• 제목/요약/키워드: Conventional system

검색결과 14,428건 처리시간 0.045초

전철화된 호남선에서의 전기차량에 의한 전차선로 측정 및 평가 (The measurement and evaluation of catenary system by using electric rolling stock on Honam-Line electrified)

  • 안영훈;현충일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1286-1291
    • /
    • 2004
  • This paper was showed evaluation method and technical items for measurement test of new catenary system of Honam(Daejeon - Mokpo) conventional railway electrified. This line have tested by three type new electric rolling stocks in order to test construction quality and operation safety of a new catenary system with speed-up than conventional speed. We have some important experiences through measurement test of catenary system by new device installed on train roof.

  • PDF

전기로 제어를 위한 전문가 시스템 (Expert system for electrical furnace)

  • 명노직;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.113-116
    • /
    • 1990
  • In this paper, An expert system for electric furnace with time delay is proposed. The expert system uses Fuzzy control theory. The conventional controller uses Auto-Tuning control theory. From experiment, we can obtain that the response of expert system is superior to the response of the conventional controller. In this experiment, the expert controller is implemented with the IBM PC. The 8751 One chip processor controling the electric furnace is used.

  • PDF

TFM에 대한 내장형제어기의 위험측고장률 예측에 관한 연구 (A study on a Prediction of Dangerous Failure Rate in the Embedded System for the Track Side Functional Module)

  • 신덕호;이재훈;이기서
    • 한국철도학회논문집
    • /
    • 제8권2호
    • /
    • pp.170-175
    • /
    • 2005
  • This study presents a prediction of a failure rate in a safety required system that consists of a embedded control system, requiring a satisfaction of a quantitative safety requirement. International Standards are employed to achieve a regular procedures in the whole life cycle of a system, for the purpose of a prediction and a evaluation of a fault that might be able to be happened in a system. This International Standards uses SIL (Safety Integrity Level) to evaluate a safety level of a system. SIL is divided into 4 levels, from level 1 to level 4, and each level has functional failure rate and dangerous failure rate of a system. In this paper we describe the conventional method to predict the dangerous failure rate and propose a method using hazard analysis to predict the dangerous failure rate. The conventional method and the technique using hazard analysis to predict the dangerous failure rate are made a comparison through the control modules of the interlocking system in KTX. The proposed method verify better effectiveness for the prediction of the dangerous failure rate than that of the conventional method.

하이브리드형 전기식 제동장치의 성능에 대한 연구 (A Study on the Performances of Hybrid type Electric Brake System)

  • 송정훈;부광석;임철기
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1492-1498
    • /
    • 2003
  • This study proposes a new conceptual Hybrid Electric Brake System (HEBS) which overcomes problems of a conventional hydraulic brake system. HEBS adopt a contactless type bake system when a vehicle speed is high, to obtain superior braking performances by eddy current. On the contrary, when a vehicle speed is low, HEBS employs a contact type brake system such as conventional hydraulic brake system to generate higher brake force. Therefore, HEBS transfers faster the braking intention of drivers and guarantees the safety of drivers. Braking torque analysis is performed by using a mathematical model which is proposed to investigate the characteristic of a vehicle dynamics when the brake torque is applied. Optimal torque control is achieved by maintaining a desired slip corresponding to the road condition. The results show that HEBS reduces the stopping distance, saves the electric energy, and increases the stability.

Design and Control of an Optimized Battery Charger for an xEV Based on Photovoltaic Power Systems

  • Kim, Dong-Hee;Cheo, Gyu-Yeong;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1602-1613
    • /
    • 2014
  • The continuous growth of electric vehicles has caused electric power shortages in conventional utilities owing to the charging of electric-vehicle batteries. In order to increase the capacity of these utilities, photovoltaic systems may be an appropriate solution because of their benefits. However, a large amount of loss is generated in a conventional charging structure using photovoltaic sources owing to the many power conversion processes. This paper describes a simple integrated battery charger that utilizes a PV generation system. Moreover, the system control algorithm is deduced by analyzing the operation modes in order to control the proposed integrated system. The proposed system and algorithm are verified by a 3.3-kW prototype, resulting in an increase in the efficiency of approximately 7% to 15% compared with the conventional system. And, to examine the feasibility of the proposed system, the simulation for multi-charger with various conditions are progressed.

