• 제목/요약/키워드: Cooling Time

검색결과 1,641건 처리시간 0.031초

진공냉각장치와 그 이용 (Vacuum Cooling System and Their Use)

  • 김명환;김경근;박형진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.7-16
    • /
    • 1995
  • This article describes the working prnciple, structure and main characteristics of vacuum coolers for vegetables, and gives concrete examples of vacuum coolers that srebeing put to practical use. In particular, newly-developed cavuum coolers with cold storage, utilizing night-time electricity, are focused upon. Processing plants for vegetables, cold-storage rooms and vacuum cooling devices were investigated as possible application of vacuum cooling technology.

  • PDF

방사능비 $^{l44}Ce /^{l37}Cs$ 검출에 의한 사용후핵연료 냉각기간 결정 (Cooling Time Determination of Spent Nuclear Fuel by Detection of Activity Ratio $^{l44}Ce /^{l37}Cs$)

  • Lee, Young-Gil;Eom, Sung-Ho;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.237-247
    • /
    • 1993
  • 반감기가 서로 크게 다른 두 종류의 방사성 직접핵분열생성물의 방사능비(activity ratio)를 핵연료의 냉각기간 및 연소이력의 함수로 표현하였으며 연소이력에는 사용후핵연료의 평균연소도, 연소기간, 연소주기간의 간격 그리고 주 핵분열물질등이 포함되었다. 고리 1호기에서 연소된 6개의 사용후 가압경수로(PWR) 핵연료 집합체로 부터 36개의 시료를 제작하여 이들 시료에 대한 감마선 스펙트럼을 고순도(HP) Ge 검출기를 사용하여 수집한 후, 각 스펙트럼을 분석하여 얻은 방사능비 $^{l44}$Ce $^{l37}$ Cs를 이용하여 냉각기간을 계산하였다. 그 결과 $^{l44}$Ce 감마선 검출계수율이 $10^{-3}$ cps(count per second) 정도로 아주 낮았음에도 불구하고 검출된 방사능비 $^{l44}$Ce $^{l37}$ Cs를 사용하여 구한 냉각기간은 원자로 운전기록에 의한 냉각기간 (operator declared cooling time)과 상대적인 차이가 $\pm$5% 이내로 잘 일치한 것으로 부터 핵 분열 생성물 $^{l44}$Ce 및 $^{l37}$ Cs은 냉각기간 결정을 위한 좋은 모니터가 됨을 확인하였다. 여러가지의 연소 이력을 갖는 핵연료를 대상으로 한 본 실험의 경우, 단순하게 모델화한 연소이력을 대입하여 얻은 냉각기간은 실제 연소이력을 대입하여 얻은 냉각기간과 시간차이가 $\pm$0.5년 이내에서 잘 맞았으며 이로부터 연소이력에 대한 정확한 정보 없이도 신뢰할 수 있는 정도의 냉각기간을 추정하는 것이 가능할 것으로 생각되었다. 아울러 냉각기간 결정을 위한 본 기술을 활용한 사용후 핵연료의 증명 및/또는 분류에 대한 타당성 연구를 한 결과 감마선 분광분석 방법으로 검출한 방사능비 $^{l44}$Ce $^{l37}$ Cs에 의해서 결정된 냉각기간은, 조사후시험시설 (post irradiation examination facility)등과 같이 사용후핵연료 집합체를 해체 또는 절단하여 만든 시료를 취급하는 시설등에서,사용후핵연료에 대한 안전관리 및 계량관리를 위하여 유용하게 활용될 수 있을 것으로 사료되었다.것으로 사료되었다.

  • PDF

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제5권5호
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

Study of random characteristics of fluctuating wind loads on ultra-large cooling towers in full construction process

  • Ke, S.T.;Xu, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • 제26권4호
    • /
    • pp.191-204
    • /
    • 2018
  • This article presents a study of the largest-ever (height = 220 m) cooling tower using the large eddy simulation (LES) method. Information about fluid fields around the tower and 3D aerodynamic time history in full construction process were obtained, and the wind pressure distribution along the entire tower predicted by the developed model was compared with standard curves and measured curves to validate the effectiveness of the simulating method. Based on that, average wind pressure distribution and characteristics of fluid fields in the construction process of ultra-large cooling tower were investigated. The characteristics of fluid fields in full construction process and their working principles were investigated based on wind speeds and vorticities under different construction conditions. Then, time domain characteristics of ultra-large cooling towers in full construction process, including fluctuating wind loads, extreme wind loads, lift and drag coefficients, and relationship of measuring points, were studied and fitting formula of extreme wind load as a function of height was developed based on the nonlinear least square method. Additionally, the frequency domain characteristics of wind loads on the constructing tower, including wind pressure power spectrum at typical measuring points, lift and drag power spectrum, circumferential correlations between typical measuring points, and vertical correlations of lift coefficient and drag coefficient, were analyzed. The results revealed that the random characteristics of fluctuating wind loads, as well as corresponding extreme wind pressure and power spectra curves, varied significantly and in real time with the height of the constructing tower. This study provides references for design of wind loads during construction period of ultra-large cooling towers.

