• 제목/요약/키워드: Conversion design

검색결과 2,014건 처리시간 0.031초

A New Controller for Improvement of Response Time by Data Compression Using Color Space Conversion

  • Koo, Sung-Jo;Kim, Chang-Gon;An, Jong-Ki;Park, Man-Hyo;Yeo, Sang-Deog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.863-864
    • /
    • 2005
  • In recent years, we use overdriving scheme to improve the response time of the liquid crystal. Since conventional overdriving scheme uses memory to perform ideal processing, it is desired to reduce system cost by decreasing the data stored in these SDRAMs. As a general compression method, quantization, sub-sampling and Block Truncation Coding ( BTC ) are used, which process data in block base and cause block effect. So we proposed new data compression method by color space conversion. Because this method compresses luminance and chrominance signal by different ratio, it can efficiently reduce error of block effect in decompression image.

  • PDF

Estimating the Soil Volume Conversion Factor of Weathered Ground with Consideration of Field Situations

  • Jin, Kyu-Nam;Cho, Gye-Chun;Lee, Jung-Min;Ryu, Hee-Hwan;Park, Sung-Wook
    • 토지주택연구
    • /
    • 제2권2호
    • /
    • pp.145-155
    • /
    • 2011
  • It is very important for successful construction to estimate the soil volume conversion factor of domestic weathered ground accurately and reasonably. However, it is very difficult to quantify the weathering degree of weathered ground at the field, so that the soil volume conversion factor used in Korea is often dependent upon the standard of foreign countries. Besides, the soil volume conversion factor of domestic weathered ground has been rarely studied and the use and accuracy of the soil volume conversion factor have been questioned persistingly. This study suggests a simple but robust method for estimating the soil volume conversion factor and measuring the weathering degree reasonably, and attempts to establish the utilization of a soil volume conversion factor measurement system based on experimental and analytical results. We made relationship between electrical resistivity and weathering degree presented from weathering index obtained through laboratory tests using field samples, and an estimation method of in-situ weathering degree for granites and a calculation method of soil volume conversion factor using electrical resistivity. And also, we suggested the photogrametry measurement-equipment system for measuring the volume of cargo box and the application plan of stand equipment and RFID for calculating the earth volume and distinguishing buggies in order to design the measurement system for soil volume conversion factor applicable to the field. Ultimately, the Weathered Earth-work Management Program (WEMP) was developed, so field managers may easily obtain the information about earth volume and soil volume conversion factor at the weathered ground.

통계적 실험계획에 의한 폐플라스틱/폐유의 최적 열분해 반응조건 결정 (Determination of Optimum Reaction Conditions for Pyrolytic Coprocessing of Waste Plastics with Waste Motor oil by Statistical Experimental Design)

  • 윤왕래;박종수;정헌;이호태;고성혁;김성현
    • 에너지공학
    • /
    • 제8권1호
    • /
    • pp.189-201
    • /
    • 1999
  • 범용 열가소성 플라스틱(polyethylene(PE), polypropylene(PP), polystyrene(PS), polyethylene-terephthalate(PET), acrylonitrile-butandiene-styrene(ABS))과 폐윤활유의 동시처리 열분해반응 실험을 수행하였다. 반응실험은 40$m\ell$ 용량의 회분식 미분반응기(microreactor)를 이용한 실험과 1리터 용량의 autoclave를 이용한 실험의 두 가지로 구분하여 행하였다. 전자의 경우는 통계적 실험적계획법(statistical experimental design)의 하나인 회전계획실험(rotatable design experiments)으로서 오각형 실험계획(pentagonal experimental design)에 의거한 반응변수 실험을 수행한 후 반응표면(response surface)을 회기분석법에 의하여 분석함으로써 최대의 오일 수율을 얻을 수 있는 최적 반응조건을 추적, 결정하였다. Autoclave 반응실험의 기본적인 목적은 실제 연속공정에 있어서 열분해 반응기 거동을 모사하기 위한 전초단계로서 충분한 시료의 확보를 통하여 이 때 생성된 연로유의 체계적인 분석(비등점분포특성, 진공증류, 기체분석, 원소분석, 발열량, 비중 등)을 행함으로써 연료유 수율 및 품질을 모사하고자 하였다. 미분반응기 실험에 있어서 주 범용열가소성수지인 PE, PP 그리고 PS는 각각의 최적반응조건하에서 거의 100%에 가깝게 오일로 전환되었지만 응축수지인 PET와 그래프트공중합수지인 ABS의 오일수율은 각기 78% 및 90%로서 상대적으로 낮게 나타났다. Autoclave를 이용한 실험의 경우 혼합플라스틱을 폐유에 대하여 40wt% 혼합하여 열분해하였을 때, 80wt% 오일, 15wt% 코우크, 그리고 나머지 5wt%는 탄화수소기체(C1-C6)로 전환되었다. 진공증류(252$^{\circ}C$,2 torr) 결과, 기/액-분리도는 3으로서 이는 생성오일의 75wt%가 경질연료유(가솔린, 등유, 경유)로 회수 가능하였다.

  • PDF

직접변환방식을 이용한 멀티캐리어 디지털 송신기 설계 (Design of Multi-carrier Digital Transmitter Using a Direct Conversion Scheme)

  • 신관호;조성언;오창헌
    • 한국통신학회논문지
    • /
    • 제28권6A호
    • /
    • pp.425-432
    • /
    • 2003
  • 본 논문에서는 직접변환방식을 이용한 CDMA 기지국용 멀티캐리어 디지털 송신기를 설계하고 시뮬레이션을 통해 그 성능을 검증해 보았다. 먼저, 멀티캐리어 송신기를 설계하기 위해 필요한 새로운 기술들을 검토해보고, 이 새로운 기술을 적용하여 멀티캐리어 송신기를 설계하고 시뮬레이션 하였다. 설계와 시뮬레이션은 Agilent Technologies사의 RF 시뮬레이션 S/W인 ADS (Advanced Design System)을 사용하였으며, 디지털 블록과 아날로그 블록으로 나누어 설계한 후 두 블록을 co-simulation하여 결과를 분석하였다. 결과에 의하면, 직접변환방식을 이용하여 멀티캐리어 디지털 송신기를 구현한 경우 최종 아날로그출력이 시스템의 요구조건 (IS-97 & 3G TS 25.104) 인 스펙트럼 마스크 특성을 만족하였다. 이것은 제안한 멀티캐리어 디지털 송신기의 성능이 CDMA 기지국에 적용될 수 있다는 것을 의미한다. 따라서, 본 논문에서 제안한 직접변환방식을 이용한 멀티캐리어 디지털 송신기는 향후 CDMA 기지국에 적용되어 구현될 때, 가격적으로나 기술적으로 한 단계 발전된 시스템을 구현할 수 있다.

유휴 산업시설의 컨버전 사례 분석 - 테이트모던, 발틱 현대미술센터, 루르박물관을 중심으로 - (A Case Study on Conversion of Idle Industrial Facilities - Focus on Tate Modern, Baltic Center for Contemporary Art, and Ruhr Museum -)

  • 조연주;신경주
    • 한국실내디자인학회논문집
    • /
    • 제20권3호
    • /
    • pp.59-68
    • /
    • 2011
  • As society alters and building ages, many industrial facilities lost their function and abandoned in central city areas, and sometimes creating many problems. However, many European countries successfully transformed those urban decay to vivid cultural hub. The purpose of this study was to analyze a concept and methods of converting idle industrial facilities to successful cultural spaces. A case study of Tate Modern, Baltic Center for Contemporary Art, and Ruhr Museum was conducted using literature review, site visit, and interview methods. Findings indicated that converting historically significant idle industrial facilities to cultural center had not only reused abandoned site but also helped regenerating adjacent urban areas. This article demonstrates the key factors of successful conversion strategies as convenience, participation, placeness, historicity, and accessibly; and thus an effort to actively enhance the strategic factors were demanded in future conversion projects. A continuous studies on exploring extensive cases in various perspectives are required for further generalization in future studies.

극저온냉동기 예냉 수소액화기의 기초설계 (Basic design of hydrogen liquefier precooled by cryogenic refirgerator)

  • 김승현;장호명;강병하
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.389-400
    • /
    • 1997
  • A thermodynamic cycle analysis is performed for refrigerator-precooled Linde-Hampson hydrogen liquefiers, including catalysts for the ortho-to-para(o-p) conversion. three different configurations of the liquefying system, depending upon the method of the o-p conversion, are selected for the analysis. After some simple and justifiable models are introduced, a general analysis program to predict the liquid yield and the figure of merit(FOM) is developed with incorporating the commercial computer code for the hydrogen properties. The discussion is focused on the effect of the two primary design parameters-the precooling temperature and the high pressrure of hydrogen. When the precooling temperature is in the range between 45 and 60 K, the optimal high pressure for the maximal liquid yield is found to be in the range between 100 to 140 bar, regardless of the o-p conversion. However, the FOM can be maximized at slightly smaller values of high pressures. It is remarkable to observe that the lower precooling temperatures are favorable since both the liquid yield and the FOM can be obtained without compressing hygrogen to extremely high pressures.

  • PDF

Basic Design of Hydrogen Liquefier Precooled by Cryogenic Refrigerator

  • Kim, Seung-Hyun;Chang, Ho-Myung;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.124-135
    • /
    • 1998
  • A thermodynamic cycle analysis is performed for refrigerator-precooled Linde-Hampson hydrogen liquefiers, including catalysts for the ortho-to-para conversion. Three different configurations of the liquefying system, depending upon the method of the o-p conversion, are selected for the analysis. After some simplifying and justifiable assumptions are made, a general analysis program to predict the liquid yield and the figure of merit (FOM) is developed with incorporating the commercial computer code for the thermodynamic properties of hydrogen. The discussion is focused on the effect of the two primary design parameters - the precooling temperature and the high pressure of the cycle. When the precooling temperature is in a range between 45 and 60 K, the optimal high pressure for the maximal liquid yield is found to be about 100 to 140 bar, regardless of the ortho-to-para conversion. However, the FOM can be maximized at slightly lower high pressures, 75 to 130 bar. It is concluded that the good performance of the precooling refrigerator is significant in the liquefiers, because at low precooling temperatures high values of the liquid yield and the FOM can be achieved without compression of gas to a very high pressure.

  • PDF

스위칭 주파수 가변 방식을 적용한 저전압 배터리 충전용 Dual Active Bridge 컨버터 (Bi-directional Dual Active Bridge Converter applying variable switching frequency for low battery charger)

  • 정동근;김호성;류명효;백주원;김희제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.413-414
    • /
    • 2014
  • This paper proposed an optimized design of a dual active bridge converter for a low-voltage charger. The dual active bridge converter among various bi-directional DC/DC converters is a high-efficiency isolated bi-directional converter. In the general design, when the battery voltage is high, the ZVS region is reduced. In contrast, when the battery voltage is low, the efficiency is low due to high conduction loss. In order to increase the ZVS region and the power conversion efficiency, depending on the battery voltage, variable switching frequency method is applied. At the same duty, the same power is obtained regardless of the battery voltage using the variable switching frequency method. The proposed method was applied to a 5kW prototype converter, and the experimental results were analyzed and verified.

  • PDF

Tubular reactor design for the oxidative dehydrogenation of butene using computational fluid dynamics (CFD) modeling

  • Mendoza, Joseph Albert;Hwang, Sungwon
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2157-2163
    • /
    • 2018
  • Catalytic reactors have been essential for chemical engineering process, and different designs of reactors in multi-scales have been previously studied. Computational fluid dynamics (CFD) utilized in reactor designs have been gaining interest due to its cost-effective advantage in designing the actual reactors before its construction. In this work, butadiene synthesis via oxidative dehydrogenation (ODH) of n-butene using tubular reactor was used as a case study in the CFD model. The effects of coolant and reactor diameter were investigated in assessing the reactor performance. Based on the results of the CFD model, the conversion and selectivity were 86.5% and 59.5% respectively in a fixed bed reactor under adiabatic condition. When coolants were used in a tubular reactor, reactor temperature profiles showed that solar salt had lower temperature gradients inside the reactor than the cooling water. Furthermore, higher conversion (90.9%) and selectivity (90.5%) were observed for solar salt as compared to the cooling water (88.4% for conversion and 86.3% for selectivity). Meanwhile, reducing the reactor diameter resulted in smaller temperature gradients with higher conversion and selectivity.

Primary Energy Conversion in a Direct Drive Turbine for Wave Power Generation

  • Prasad, Deepak Divashkar;Zullah, Mohammed Asid;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.237.1-237.1
    • /
    • 2010
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Ocean contains energy in form of thermal energy and mechanical energy: thermal energy from solar radiation and mechanical energy from the waves and tides. The current paper looks at generating power using waves. The primary objective of the present study is to maximize the primary energy conversion (first stage conversion) of the base model by making some design changes. The model entire consisted of a numerical wave tank and the turbine section. The turbine section had three components; front guide nozzle, augmentation channel and the rear chamber. The augmentation channel further consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. Different front guide nozzle configuration and rear chamber design were studied. As mentioned, a numerical wave tank was utilized to generate waves of desired properties and later the turbine section was integrated. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall which moved sinusoidally with the general function, $x=asin{\omega}t$. In addition to primary energy conversion, observation of flow characteristics, pressure and the velocity in the augmentation channel, rear chamber as well as the front guide nozzle are presented in the paper. The analysis was performed using the commercial code of the ANSYS-CFX. The base model recorded water power of 29.9 W. After making the changes, the best model obtained water power of 37.1 W which represents an increase of approximately 24% in water power and primary energy conversion.

  • PDF