• Title/Summary/Keyword: Cooling characteristic

Search Result 382, Processing Time 0.031 seconds

Preparation of PVDF Hollow Fiber Membrane via TIPS (Thermally Induced Phase Separation) and Stretching (열유도 상분리와 연신공정을 이용한 PVDF 중공사막의 제조)

  • Park, Minsoo;Kim, Jinho;Jang, Moonseog;Kim, Sung Soo
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • In this research, microporous and bicontinuous poly vinylidene fluoride(PVDF) hollow fiber membranes were prepared via hybrid process of the thermally induced phase separation (TIPS) and stretching method. The mechanism of the membrane preparation is based on liquid-liquid phase separation. The final membranes have characteristic structures which have both bicontinuous and fibrillar morphology by applying the stretching method. They showed quite different structure when compared with the spherulitic or nodular structure from S/L TIPS and bicontinuous structure from L/L TIPS. At first, PVDF hollow fiber precursors were prepared via TIPS method using various kind of diluent mixtures. We used gamma-butyrolacton, dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP) as diluents. We could make hollow fiber membranes which had porous outer surface or dense outer surface by controling the parameters such as cooling conditions, PVDF concentration and the ratio of diluent mixtures. Finally, these hollow fiber were stretched at room temperature and diluents were extracted by ethanol. Effects of the stretching ratio on the membrane morphology were investigated using scanning electron microscope (SEM), and its effects on water flux, porosity, pore size, roughness and tensile strength were examined.

Operating Criteria of Core Exit Temperature in Nuclear Power Plant with using Channel Statistical Allowance (총채널 불확실도를 적용한 원전 노심출구온도의 운전가능 판정기준)

  • Sung, Je Joong;Joo, Yoon Duk;Ha, Sang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.166-171
    • /
    • 2014
  • Nuclear power plants are equipped with the reactor trip system (RTS) and the engineered safety features actuation system (ESFAS) to improve safety on the normal operation. In the event of the design basis accident (DBA), a various of post accident monitor(PAM)systems support to provide important details (e.g. Containment pressure, temperature and pressure of reactor cooling system and core exit temperature) to determine action of main control room (MCR). Operator should be immediately activated for the accident mitigation with the information. Especially, core exit temperature is a critical parameter because the operating mode converts from normal mode to emergency mode when the temperature of core exit reaches $649^{\circ}C$. In this study, uncertainty which was caused by exterior environment, characteristic of thermocouple/connector and accuracy of calibrator/indicator was evaluated in accordance with ANSI-ISA 67.04. The square root of the sum of square (SRSS) methodology for combining uncertainty terms that are random and independent was used in the synthesis. Every uncertainty that may exist in the hardware which is used to measure the core exit temperature was conservatively applied and the associative relation between the elements of uncertainty was considered simultaneously. As a result of uncertainty evaluation, the channel statistical allowance (CSA) of single channel of core exit temperature was +1.042%Span. The range of uncertainty, -0.35%Span ($-4.05^{\circ}C$) ~ +2.08%Span($24.25^{\circ}C$), was obtained as the operating criteria of core exit temperature.

Consideration in the Interpretation of the Ondam-tang Prescription (온담탕(溫膽湯)의 방론(方論)에 관한 고찰)

  • Choe, Ung-Sik;Jeong, Gi-Hoon
    • Herbal Formula Science
    • /
    • v.22 no.1
    • /
    • pp.65-78
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the interpretation of the Ondam-tang(Ondam-tang, here-in-after referred to as "ODT") prescription in order to obtain the evidence for clinical applications. Methods : We have analyzed the interpretation on the ODT prescription through translations and comparisons based on classic books about the oriental medical prescriptions. Result : 1. ODT was first mentioned in the Jiyangfang(集驗方) which was quoted in the Waitaimiyao (外臺秘要). After that, in book Sanyinjiyibingzhengfanglun(三因極一病證方論), Chen-yan(陳言) completed and recorded in a book organizing prescriptions of ODT now in frequent use. 2. The Banha(半夏) removes the dam(痰-phlegm) and relieves emesis. The Jinpee(陳皮) encourages strengths, and the Bokryoung composes oneself and produces the water. The Licorice(甘草) relieves people's mind, and the Ginger relieves gastrointestinal problems and relieves emesis. Juk-yeo(竹茹) abate of the fever of the Sangcho(上焦). Jisil(枳實) encourages strength, controlling Samcho(三焦) as releasing the congestion of energy. In these ways, numerous symptoms resulted from the imbalances of the Gallbladder(膽) are treated. 3. Meaning of "on(溫-warm)" in ODT regains the original characteristic of the Gallbladder(膽). 4. Treatment mechanism of ODT is 'cooling the Gallbladder(膽)' and 'remedies Samcho(三焦)' and 'eliminates dam(痰)' and 'cure Kiwool(氣鬱-which is kind of depressions) and Saengyen(生涎-which is kind of phlegm)' and 'removes a mismatch between Gallbladder(膽) and Stomache(胃)'. Conclusion : In this study, we have demonstrated various methodologies. This paper will be useful to the future researchers and clinicians to conduct a study on herbal medicines such as the ODT.

Performance Analysis of New Working Solution for Absorption Refrigeration Machine using Treated Sewage (하수처리수이용 신용액 흡수식 냉동기의 성능해석)

  • 권오경;유선일;윤정인
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.231-240
    • /
    • 1998
  • The global environmental problems such as CFC, energy losses in heat recovery system as well as summer peak time power demands, the development of high efficiency absorption refrigeration systems is one of the most promising method in this problems. The absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cucles with parallel or series flow type has been performed. LiBr+LiI+LiCl+LiNO$_3$ solution was selected as the new working fluid. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficient of performance in the parallel or series flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared LiBr solution to evaluate. The absorption refrigeration machine using the new working fluid was obtained better results COP rise and compactness of system by comparison with LiBr solution.

  • PDF

A Characteristic of microstructural evolution, microhardness and tensile properties in CrMoV rotor steel weldment experienced by the cyclic thermal aging heat treatment (CrMoV강 용접부의 주기적 열시효처리에 따른 미세조직, 미세경도 및 인장강도 특성)

  • Kim, G.S.;Koh, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.4
    • /
    • pp.303-312
    • /
    • 1999
  • An investigation of the CrMoV rotor steel weldment which experienced by cyclic thermal aging heat treatment and as-received condition was performed. This evaluation was carried out to confirm whether this type of weldment is appropriate for the service environment in terms of microstructural examinations, microhardness measurements and tensile tests. The cyclic thermal aging heat treatment, containing continuous heating and cooling thermal cycle was programmed to simulate the real rotor service condition. The heat treatment was performed for 40 cycles(5920hrs). The results indicated that the weldment was composed of 4 different regions such as heat affected zone of the base metal, butter weld(initial weld), full thickness weld(final weld) and the base metal. The double welding process was applied to eliminate the susceptibility of reheat cracking at heat affected zone of base metal. The grain refinement at the HAZ due to the welding process could reduce the possibility of cracking susceptibility, but its tensile properties was appeared to be low due to the weld metal in as-received condition. The benefit effect, grain refinement was extended with carbides coarsening during the cyclic thermal aging heat treatment. However the poor mechanical properties of the weldment was more degraded as undergoing the heat treatment.

  • PDF

Heat Transfer Characteristics in the Evaporator of a Soft Ice Cream Maker (소프트 아이스크림 제조기 증발기의 전열 특성)

  • Byun, Ho-Won;Lee, Jin-Wook;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1466-1473
    • /
    • 2012
  • Soft icecream is made by scraping an ice formed on the inside of the cylindrical evaporator, where R-404A is evaporating in the annulus. The heat transfer characteristics of the refrigerant evaporation and those during icecream formation were experimentally investigated. Results show that the refrigerant-side heat transfer coefficients are highly dependent on the location in the evaporator due to the complex annulus configuration. The heat transfer coefficient at the inlet is generally lower than those of other locations. The average heat transfer coefficient increases as heat flux increases or saturation temperature decreases. A correlation is developed to predict the refrigerant-side heat transfer coefficient. The icecream-side heat transfer coefficient oscillates continuously due to the periodic removal of ice formed on the surface. The average heat transfer coefficient during icecream formation is approximately 280 W/$m^2K$, and that during single-phase cooling increased from 150 W/$m^2K$ to 250 W/$m^2K$.

An Evaluation of Application Possibility of Window System in the Building based on Optical Characteristics Analysis of DSSC (염료감응태양전지의 광학특성분석을 통한 건축창호 적용가능성 평가 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Jeong, Seon-Yeong;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.109-115
    • /
    • 2011
  • It can gain both the electric energy production and disperse of light at the same time if DSSC is applied in the building as window system. It means to help facade design and to be used in lighting, heating, cooling energy directly by applicating DSSC BIPV window that is possible to daylighting and materialization of color. For this, optical characteristics analysis that is basic step must take precedence. So, basic databases of DSSC are builded and optical performances according to the double and triple glazing are evaluated by analyzing spectral data of various colored DSSC. As a result, Green(4) has the highest visible transmittance that is 28.8%, and Blue(3) has the lowest that is 0.3%. And, in case of optical performance of Green(4) depending on the incidence angle, SHGC and Tsol are decreased sharply from more than $60^{\circ}C$. Finally, It is judged that Red(4), Green(1), (4), Blue(4) are suitable for application in office building because visible transmittance is high and solar heat gain coefficient is low relatively in spite of composing to double and triple glazing.

Occurence of Ilmenite on the Ti-bearing Ore Bodies in Bukcheon, Hadong Area (하동군 북천면 지역 함티타늄광체 내 티탄철석의 산출특성)

  • Kwak, Ji Young;Choi, Jin Beom
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.197-205
    • /
    • 2014
  • Study area (Jikjeon-ri) is located in south end of the Hadong anorthositic rocks. And along the south-western boundary, diorite intruded the Hadong anorthosite. Ilmenite ore bodies are extended in both anorthosite and diorite. And their occurrence in the diorite are not studied yet. While no particular textures are found in the ilmenite within the anorthosite, the ilmenite within the diorite shows characteristic exsolution texture, that is, ilmenite phases are separated into rutile and Fe-oxide and the ilmenite and Fe-oxide. MnO composition in ilmenite ratios are 2.14~3.74wt%, it has higher composition in diorite than that in anorthosite. The plagioclase composition display andesine ($An_{28.7-42.9}$) in the diorite and labradorite ($An_{57.1-72.8}$) in the anorthosite in composition. The exsolution of ilmenite has been developed during the cooling of partly melted ilmenite into rutile and Fe-oxides which is related to the intrusion of the diorite.

Combustion Test Results of 1/2.5-scale Thrust Chamber for 75tonf-Class Liquid Rocket Engine (75톤급 액체로켓엔진 1/2.5-scale 연소기 연소시험 결과)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Lee, Kwang-Jin;Lim, Byoung-Jik;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.69-73
    • /
    • 2009
  • Combustion test results of 1/2.5-scale thrust chamber for 75tonf-class liquid rocket engine were described. The thrust chamber has chamber pressure of 60 bar, propellant mass flow rate of 89 kg/s, and nozzle expansion ratio of 12. The combustion tests were conducted to verify the combustion performance, the regenerative cooling performance and the durability of thrust chamber at design point condition, and then were performed to confirm the operation and the combustion performance at low combustion pressure condition. All the tests had been successfully executed without the damage of the hardware. These test results present a possibility of hot firing test at low combustion pressure condition, and can be used as fundamental data to predict the combustion performance at design point condition for 75 tonf thrust chamber.

  • PDF

Numerical Study of Flow Characteristics over Square Cylinders with an Attached Splitter Plate

  • Nguyen, Van Minh;Koo, Bon-Guk
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.86-95
    • /
    • 2018
  • The fluid flow over structures has been widely investigated by many researchers because its extensive application in offshore structures, skyscrapers, chimneys and cooling towers, brides. In the viewpoint of reducing the drag for offshore structure, it becomes challenging problem in the field of hydrodynamic of offshore structure. The purpose of this study is to investigate a flow over a square cylinder with an attached splitter plate using RANS method. First, RANS turbulent models such as a standard $k-{\omega}$ model, SST $k-{\omega}$ model, RNG $k-{\varepsilon}$ model, realizable $k-{\varepsilon}$ model, standard $k-{\varepsilon}$ model were used for choosing suitable turbulent model which has the best agreement with available experimental result. Drag of single cylinder estimated by using standard $k-{\omega}$ has a good agreement with published experimental result. Therefore, the stand $k-{\omega}$ was selected for simulation for flow over a square cylinder with an attached plate. Second, the numerical results of drag of square cylinder with an attached splitter plate in various length of an attached plate were performed using RANS method in ANSYS Fluent. In this paper, the numerical simulations were conducted at a Reynolds number of 485 and the thickness of the splitter plate is chosen as a constant value about 10% of cylinder width. The numerical results of drag coefficient of square cylinder are compared with experimental result published by other researchers. Finally, the effect of the splitter plate attached to the rear side of the square cylinder has been investigated numerically with a focus on the drag coefficient and flow characteristic. As a result, the drag coefficient decreases with an increase in splitter plate length.