• Title/Summary/Keyword: Cooling Condition

Search Result 1,247, Processing Time 0.032 seconds

Experimental Study to Nozzle of Vortex Tube (보텍스튜브의 노즐에 대한 실험적 연구)

  • Riu, K.J.;Bang, C.H.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.1-10
    • /
    • 1999
  • The phenomena of energy separation through the vortex tube was investigated experimentally, to see the effect of nozzle area ratio and partial admission rate on the energy separation and cooling capacity. The experiment was tarried out with various nozzle area ratios from 0.031 to 0.232 and partial admission rate from 0.176 to 0.956 by varying input pressure($0.2{\si\m}0.5$ MPa) and cold air mass fraction($y=0.1{\sim}1.0$). From the experimental result, we found the optimum nozzle area ratio and the effective partial admission rate for the available use and best cooling performance in given operation condition. While the maximum drop of cold air temperature was observed at around y=0.3 and $S_n=0.155$, the maximum cooling capacity was observed at around y=0.6 and $S_n=0.094$.

  • PDF

Improvement on the formability of magnesium alloy sheet by heating and cooling method(II) (가열냉각법에 의한 마그네슘합금의 판재성형성개선(II))

  • Manabe K.;Kang Dae-Min
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.385-388
    • /
    • 2005
  • The use of magnesium alloys meets the need of reducing weight of componests(especially in automotive and aerospace industry) keeping unmodified their mechanical properties. The adoption of magnesium alloys in sheet forming processes is still limited, due to their low formability at room temperature caused by the hexagonal crystal structure. In this study, the authors aim to understand the process condition which can lead to a successful improvement in the formability of a magnesium alloy(AZ31). Experiment and simulations of deep drawing were doned at various warm temperature for the blank and tool(holde and die)while the punch was kept at room temperature by cooling wale. in order to confirm that the deep drawing performance of magnesium alloy can be considerably enhanced with using the local heating and cooling technique.

  • PDF

A Study on the Prediction Modeling of Phase Transformation in the CGHAZ of Structural Steel Weld (구조용강 용접부 CGHAZ의 상변태 예측 Modeling에 관한 연구)

  • 조일영;이경종;이창희
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.74-84
    • /
    • 1998
  • The microstructures of the HAZ (Heat Affected Zone) are generally different from the base metal due to rapid thermal cycle during welding process. Particuraly, CGHAZ (Coarsened Grain Heat Affected Zone) near the fusion line is the most concerned region in which many metallurgical and mechanical discontinuities have been normally generated. A computer program by the numerical formularization of phase transformation during cooling with different rates was developed to generate the CCT diagram, and to predict microstructural (phase) changes in the CGHAZ. In order to verify simulated results, isothermal and continuous cooling transformation experiments were conducted. The simulated and experimental results showed that the developed computer model could successfully predict the room temperature microstructural changes (changes in volume fraction of phases) under various welding conditions (heat input & cooling rate $(Δt_{8/5})$).

  • PDF

Effect of pressurization on dissolution of a supercooled aqueous solution with a stationary state (가압조건이 정지상태 과냉각 수용액의 해소에 미치는 영향)

  • Kim, Byung-Seon;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.132-137
    • /
    • 2006
  • Supercooled type ice slurry system is hard to keep a proper supercooling degree when solution becomes supercooling state. This is the reason of the ice blockage in pipe or cooling part due to an unstable cooling state. In this study, a cooling experiment was performed to pressurized solution in a stationary state. The behaviors during the supercooled aqueous solution were investigated at fixed flow rate of brine and aqueous solution of ethylene glycol 7 mass%. Also the effect to the freezing point of supercooled aqueous solution was investigated to the different pressure 101, 202, 303, and 404 kPa. At results, the pressure of the aqueous solution in the cylinder increased the supercooling degree increased and dissolution of supercooled point decreased.

  • PDF

A Study on the Energy Storage System Using Air Source Heat Pump for Heating and Cooling (공기 열원을 이용한 축열식 냉난방 시스템 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Seo, Jeong-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1125-1130
    • /
    • 2006
  • An air source heat pump system producing the ice and water storage energy for cooling and heating of building has been proposed. Cycle design and simulation considering energy balance between heating and cooling capacity has been carried out. The roles of the capacity controlled compressor, refrigerant heating device and air preheating are investigated in detail. System control logic for meeting the predetermined heating capacity when the system is operated at cold climate condition is suggested. Some anticipated problems of the proposed system are also described.

  • PDF

A Study on Electrostatic Chuck Cooling by Ceramic Dielectric Material and Coolant path (세라믹 유전체 물질과 냉매 유로 형상에 따른 정전척 냉각에 관한 연구)

  • Kim, Daehyeon;Kim, Kwangsun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.85-89
    • /
    • 2018
  • Temperature uniformity of a wafer in a semiconductor process is a very important factor that determines the overall yield. Therefore, it is very important to confirm the temperature characteristics of the chuck surface on which the wafer is lifted. The temperature characteristics of the chuck depend on the external heat source, the shape of the cooling channel inside the chuck, the material on the chuck surface, and so on. In this study, CFD confirms the change of temperature characteristics according to the stacking order of ceramic materials and inner coolant path on the chuck surface. Finally this study suggests the best cooling condition of electrostatic chuck.

Novel Wafer Warpage Measurement Method for 3D Stacked IC (3D 적층 IC제조를 위한 웨이퍼 휨 측정법)

  • Kim, Sungdong;Jung, Juhwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.86-90
    • /
    • 2018
  • Standards related to express the non-flatness of a wafer are reviewed and discussed, for example, bow, warp, and sori. Novel wafer warpage measurement method is proposed for 3D stacked IC application. The new way measures heat transfer from a heater to a wafer, which is a function of the contact area between these two surfaces and in turn, this contact area depends on the wafer warpage. Measurement options such as heating from room temperature and cooling from high temperature were experimentally examined. The heating method was found to be sensitive to environmental conditions. The cooling technique showed more robust and repeatable results and the further investigation for the optimal cooling condition is underway.

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

Experimental Study on Indoor Thermal Environment of an Office Building During Cool ing Season (실내 열환경에 관한 실측조사 연구 -냉방기 사무소건물을 중심으로-)

  • Kim, Sung-Wan;Jang, Hai-Jin;Park, Sang-Dong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.3
    • /
    • pp.189-197
    • /
    • 1983
  • In this study, the thermal environment of a certain building was investigated by using of concerned equipments and enquete sheets. The measured items were temperature, humidity, air flow and radiant heat, and thermal responses for the occupants were checked also, which are oriented to be used as basic data for environmental design. The results of this study are as followed. 1. The optimal room temperature was $24\~26.5^{\circ}C$ DBT in cooling season. 2. Under the condition from $50\%\;to\;70\%$ of relative humidity, the difference of relative humidity did not impact upon the feeling temperature. 3. In cooling season, the average clothing factor of occupants was 0.34 clo ; 0.49 clo for men and 0.25 clo for women. 4. The average working factor of occupants was $1.1\~1.3\;Met$ in that cooling season.

  • PDF

A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process (실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구)

  • Lee Hung Joo;Kim Yong Ku
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF