• Title/Summary/Keyword: Convergence ratio

Search Result 1,568, Processing Time 0.027 seconds

Study on Proximal Convergence/Accommodation(PC/A) Ratio by Comparison of Gradient AC/A Ratio and Calculated AC/A Ratio (Gradient AC/A비와 Calculated AC/A비의 비교에 의한 근접성 폭주비(PC/A)에 관한 연구)

  • Han, Gyeong-Ae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.223-231
    • /
    • 2004
  • In most previous studies, the assessment of accommodative convergence to accommodative stimulus (AC/A) ratio was commonly made by measuring gradient AC/A ratio. This study deals with the proximal convergence/accommodation(PC/A)ratio measured by comparing values of the gradient AC/A ratio and the calculated AC/A ratio to prevail the clinical use of the AC/A ratio. Visual acuities of All 124 subjects had been corrected to at least 1.0 with either eye through their habitual refractive correction and the MEM dynamic retinoscopy was performed to estimate their accommodative response. And then the PC/A ratio was calculated by making use of the calculated AC/A ratio and the gradient AC/A ratio. This study showed that the difference between the mean calculated AC/A ratio and the mean gradient AC/A ratio in subgroups may be attributable to proximal convergence. Consequently, further studies on proximity cues including the PC/A ratio could be helpful to prevail the clinical use of the AC/A ratio.

  • PDF

Fatigue Limit According to Microcracks in 0.57 wt.% Carbon Steel with Different HV (HV가 다른 0.57 wt.% 탄소강의 미소 균열에 따르는 피로 한도)

  • Oh, Chang-Seok;Gu, Kyoung-Hee;Lee, Gum-Hwa;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.233-238
    • /
    • 2022
  • This study evaluated the fatigue limit depending on microcracks using 0.57 wt.% carbon steel with different Vickers hardness. The fatigue limit was almost constant up to a certain limit regardless of the carbon content. However, the fatigue limit decreased rapidly as the size of the crack increased. As the crack aspect ratio was smaller, the fatigue limit of the depth (point A) a lot decreased. The fatigue limit ratio of the depth decreased significantly because the crack propagation in the depth direction was fast as the crack aspect ratio became smaller. On the other hand, the fatigue limit ratio of surface cracks increased as the crack aspect ratio decreased.

Proposal for a virtual museum with vertical aspect ratio for the convergence of metaverse and short-form content

  • Il-hyun Cho
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.119-126
    • /
    • 2023
  • This study explores the convergence of metaverse and short-form content, proposing a new approach for viewing short-form content with a vertical aspect ratio on a metaverse platform and within a virtual museum. Short-form content has gained popularity due to the snack culture and is proving to be advantageous in e-commerce. By studying the relationship between vertical ratio screens and gaze, we confirm the effectiveness of vertical ratio short-form content in providing immersive experiences and fostering sharing and communication. The proposed virtual museum offers opportunities for innovative businesses to market through fandom. This research highlights the value of vertical proportion short-form content and its significance in the convergence of metaverse and short-form content. It aims to contribute to industry development, provide new creative directions, enhance personal visual experiences, and expand applicability in related fields.

Numerical Characteristics of Upwind Schemes for Preconditioned Compressible Navier-Stokes Equations (예조건화된 압축성유동 수치기법에서의 풍상차분법의 수치특성 검토)

  • Gill J. H.;Lee D. H.;Choi Y. H.;Kwon J. H.;Lee S. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95-102
    • /
    • 2002
  • Studies of the numerical characteristics of implicit upwind schemes, such as upwind ADI, Line Gauss-Seidel(LGS) and Point Gauss-Seidel(LU) algorithms, for preconditioned Navier-Stokes equations ate performed. All the algorithms are expressed in approximate factorization form and Von Neumann stability analysis and convergence studies are made. Preconditioning is applied for efficient convergence at low Mach numbers and low Reynolds numbers. For high aspect ratio computations, the ADI and LGS algorithms show efficient and uniform convergence up to moderate aspect ratio if we adopt viscous preconditioning based on min- CFL/max- VNN time-step definition. The LU algorithm, on the other hand, shows serious deterioration in convergence rate as the grid aspect ratio increases. Computations for practical applications also verify these results.

  • PDF

AN IMPROVED LOCAL CONVERGENCE ANALYSIS FOR SECANT-LIKE METHOD

  • Argyros, Ioannis K.;Hilout, Said
    • East Asian mathematical journal
    • /
    • v.23 no.2
    • /
    • pp.261-270
    • /
    • 2007
  • We provide a local convergence analysis for Secant-like algorithm for solving nonsmooth variational inclusions in Banach spaces. An existence-convergence theorem and an improvement of the ratio of convergence of this algorithm are given under center-conditioned divided difference and Aubin's continuity concept. Our result compare favorably with related obtained in [16].

  • PDF

Evaluation of Visual Responses in Viewing a 3D Image (3D 영상 시청 시 시각반응의 평가)

  • Lee, Mu-Hyuk;Son, Jeong-Sik;Kim, Jaedo;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.165-170
    • /
    • 2012
  • Purpose: The aim of this study was to measure and evaluate changes of visual responses in viewing a 2D and 3D (three-dimensional) image. Methods: The subjects were 44 college students aged 19 to 25 years with normal binocular vision. The visual responses measured were CA/C (convergence accommodation/convergence) ratio, convergence-induced PD(interpupillary distance), accommodative responses, perceived distance in viewing a 3D image. Results: Convergence and accommodative responses in viewing the 3D image were significantly larger (p<0.05) than in 2D. A moderate positive correction was found between CA/C ratio and accommodative response (r = 0.477, p = 0.001). It was indicated that smaller PD had larger depth perception. Convergence in viewing the 3D image was significantly larger (p<0.05) than that at cognitive distance. Conclusions: The visual fatigue may be more intense in larger CA/C ratio and smaller PD when viewing 3D images.

CA/C Ratio of Adults in Their Early Twenties with Normal Binocular Vision (양안시가 정상인 20대 초반 성인의 CA/C비)

  • Lee, Mu-Hyuk;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the convergence accommodation to convergence (CA/C) ratio and to investigate relationships among age, accommodative amplitude and PD (interpupillary distance) of adults in their early twenties with normal binocular vision. Methods: 44 subjects (mean age, $21.75{\pm}1.16$ years) with healthy eyes were examined. The CA/C ratios were measured by using the difference of Gaussian (DOG) target with retinoscopy. Results: The mean CA/C ratio was $0.052{\pm}0.017$ D/$\Delta$. A moderate negative correction was present between CA/C ratio and age (r = -0.50, p = 0.0005), and a highly positive correction was found between CA/C ratio and accommodative amplitude (r = 0.79, p<0.0001). There was no relation between PD and CA/C ratio. Conclusions: The CA/C ratio presented was mean value for adults in their early twenties with healthy eye between 19 and 25 years of age. There was a high correlation between accommodative amplitude and CA/C ratio. Therefore, the CA/C ratio will be useful basic information for comparison in age, gender and binocular anomalies with similar data from other countries.

ACCURACY AND CONVERGENCE OF THE LOCAL PRECONDITIONING ON THE HIGH ASPECT RATIO GRIDS (가로세로비가 큰 격자에서 국소 예조건화 기법의 정확성 및 수렴성)

  • Lee, J.E.;Kim, Y.;Kwon, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.269-276
    • /
    • 2009
  • The local preconditioning method has both robust convergence and accurate solutions by using local flow properties for parameters in the preconditioning matrix. Preconditioning methods have been very effective to low speed inviscid flows. In the viscous and turbulent flows, deterioration of convergence should be overcame on the high aspect ratio grids to get better convergence and accuracy. In the present study, the local time stepping and min-CFL/max-VNN definitions are applied to compare the results and we propose the method that switches between two methods. The min-CFL definition is applied for inviscid flow problems and the min-CFL/max-VNN definition is implemented to viscous and turbulent flow problems.

  • PDF

An Adaptive Line Enhancer Using Lattice Notch Filters (격자형 노치 필터를 이용한 정현파 검출기)

  • 조남익;최종호;이상욱
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.719-726
    • /
    • 1987
  • In this paper, an adaptive IIR (infinite impulse response) notch filter of lattice type is constructed and its adaptation algorithm is proposed for the detection and retrieval of a sine wave signal embedded in noise. A modified method which adapts only one coefficient of the filter is also suggested. All these methods adapt the coefficients while keepting the poles of the filter inside the unit circle on z-plane, and thus they satisfy the condition on the stability of the IIR filter after it has converged. To investigate the convergence characteristics of these methods such as convergence speed and output S/N ratio, intensive computer simulation has been performed by varying the frequency of the sine wave and the input S/N ratio. And the results of the simulation have been compared to those of Rao and Kung's which shows relatively fast convergence speed. The methods proposed here, especially the second one. shows faster convergence speed and higher output S/N ratio than the Rao and Kung's.

  • PDF

Effects of Swirl Ratio on Combustion Characteristics in DI Diesel Engine (스월비 변화가 직접분사식 디젤기관의 연소특성에 미치는 영향)

  • Kwon, Soon-Ik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.2
    • /
    • pp.149-153
    • /
    • 2003
  • Besides the fuel spray behavior and combustion chamber shape. an air motion has a key role on exhaust gas emission and performance in a DI diesel engine. A swirl ratio represents the ratio of the intake swirl velocity to the engine speed. The main purpose in this work is to investigate the effects of the swirl ratio to the combustion characteristics. A shroud valve machined to change the swirl ratio. Test was carry out by changing the engine speed, nozzle diameter and swirl ratio in a single cylinder diesel engine. From this study, the optimized combustion was found at swirl ratio 2.7. And it was also found that the increasing the maximum cylinder pressure with an increasing swirl ratio lead to decrease a smoke and to increase NOx.

  • PDF