판형 열교환기를 이용한 과냉각수용액에서 유동과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger)

  • 이동규;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.647-653
    • /
    • 2007
  • In dynamic ice storage system(DISS), ice slurry is formed not only from solution freezing by mechanical removing parts but also supercooled solution. However, in order to perform continuous ice formation in the system without mechanical moving parts, supercooled aqueous solution should be formed stable through cooling heat exchanger and be dissolved uniformly in storage tank. In previous study, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

탄소강의 열간 연성에 미치는 저주기 피로 시기와 냉각속도의 영향 (Effects of Onset Time of Fatigue and Cooling Rate on Hot Ductility of Plain Carbon Steel)

  • 박태은;이운해;손광석;이성근;김인수;임창희;김동규
    • 대한금속재료학회지
    • /
    • 제48권3호
    • /
    • pp.210-217
    • /
    • 2010
  • The effects of cooling rate and onset time of fatigue test on hot ductility of plain carbon steels containing 0.06$\sim$0.8 wt.% carbon were investigated at various temperatures. The tensile tested specimen after fatigue strain during cooling showed higher hot ductility than the specimen fatigued and tensile-strained after cooling. With a decreasing cooling rate from solutionizing temperature to test temperature, hot ductility was increased in all temperature ranges, typically in the trough region, and the minimum point of ductility moved to a lower temperature. Also, the depth and width of the trough decreased with lowering the cooling rate.

판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger)

  • 이동규;백종현;홍희기;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

고강도 냉간압조용 중탄소 Cr-Mo 합금강의 임계간 어닐링시 냉각속도 및 온도의 영향 (Effect of Cooling Rate and Temperature on Intercritical Annealing of Medium-Carbon Cr-Mo Alloy for High Strength Cold Heading Quality Wire Rod)

  • 이종혁;장병록
    • 열처리공학회지
    • /
    • 제36권4호
    • /
    • pp.230-236
    • /
    • 2023
  • The current study deals with the effect of cooling rate and temperature for annealing on medium-carbon Cr-Mo alloy steel, especially for cold heading quality wire rod, to derive the optimum micro-structures for plastic deformation. This is to optimize the spheroidization heat treatment conditions for softening the material. Heat treatment was performed under seven different conditions at a temperature between Ac1 and Ac3, mostly within 720℃ to 760℃, and the main variables at this time were temperature, retention time and cooling rate. Microstructure and phase changes were observed for each test condition, and it was confirmed that they were greatly affected by the cooling rate. It was also confirmed that the cooling rate was changed in the range of 0.1℃/min to 5℃/min and affected by phase deformation and spheroidization fraction. The larger the spheroidization fraction, the lower the hardness, which is associated with the increasing connection of ferrite phases.

냉각탑 백연방지의 성능 향상에 관한 실험적 연구 (An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements)

  • 정순영;이병천;김성
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

PCM을 적용한 자연대류형 수냉식 방열기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of the Liquid Cooling Radiator of the Natural Convection Type by Using the PCM)

  • 성대훈;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.324-329
    • /
    • 2008
  • The liquid cooling effect of a natural convection type radiator by using the PCM has been investigated experimentally. The radiator size is $423{\times}295{\times}83$ mm and PCM container size is $398{\times}270{\times}26$ mm. The objective is elapsed time higher than maximum time to reach for maximum operating temperature of a general liquid cooling radiator. This study, in order to study on the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, ambient and melting point of three type PCM. For the above experimental parameter, the melting time was performed about 180/250/560 min at input power 150 W and ambient $30^{\circ}C$ from using the three type PCM(PCM_S1/S2/S3) respectively. Furthermore, the effects of the thermal dissipation was decreased higher input power than lower input power at heating block and melting time of PCM. However, the effects of mass flow rate did not nearly affect of the thermal performance especially.

  • PDF