribution panelboard should be applied in different way from grounding method of PV system on land. The grounding resistance should be 10[${\Omega}$] in case the voltage is over 400[V] in accordance with Korean Standard. The applicable parameters are the resistivity of water in various circumstances, depth of water, and length of electrode in order to meet 10[${\Omega}$] of grounding resistance. We calculated appropriate length of the electrode on the basis of theoretical equation of grounding resistance and analyzed the relation between each parameters through MATLAB simulation. This paper explains grounding system of floating PV power station and presents considerations on grounding design according to the resistivity of water.

도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 - (Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles -)

  • 백성옥;박상곤
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

극후판 Box Column 코너이음부의 용접잔류응력 및 Groove형상 특성에 관한 연구 (A Study on the Characteristics of Welding Residual Stresses and Groove Sja[e pf Cprmer Joint in Box Column with Ultra Thick Plate)

  • 방한서;안규백;김종명;석한길;장웅성
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.97-103
    • /
    • 1999
  • Ships, structures on the ocean, bridges, and other structures tend to be large by the development of industry. These ultra thick plate were welded with large heat input, which causes welding stresses, deformation and buckling, so it has to be considered the weld design, safety, reliability. The welded residual stresses were produced and redistributed due to the effect of large heat input. The mechanical phenomenon has not been surely identified yet. In spite of the lack of the study on the box column, there are various types of steel frame such as I type, H type, + type and $\bigcirc$ type, used in high story building. In this study, we performed computer simulation with two dimensional heat conduction and plane deformation thermal elasto-plastic finite element computer program as changing the plate thickness to 100mm, 150mm and groove angle to $60^{\circ}C$, $45^{\circ}C$, $30^{\circ}C$ of corner joint in box column. And then, to identify mechanical phenomenon such as the phenomenon of thermal distribution, welding residual stresses and deformation and to decide optimum groove angle and welding condition. The main conclusion can be summarized as follows: 1) Since the groove angle has became cooling down rapidly due to its smaller value, the temperature slope was steeped somewhat. 2) The tensile stress within the welding direction stresses was somewhat decreased at the weld metal and HAZ, increasing of the groove angle. 3) The local stress concentration of the groove angle $60^{\circ}C$ was appeared smaller than groove angle $30^{\circ}$.

  • PDF

큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 - (Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area -)

  • 윤용철;서원명;유찬
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.217-225
    • /
    • 2004
  • 본 조사는 최근 급격히 증가하고 있는 새송이버섯 재배농가의 안정적 영농을 위해 재배사 설계, 시공 및 환경조절과 관련한 기초 자료를 마련하기 위해 서부 경남지역을 대상으로 새송이버섯 재배사의 재배사 규모, 환경조절시스템 등의 실태조사 및 검토를 하였다. 재배사의 형태는 반영구재배사와 영구재배사로 대별 할수 있었고, 반영구재배사는 대부분 단동이었고, 영구재배사의 경우는 단동에 비해 상대적으로 연동이 많았다. 그리고 재배사의 규모는 형태에 관계없이 다양하였지만, 길이, 폭 및 동고는 각각 20m, $6.6\~7.0m$$4.6\~5.0m$정도의 농가가 가장 많았으며, 동당 바닥면적은 $132\~140m^2$(40-42평)정도의 범위로서 대부분 콘크리트로 처리하여 각종 균에 의한 버섯의 오염을 방지 할 수 있도록 되어 있었다. 반영구 및 영구재배사의 지붕경사각은 각각 $41.5^{\circ}$$18.6\~28.6^{\circ}$로 나타나 반영구재배사의 지붕경사도가 더 큰 것으로 나타났다. 그리고 재배상의 폭 및 단수는 재배사의 형태에 관계없이 각각 $1.2\~1.6m$정도와 4단이 주류를 이루고 있었다. 버섯을 연중재배 하는 재배사에는 모두 냉${\cdot}$난방시설, 가습장치 및 환기팬이 설치되어 있었다. 난방방식의 경우, 온수보일러, 전기히터, 증기보일러 순으로 나타났다. 냉방장치의 경우는 모두 산업용 에어컨을 설치하여 운용하고 있었다. 그리고 가습은 초음파가습기와 원심분리가습기를 사용하고 있었으며, 보조 장치로 분무노즐을 사용하는 농가도 일부 있었다. 또한 온${\cdot}$습도 조절 및 탄산가스 조절을 위한 장치의 제어는 동별 제어시스템을 많이 채택하고 있었다. 그리고 온도센서 이외는 모두 타이머를 이용하고 있음을 알 수 있었다. 배지병의 크기는 850 cc 및 1,100 cc를 사용하는 농가가 주류를 이루고 있었고, 이 밖에도 800cc와 950 cc, 1,200 cc병을 사용하는 농가도 있었다. 출하형태는 대부분 유통회사와 공판장을 동시에 이용하고 있었다.

창호의 단열성능 간이 개선방법의 비교 분석 (A Comparative Evaluation on the Thermal Insulation Performance of Windows according to the Temporary Improvement Method)

  • 이성진;김정국;김종훈;정학근;이진숙;장철용
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.77-82
    • /
    • 2015
  • The purpose of this study is to compare the thermal insulation performance of windows according to the formation of air layer and to evaluate its energy efficiency on a selected standard house. A thermal insulation test, KS F 2278 was used to measure U-values (Heat transmission coefficients) for the following three cases: the first case (Case 1) is a Low-E pair glass (Argon injected), the second case (Case 2) is a Low-E pair glass with the air cap attached on the glass surface, and the third case (Case 3) is a Low-E pair glass, on the frame of which the air cap is attached. The evaluation of the energy efficiency was conducted according to a building energy calculation method from ISO 13790, calculation of energy use for space heating and cooling, using the U-values obtained from the thermal insulation tests. As results of the tests, the U-values of Case 1, Case 2, and Case 3 were $1.668W/m^2{\cdot}K$, $1.568W/m^2{\cdot}K$, and $1.319W/m^2{\cdot}K$ respectively. The Case 2 had about 5.9% lower value than the Case 1, and the Case 3 had about 20.9% lower value than the Case 1. It seems that the thermal performance of the windows is attributed to an increase of the heat resistance and the thickness of air layer. An evaluation of the energy efficiency of the three cases on the selected standard house showed that the amount of heating energy demand per unit area was $7.776kWh/m^2{\cdot}yr$ for the Case $1,6.856kWh/m^2{\cdot}yr$ for the Case 2, and $4.856kWh/m^2{\cdot}yr$ for the Case 3. This study suggests that the formation of air layer (by using air cap) and its thickness should reduce the heat energy demand and thus improve the energy saving efficiency

영구형 큰느타리버섯 재배사의 환경요인 분석 (Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure)

  • 윤용철;서원명;이인복
    • 생물환경조절학회지
    • /
    • 제15권2호
    • /
    • pp.125-137
    • /
    • 2006
  • 본 연구에서는 큰느타리버섯 재배사의 환경조절을 최적화하고 시스템 설계에 대한 기초자료를 얻기 위하여 진주인근에 위치한 샌드위치패널을 이용한 영구형 재배사 2동을 대상으로 2003년 11월부터 2005년 10월까지 재배사 내부에서 측정한 환경인자들을 중심으로 검토하였다. 실험지역의 외기온은 평년의 것과 대체로 비슷한 경향을 보였다. 시스템 변경전의 경우, 동절기에는 전체적으로 설정온도보다 낮게 유지되었고, 또 최상부와 최하부의 최대온도 편차도 $5.1^{\circ}C$ 정도로 상층이 가장 높게 나타났다. 그러나 시스템의 변경 후의 경우, 난방시 대체로 설정온도 범위에서 조절되는 경향을 보였고, 공기정체나 온도층의 역전현상이 나타나지 않았다. 상대습도는 시스템 변경 후, $80{\sim}100%$ 정도의 범위로서 권장상대습도 범위에 있었다. 전체 재배기간동안 탄산가스 농도는 $400{\sim}3,300mg{\cdot}L^{-1}$ 정도의 범위에 있었다. 조도는 권장조도보다 전반적으로 낮게 유지되고 있음을 알 수 있었고, 산도는 대체로 일정하게 유지되었다. 수확량은 전체적으로 일정하지 않았고, 포기재배의 경우가 상대적으로 등외품이 적었으며, 증수 효과도 있었다. 전력소비량은 계절별로 일정한 경향이 있음을 알 수 있었고, 하절기보다 동절기에 전력소비량이 현저히 많은 것을 확인 할 수 있었다.

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF