• Title/Summary/Keyword: Cooling effect

Search Result 2,341, Processing Time 0.038 seconds

A Study on the Effects of Droplets Characteristics of Water Mist on the Spray Density on the Floor (미분무 액적특성이 살수밀도에 미치는 영향 연구)

  • Kim, Jong-Hoon;Park, Won-Hee;Kim, Woon-Hyung;Myoung, Sang-Yup
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.120-127
    • /
    • 2021
  • Purpose: In this study, the effect of changes in the variables related to water droplets on the spray density on the floor in the analysis of the water mist fire protection system using FDS was analyzed. Method: When the spray of the water mist nozzle was analyzed in FDS, Particles Per Seconds, Particle Velocity, Size Distribution, and Spray Pattern Shape that can be set in relation to droplets were input to review the analyzed results. Result: In the analysis results, when the number of particles per second was set above a certain value, the spray density of the floor was similar. In the case of Particle Velocity, as the velocity decreases, the spray density of the central portion increases but decreases at a distance of 0.15m or more. From the analysis of the change in the size distribution function, it was found that an increase in the 𝛾 value increases the spray density of the central part, but the value at a remote location decreases. Compared to the result of applying the Gaussian distribution, the median value decreases dramatically when the uniform distribution is applied, but the value at the adjacent position increases. Conclusion: Variables related to the droplet properties of the FDS affect the spray density of the floor. Therefore, in order to increase the reliability of results before performing analyses such as fire suppression or cooling, a sufficient review of input variables is required.

Impact of Renewable Energy on Extension of Vaccine Cold-chain: a case study in Nepal (신재생 에너지의 백신 콜드체인 확장 효과: 네팔 사례 연구)

  • Kim, Min-Soo;Mun, Jeong-Wook;Yu, Jongha;Kim, Min-Sik;Bhandari, Binayak;Bak, Jeongeun;Bhattachan, Anuj;Mogasale, Vittal;Chu, Won-Shik;Lee, Caroline Sunyong;Song, Chulki;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Renewable energy (RE) is essential to comprise sustainable societies, especially, in rural villages of developing countries. Furthermore, application of off-grid RE systems to health care can improve the quality of life. In this research, a RE-based vaccination supply management system was constructed to enlarge the cold-chain in developing countries for the safe storage and delivery of vaccines. The system was comprised of the construction of RE plants and development of vaccine carriers. RE plants were constructed and connected to health posts in local villages. The cooling mechanism of vaccine carriers was improved and monitoring devices were installed. The effect of the system on vaccine cold-chain was evaluated from the field test and topographical analysis in the southern village of Nepal. RE plants were normally operated for the vaccine refrigerator in the health post. The modified vaccine carriers had a longer operation time and better temperature control via monitoring and RE-based recharging functionality. The topographical analysis estimated that the system can cover larger region. The system prototype showed great potential regarding the possibility of a sustainable and enlarged cold-chain. Thus, RE-based vaccine supply management is expected to facilitate vaccine availability while minimizing waste in the supply chain.

Oxalate Chelating Activity of Egg White Proteins and Their Hydrolysates

  • Holipitiyage Shyami Rashmiki, Holipitiya;Palihawadanege Iresha Lakmini, Fernando;Ethige Chathura Nishshanka, Rathnapala;Alakolange Gedara Achala Wimukthika, Alakolanga;Edirisinghe Dewage Nalaka Sandun, Abeyrathne;Ki-Chang, Nam
    • Korean Journal of Poultry Science
    • /
    • v.49 no.4
    • /
    • pp.221-228
    • /
    • 2022
  • Major egg white proteins and their hydrolysates serve as functional food ingredients that have certain metal-chelating properties. Employing egg white proteins and their hydrolysates to scavenge dietary oxalates is anticipated to have beneficial effect in the prevention of kidney stones. The objective of this study was to determine the biogenic oxalate-chelating activity of ovalbumin, ovomucin, and ovotransferrin and their hydrolysates. To prepare oxalate extracts, 30 mL of 0.25 N HCl was added to separately to 0.5 g of dried spinach and starfruit powders followed by boiling for 15 min, and after cooling, the addition of a further 20 mL of 0.25 N HCl. Having prepared these extracts, ovalbumin, ovomucin, and ovotransferrin and their hydrolysates were separately mixed with oxalate extracts and incubated at 3℃ for 24 h. Following centrifugation, supernatants were analyzed by HPLC using a reverse-phase C18 column coupled with a diode array detector. We found that all assessed proteins and their hydrolysates showed biogenic oxalate-chelating activity against the oxalates of spinach. In contrast, however, only ovalbumin, ovalbumin-hydrolysate, and ovomucin showed chelating activity (57.10%±8.84%, 85.44%±5.30%, 73.20%±4.13%, respectively) against the oxalates of starfruit (P<0.05). Overall, hydrolyzed ovalbumin was identified as the most effective chelator of the oxalates both spinach and starfruit. In this study, we thus established that the assessed egg white proteins and their hydrolysates have oxalate-chelating activity in vitro, thereby indicating that these compounds have potential utility as nutraceuticals for the chelation of dietary oxalate. However, further research will be necessary to verify their oxalate-chelating activities against different fruits and vegetables and under specific in vivo conditions and against purified oxalate.

Effect of Deposition and Heat Treatment Conditions on the Electrical and Optical Properties of AZO/Cu/AZO Thin Film (증착 및 열처리 조건에 따른 AZO/Cu/AZO 박막의 전기적·광학적 특성 평가)

  • Chan-Young Kim;Ha-Eun Lim;Gaeun Yang;Sukjeang Kwon;Chan-Hee Kang;Sang-Chul Lim;Taek Yeong Lee
    • Korean Journal of Materials Research
    • /
    • v.33 no.4
    • /
    • pp.142-150
    • /
    • 2023
  • AZO/Cu/AZO thin films were deposited on glass by RF magnetron sputtering. The specimens showed the preferred orientation of (0002) AZO and (111) Cu. The Cu crystal sizes increased from about 3.7 nm to about 8.5 nm with increasing Cu thickness, and from about 6.3 nm to about 9.5 nm with increasing heat treatment temperatures. The sizes of AZO crystals were almost independent of the Cu thickness, and increased slightly with heat treatment temperature. The residual stress of AZO after heat treatment also increased compressively from -4.6 GPa to -5.6 GPa with increasing heat treatment temperature. The increase in crystal size resulted from grain growth, and the increase in stress resulted from the decrease in defects that accompanied grain growth, and the thermal stress during cooling from heat treatment temperature to room temperature. From the PL spectra, the decrease in defects during heat treatment resulted in the increased intensity. The electrical resistivities of the 4 nm Cu film were 5.9×10-4 Ω·cm and about 1.0×10-4 Ω·cm for thicker Cu films. The resistivity decreased as the temperature of heat treatment increased. As the Cu thickness increased, an increase in carrier concentration resulted, as the fraction of AZO/Cu/AZO metal film increased. And the increase in carrier concentration with increasing heat treatment temperature might result from the diffusion of Cu ions into AZO. Transmittance decreased with increasing Cu thicknesses, and reached a maximum near the 500 nm wavelength after being heat treated at 200 ℃.

An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel (도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoon, Chan-Hoon;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • An experimental study was carried out on a reduced scale model tunnel to investigate the efficiency of disaster prevention at underground and ground ventilation equipments for the fire in road tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was manufactured. The vertical shafts that are used in the analysis of efficiency of disaster prevention are the two models that had considered when the real tunnels are designed and the amounts of smoke exhaust are applied the miniature of the real tunnels' smoke exhaust, 560 and $280\;m^3/s$. As the result of analysis, it is the possible the emissions of the entire quantity of CO gas through the vertical shafts. In the ground ventilation equipments, the concentration of CO is discharged 2.23~2,73 ppm smaller than the underground ventilation equipments. And the temperature rise in the ground ventilation equipments is $0.53{\sim}0.94^{\circ}C$ lower than in the underground ventilation equipments because of a cooling effect of the surface of the tunnel wall. As a result of analysis of CO concentration and the temperature rise in the modeling ventilation equipment, the position of ground ventilation equipment is more effective than the underground ventilation equipment in disaster prevention measures.

Computational Fluid Dynamics Study of Channel Geometric Effect for Fischer-Tropsch Microchannel Reactor (전산유체역학을 이용한 Fischer-Tropsch 마이크로채널 반응기의 채널 구조 영향 분석)

  • Na, Jonggeol;Jung, Ikhwan;Kshetrimayum, Krishnadash S.;Park, Seongho;Park, Chansaem;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.826-833
    • /
    • 2014
  • Driven by both environmental and economic reasons, the development of small to medium scale GTL(gas-to-liquid) process for offshore applications and for utilizing other stranded or associated gas has recently been studied increasingly. Microchannel GTL reactors have been prefrered over the conventional GTL reactors for such applications, due to its compactness, and additional advantages of small heat and mass transfer distance desired for high heat transfer performance and reactor conversion. In this work, multi-microchannel reactor was simulated by using commercial CFD code, ANSYS FLUENT, to study the geometric effect of the microchannels on the heat transfer phenomena. A heat generation curve was first calculated by modeling a Fischer-Tropsch reaction in a single-microchannel reactor model using Matlab-ASPEN integration platform. The calculated heat generation curve was implemented to the CFD model. Four design variables based on the microchannel geometry namely coolant channel width, coolant channel height, coolant channel to process channel distance, and coolant channel to coolant channel distance, were selected for calculating three dependent variables namely, heat flux, maximum temperature of coolant channel, and maximum temperature of process channel. The simulation results were visualized to understand the effects of the design variables on the dependent variables. Heat flux and maximum temperature of cooling channel and process channel were found to be increasing when coolant channel width and height were decreased. Coolant channel to process channel distance was found to have no effect on the heat transfer phenomena. Finally, total heat flux was found to be increasing and maximum coolant channel temperature to be decreasing when coolant channel to coolant channel distance was decreased. Using the qualitative trend revealed from the present study, an appropriate process channel and coolant channel geometry along with the distance between the adjacent channels can be recommended for a microchannel reactor that meet a desired reactor performance on heat transfer phenomena and hence reactor conversion of a Fischer-Tropsch microchannel reactor.

The Effect of Cold Shock on Function and Morphology of Dog Epididymal Spermatozoa (개에서 cold shock이 정소상체유래의 정자의 기능과 형태에 미치는 영향)

  • Yu Il-jeoung
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Dog spermatozoa were recovered from the caudae epididymides of 23 domestic dogs which were 11 pure breed and 12 mix-breed dogs ranging in age from 0.6 to 3 years. The experimental designs were as follows: 1) the effect of chilling to 0. 10 or 37$^{\circ}C$. 2) the kinetics of chilling injury at 0 or 4$^{\circ}C$, and 3) the effect of sugars at $0^{\circ}C$. Viable spermatozoa were recovered by percoll gradient separation and adjusted to 5${\times}$10$^{7}$ spermatozoa/ml. In experiment 1, spermatozoa were diluted with 0.33 M glucose supplemented with 3% BSA (G-BSA) at 1:2 dilution. Spermatozoa were loaded into straws and exposed at 0, 10 or 37$^{\circ}C$ for 30 min. In experiment 2, spermatozoa were prepared as the experiment 1 and exposed for 0.5, 5, 15, or 30 min at 0 or 4$^{\circ}C$. In experiment 3, spermatozoa were diluted with different sugars (0.33 M galactose, glucose, fructose, mannitol, lactose, sucrose, raffinose) and cooled to $0^{\circ}C$ for 30 min. Sperm membrane integrity, motility and acrosome integrity were assayed after rewarming at 37$^{\circ}C$ for 5 min. Sperm motility and membrane integrity abruptly decreased with decreasing temperature but acrosome integrity gradually decreased (P<0.05). Sperm motility was more sensitive to cold shock than membrane integrity and acrosome integrity. Spermatozoa cooled to $0^{\circ}C$ were more damaged than those at 4$^{\circ}C$. Sperm motility was not different among exposed times at both. 0 and 4$^{\circ}C$. However, membrane integrity of spermatozoa exposed for 30 min at both 0 and 4$^{\circ}C$ was significantly lower (P<0.05). Spermatozoa diluted in 0.33 M fructose or galactose showed lower motility and higher morphological abnormality with coiled tail at $0^{\circ}C$. These sperm characteristics were strongly related. These results indicate that dog epididymal spermatozoa are relatively sensitive to rapid cooling and higher morphological abnormality at $0^{\circ}C$ was shown in spermatozoa diluted in fructose and galactose.

Predicting the Effects of Rooftop Greening and Evaluating CO2 Sequestration in Urban Heat Island Areas Using Satellite Imagery and Machine Learning (위성영상과 머신러닝 활용 도시열섬 지역 옥상녹화 효과 예측과 이산화탄소 흡수량 평가)

  • Minju Kim;Jeong U Park;Juhyeon Park;Jisoo Park;Chang-Uk Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.481-493
    • /
    • 2023
  • In high-density urban areas, the urban heat island effect increases urban temperatures, leading to negative impacts such as worsened air pollution, increased cooling energy consumption, and increased greenhouse gas emissions. In urban environments where it is difficult to secure additional green spaces, rooftop greening is an efficient greenhouse gas reduction strategy. In this study, we not only analyzed the current status of the urban heat island effect but also utilized high-resolution satellite data and spatial information to estimate the available rooftop greening area within the study area. We evaluated the mitigation effect of the urban heat island phenomenon and carbon sequestration capacity through temperature predictions resulting from rooftop greening. To achieve this, we utilized WorldView-2 satellite data to classify land cover in the urban heat island areas of Busan city. We developed a prediction model for temperature changes before and after rooftop greening using machine learning techniques. To assess the degree of urban heat island mitigation due to changes in rooftop greening areas, we constructed a temperature change prediction model with temperature as the dependent variable using the random forest technique. In this process, we built a multiple regression model to derive high-resolution land surface temperatures for training data using Google Earth Engine, combining Landsat-8 and Sentinel-2 satellite data. Additionally, we evaluated carbon sequestration based on rooftop greening areas using a carbon absorption capacity per plant. The results of this study suggest that the developed satellite-based urban heat island assessment and temperature change prediction technology using Random Forest models can be applied to urban heat island-vulnerable areas with potential for expansion.

The Development of Insecticidal Soaps and Organic Control of Aphid (CODEX 유기농업허용 살충비누 제조와 진딧물 방제연구)

  • Lee, Tae-Geun;Yoon, Sung-Hee;Park, Dong-Yun
    • Korean Journal of Organic Agriculture
    • /
    • v.10 no.3
    • /
    • pp.87-99
    • /
    • 2002
  • The development of insecticidal soaps made by various fatty acids and organic control for insect by using of insecticidal soap(fatty acid salts) were employed. And the results were as follows: 1. To determine the input volume of potassium hydroxide for saponification of fatty acids, there were compared to individual acid value of fatty acids. in case of coconut fatty acids for saponification was 266.3 mg of potassium hydroxide(266 g/1kg of fatty acid) was calculated. 2. To make the 25% soap content by coconut fatty acids, there was required for the 266g of potassium hydroxide and 3,459 liter of soft water. Then the liquor of soap was 4,644 liter. 3. The progress of insecticidal soap made by fatty acids was accomplished indirect heating and stirring reactor (1)to make the volume of potassium hydroxide solution and warming up(90$^{\circ}$) (2)input volume of individual fatty acid (3)more than 30 min stirring reaction (4)cooling progress. 4. Insecticidal value of insecticidal soap was observed more than 92% the dilution of 50 dilution solution in consecutive 5 days of 2 treatments of the 25% soap made by coconut fatty acids on the red pepper. And insecticidal value of insecticidal soap was observed more than 94% the 100 dilution solution in consecutive 5 days of 3 treatments of the 25% soap made by coconut fatty acids on red pepper and cabbage. 5. The treatment of two times of 25% soap made by coconut fatty acids at the 50 dilution solution and 100 dilution solution in spider mite on red bean has 100% insecticidal value. 6. There was no observation phytotoxic sypmtons on red pepper in field, except for 25% soap made by carprylic acid. 7. Over the two times over 0.1% in addition of isopropyl alcohol was to improvement the insecticidal effect, but there was no effect in addition of diatomaceous earth.

  • PDF

CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity (스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석)

  • Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 2020
  • The natural change of winter night temperature from 00:00 to 04:30 O'clock with the different height of thermal screen in a venlo type glasshouse (W59×L68×H5.9 m) was studied using computational fluid dynamics (CFD). At the early stage of CFD analysis, the room temperature decrease of glasshouse with the 5.9 m height of thermal screen were faster than it with the 4.1m height of thermal screen, but at 2 hr after analysis it was slower than in it with the 4,1m, the temperature difference was 0.6℃ after 4 hr. If we consider that turn on the heater when the temperature were decrease below 13℃ at 1hr after CFD analysis, it is good for energy saving in the glasshouse with the 4.1 m height of thermal screen rather than in it with the 5.9 m height, because of the temperature decrease were slow during 2 hrs after analysis. The airflow at the height of 2 m which were grown tomato were fast and wide in the glasshouse with the 5.9 m height thermal screen rather than in it with the 4.1 m, the speed difference was 0.034m·s-1 at 1hr after CFD analysis. The effect of temperature decrease in summer season were compared with the different height of shading screen from 12:00 to 14:30 O'clock. The height of shading screen were 5.7, 3.9 m, the gap of it were 30%. The air-inflow quantity by the fan with duct at lower part of venlo glasshouse was 0.67 ㎥·s-1 until 1hr and to increase 3 times of it from 1hr after analysis. The roof window were open 100%. Until 1hr of CFD analysis, the temperature in the 30% open of shading screen was 0.9℃ higher than in the none shading screen. From 13:00 O'clock when the air-inlet quantity to increase 3 times, the temperature in case 30% gap of shading screen were decreased compare with the none shading screen, the temperature difference was 0.5℃ at 14:30 O'clock. The temperature on the floor surface in case 30% gap of shading screen were lower with it's height increase, the temperature difference was 8℃ compare with none shading screen. The relative humidity difference were insignificant by the height and gap of shading screen.