Characteristics of Rice and Paddy Soil under No-Till Direct-Sown Rice-Wheat Cropping System

  • Cho, Young-Son;Choe, Zhin-Ryong;Lee, Byeong-Zhin
    • 한국유기농업학회지
    • /
    • 제7권2호
    • /
    • pp.153-161
    • /
    • 1999
  • No-till direct-sown rice-wheat relaying cropping system has major advantages such as labor and cost saving by eliminating tillage and preparation of seed bed and transplanting. In this system, rice sowing was done simultaneously wheat harvesting. A paddy field experiment was conducted to evaluate effects of no-till years on soil microbial changes and soil physico-chemical characteristics with rice growth and development. Chemical fertilizers and agricultrual chemicals was not applied in no-till system. As the year in no-till direct-sown system the air permeability was increased and after water submerging soluble nitrogen was released Aerobic microbial-n was highest in May and then decreased after water irrigation. The population of aerobic soil microorganisms were steeply decreased after water submerging Soil microorganisms was decreased with the increased the soil depth. A month was needed for the seedling establishment in a no-tillage rice-wheat cropping system. Increased cropping years improved leaf greenness and leaf area index(LAI). But stomatal conductance(Gc) was higher in conventional cultivation system than no-till system. Stomatal conductance at panicle initiation stage was increased higher in conventional condition of leaves but the difference between conventional and no-till system was increased at heading stage. In no-till 4 years condition rice grain yield was spikelet numbers per panicle.

  • PDF

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

현재 상태 추정기를 이용한 멀티레이트 제어에 관한 연구 (A Study on Multirate Control Using a Current Estimator)

  • 황희철;정정주;정동실
    • 제어로봇시스템학회논문지
    • /
    • 제8권12호
    • /
    • pp.1004-1013
    • /
    • 2002
  • A multirate state feedback control (MRSFC) method is proposed for systems sensitive to disturbance and noise based on the multirate estimator design using current estimator. MRSFC updates the controller output slower than the measurement sampling fiequency of system output by a lifting factor $R=T_c/T_s$ The closed-loop MRSFC system is less sensitive to disturbance and noise due to filtering effect than the conventional single-rate control system The multirate estimator gain can be obtained by solving a conventional pole placement problem such that MRSFC has the same spectrum of eigenvalues in the s-plane as the single-rate control. We applied the proposed multirate state feedback controller to a galvanometer servo system Simulation and experimental results show that settling and tracking performances are improved compared with a conventional single-rate pole placement control (PPC).

Headway Comparison between ATS and ERTMS/ETCS system

  • Kim, Y.K.;Lee, Y.H.;Ryu, C.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1333-1337
    • /
    • 2003
  • The present headway on KNR lines varies from 6 to 10 minutes. Therefore, KNR would like to reduce the headway of all the lines by 4 minutes with the implementation of ERTMS/ETCS on-board system. In Korea, thanks to the operation of the High Speed Line in 2004, the bottleneck phenomenon will occur only in a few sections such as Seoul-Siheung, which will be the common route between KTX and conventional trains. Therefore, we will analyze expected braking distance and running time depending on characteristics of conventional passenger and freight trains and high speed train will be operated within electrified conventional line for comparing the headways of ATS trackside and ETRMS/ETCS on-board system within the Seoul-Siheung section.

  • PDF

Dithering기법에 의한 직접 토크 제어 방식의 토크리플 개선에 관한 연구 (A study on the torque ripple reduction of PMSM in direct torque control by using dither signal)

  • 이홍희;김정현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.415-419
    • /
    • 2003
  • This paper focuses on a simple technique to reduced torque ripple in the direct torque control inverter for PMSM drive. It is actually impossible to raise the inverter switching frequency in the conventional system, although the hysterisis bandwidths for the stator flux and torque control are sufficiently diminished, because of the sampling Interval and the delay in estimating the flux and the torque In order to overcome the problem, the proposed method introduces a dithering technique into the conventional system by superposing triangular waves with high frequency and minute amplitude on the torque error. And the programable 3- stage lowpass filter is added instead of pure Integrator. Simulation results prove the feasibility of proposed strategy compared with conventional method.

  • PDF