• 제목/요약/키워드: Cooling and Heating

검색결과 1,915건 처리시간 0.029초

Effects of resistant starch on anti-obesity status and nutrient digestibility in dogs

  • Hyun-Woo Cho;Kangmin Seo;Ju Lan Chun;Junghwan Jeon;Chan Ho Kim;Sejin Lim;Si Nae Cheon;Ki Hyun Kim
    • Journal of Animal Science and Technology
    • /
    • 제65권3호
    • /
    • pp.550-561
    • /
    • 2023
  • This study investigated the effects of corn resistant starch (RS) on the anti-obesity properties, nutrient digestibility, and blood parameters in healthy beagles. Four spayed and six castrated beagle dogs were divided into a control group (CON) with a diet comprising rice and chicken meal and a treatment group (TRT) with a diet comprising corn with an increased RS content by heating-cooling and chicken meal. All dogs in the CON and TRT groups were fed a 1.2-fold higher energy diet than the daily recommended energy requirement for 16 weeks. Throughout the study period, the body weight of dogs in CON increased, whereas no change in body weight was observed in TRT, resulting in a significant difference in body weight between the two groups at the end of the experiment. Moreover, a significant reduction in the apparent total tract digestibility was observed upon the analysis of dry matter, nitrogen-free extract, and organic matter in TRT compared with that in CON. The complete blood cell composition and biochemical parameters were within the reference range in both groups. A significant increase in the concentration of serum adiponectin was found in TRT at the end of the experiment. These results suggest that the corn RS may be beneficial for weight management owing to its reduced nutrient digestibility.

표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출 (Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis)

  • 이천규;정효재
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.

진안 하초 마을숲의 온도 조절 기능 분석 (Analysis on Ground Temperature Arrangement Function of Jinan Macho Village Grove)

  • 박재철;정경숙;장혜화
    • 농촌계획
    • /
    • 제9권4호
    • /
    • pp.35-41
    • /
    • 2003
  • The purpose of this study is on identifying the function of ground temperature arrangement of village grove. Case study was accomplished at Hacho village grove in Jinan-gun, Jeonbuk province. Hacho village grove was the largest grove of all and most formal grove in Jinan region. So ground temperature of outside and inside of Hacho village grove were measured from March to October in 2001. And comparative review about difference between outside and inside of village grove was accomplished. Our ancestors, in spite of orient and occident, have made a settlement in consideration of climatic conditions. We have to team from past pattern and add modern scientific technology. So traditional wisdom and wise planning process must be considered in order to create qualitative residential environment in present through natural elements. It is identified that in winter, the inner side ground temperature is higher than outside one of that and in summer, in contrary, the inner side one of that is lower than outside one of that. So it is identified that Macho village grove breaks winds and reduce the heating energy in winter, it reduces ground temperature and reduces cooling energy very well in summer. It is identified that village grove reduce ground temperature in summer better than any other season. It is identified that in summer, the effect of maintaining constant temperature is also better than my other season. So it is identified that village grove stabilize most changeable outside temperature in inside of that.

사출/압축 및 RHCM 기술이 7인치 도광판 마이크로 패턴 전사성에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Replication Ratio of Micro Patterns of 7 inch LGP using Injection/Compression and RHCM)

  • 조성우;김종선;황철진;윤경환;강정진
    • 소성∙가공
    • /
    • 제20권1호
    • /
    • pp.11-16
    • /
    • 2011
  • Recently, according to the rapid development of display, many display applications, such as, cellular phone, navigation, monitor and LCD TV have been changed from CRT type to LCD type. BLU(Back Light Unit) is one of main parts in LCD unit and generally, it consists of a light source, a reflective sheet, a LGP(Light Guide Plate), a diffuser sheet, and two prism sheets. The most important component of BLU is a light guide plate, which diffuses the input light to the TFT-LCD module uniformly. The LGP is usually made by injection molding process, and it has numerous optical micro patterns on the surface. In the present study the micro-patterned stamper which has cylindrical shape was fabricated by using the UV-LiGA process. And the replication characteristics have been compared among three different kinds of injection molding process; general injection molding, injection/compression molding and RHCM(Rapid Heating and Cooling Molding). Average replication ratios of CIM and ICM were 19.1% and 64.6%, respectively. On the other hand, the average replication ratio of RHCM process showed the higher value of 98.4% among these. It show that maintaining the mold surface above $T_g$ could increase the replication ratio of micro patterns substantially.

염료감응태양전지의 광학특성분석을 통한 건축창호 적용가능성 평가 연구 (An Evaluation of Application Possibility of Window System in the Building based on Optical Characteristics Analysis of DSSC)

  • 심세라;윤종호;정선영;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.109-115
    • /
    • 2011
  • It can gain both the electric energy production and disperse of light at the same time if DSSC is applied in the building as window system. It means to help facade design and to be used in lighting, heating, cooling energy directly by applicating DSSC BIPV window that is possible to daylighting and materialization of color. For this, optical characteristics analysis that is basic step must take precedence. So, basic databases of DSSC are builded and optical performances according to the double and triple glazing are evaluated by analyzing spectral data of various colored DSSC. As a result, Green(4) has the highest visible transmittance that is 28.8%, and Blue(3) has the lowest that is 0.3%. And, in case of optical performance of Green(4) depending on the incidence angle, SHGC and Tsol are decreased sharply from more than $60^{\circ}C$. Finally, It is judged that Red(4), Green(1), (4), Blue(4) are suitable for application in office building because visible transmittance is high and solar heat gain coefficient is low relatively in spite of composing to double and triple glazing.

지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가 (LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads)

  • 전지홍;최동혁;김태동
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

Development of SMH Actuator System Using Hydrogen-Absorbing Alloy

  • Kwon, Tae-Kyu;Jeon, Won-Suk;Pang, Du-Yeol;Choi, Kwang-Hun;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1328-1333
    • /
    • 2005
  • This paper presents the temperature-pressure characteristics of a new SMH actuator using a Peltier module. The SMH actuator is characterized by its small size, low weight, noiseless operation, and compliance similar to that of the human body. The simple SMH actuator, consisting of the plated hydrogen-absorbing alloys as a power source, Peltier elements as a heat source, and a cylinder with metal bellows as a functioning part has been developed. To improve the thermal conductivity of the hydrogen-absorbing alloy, an assembly of copper pipes has been used. It is well known that hydrogen-absorbing alloys can reversibly absorb and desorb a large amount of hydrogen, more than about 1000 times of their own volume. The hydrogen equilibrium pressure increases when hydrogen is desorbed by heating of the hydrogen-absorbing alloys, whereas by cooling the alloys, the hydrogen equilibrium pressure decreases and hydrogen is absorbed. The new special metal hydride (SMH) actuator uses the reversible reaction between the heat energy and mechanical energy of a hydrogen absorbing alloys. The desirable characteristics of SMH actuator, which makes it suitable for the uses in medical and rehabilitation applications, have been also studied. For this purpose, the characteristics of the new SMH actuator for different temperature, pressure, and external load were explored.

  • PDF

서열과 한냉 자극에 대한 반복 국소 노출이 혈류량 및 심박수에 미치는 영향 (Effect of local heating and cooling on blood flow and heart rate.)

  • 박순자
    • 한국농촌생활과학회지
    • /
    • 제5권1호
    • /
    • pp.1-8
    • /
    • 1994
  • 온랭 열 자극에 대하여 인체의 말초 혈류량과 심박수가 어떻게 반응하는가를 관찰하기 위하여 건강한 성인 여자 4명을 피험자로 실험군과 비교군으로 나누어 실험을 실시하였다. 실험군은 온랭열 자극의 단기 훈련을 12회 실시하고 비교군은 실험군의 초기와 말기 2회 실시하여 얻은 결과를 비교ㆍ검토하여 다음과 같은 결과를 얻었다. $\circled1$ 실험군에서의 손가락 혈류량의 초기 반응은 훈련 후에 민감해졌다. $\circled2$ 심박수는 냉수 노출시보다 온수 노출시 증가하였다. $\circled3$ 실험군과 비교군간에는 혈류량의 변화 형태와 심박수에 차이가 있었다. 이상에서 E-군과 C-군의 혈류량과 심박수에서 차이를 나타낸 것은 단기 훈련 효과에 의한 것으로 추정된다.

  • PDF

경기$\cdot$인천지역 중학교 가정실 실내 환경과 활용 실태 (Interior Environment and Practical Usages of the Home Economics Practice Room in Middle School of Gyeonggi and Incheon)

  • 조재순;소복례
    • 한국가정과교육학회지
    • /
    • 제16권4호
    • /
    • pp.127-140
    • /
    • 2004
  • 이 연구는 중학교 가정 교과 특별실인 가정실의 실내 환경. 교구와 설비, 활용 실태의 문제점을 파악하는데 목적이 있다 연구 자료는 경기도와 인천광역시에 소재한 중학교의 가술 $\cdot$ 가정을 담당하고 있는 150명의 교사를 대상으로 우편을 통한 설문지로 수집되었다. 조사 결과 대부분의 중학교는 가정실을 갖추고 있었다. 가정실은 가정 수업 외 다른 용도로 사용되어 때때로 가정실에서의 수업에 어려움을 주고 있었다. 가정실의 활용 실태는 저조하며 대부분 조리와 재봉수업으로 제한되었는데 그 이유는 실내 환경에서 냉$\cdot$난방과 환기의 부적합. 작업대와 의자 같은 설비뿐만 아니라 교구 등의 부족으로 나타났다. 교사들은 가정실에서 모든 단원의 가정수업이 다양한 형태로 이루어지기를 바라고 있었다. 가정실의 실내 환경과 교구의 개선은 가정실에서의 다양한 수업을 수월하게 할 것이다.

  • PDF

R170/R290 혼합냉매 적용 히트펌프 성능 평가 (Performance of Heat Pumps Charged with R170/R290 Mixture)

  • 박기정;이철희;정동수
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.