• Title/Summary/Keyword: Conventional system

Search Result 14,428, Processing Time 0.042 seconds

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

A Turbo Processing MIMO System with Non-Linear MMSE Detector for High-Speed Wireless Communications (고속 무선 통신을 위한 비선형 MMSE 검출기를 갖는 터보 처리 다중 입출력 시스템)

  • Kang, Byeong-Gwon;Cho, Dong-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1164-1171
    • /
    • 2006
  • In this paper, a simple and nonlinear MMSE detector is derived from the conventional linear MMSE detector to improve the system performance in turbo processing MIMO system and a new turbo processing MIMO system with nonlinear MMSE detector and Gaussian approximation is proposed. In turbo coded turbo processing MIMO system, the proposed system of M=N=4 performs about 0.5 dB better than the conventional system and the proposed system of M=N=8 performs about 0.4 dB better than conventional system at 1 % FER. In addition, the average number of outer iterations of proposed system shows lower than that of conventional system. This is caused by the fact that the nonlinear MMSE detector of proposed system decides soft-outputs of coded bits based on the observation of received signals, so that it can reduce the uncertainty region in estimating the coded bits.

Stereo Image Insertion using Alteration of DCT Coefficients of Color Channels (칼라채널의 DCT 계수 변경을 이용한 스테레오 영상 삽입)

  • 이호근;천성렬;하영호
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.175-178
    • /
    • 2003
  • This paper proposes a stereo image insertion technique on DCT coefficients using the embedded method developed in the digital watermarking in due consideration of compatibility with conventional 2D system such JPEG, and MPEG. In conventional transmission method users with conventional digital TV cannot watch the transmitted 3D image sequence as 2D image, because of affectivity of conventional 3D image compression. To give an answer, in this paper, DCT coefficients are changed according to its disparity on YCbCr channels. Our method can insert stereo images into a conventional image compression method based on DCT.

  • PDF

A Study on Design Parameters of Dual Mass Flywheel System (Dual Mass Flywheel 시스템의 설계 파라미터에 관한 연구)

  • 송준혁;홍동표;양성모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.90-98
    • /
    • 1998
  • A Dual Mass Flywheel(D.M.F.) system is an evolution to the reduction of torsional vibration and impact noise occurring in powertrain when a vehicle is either moving or idling. The D.M.F. system has two flywh-eels, which is different from the conventional clutch system. One section belongs to the mass moment of in-ertia of the engine-side. The other section increases the mass moment of inertia of the transmission-side. These two masses are connected via a spring/damping system. This reduces the speed at which the dreaded resonance occurs to below idle speed. Since 1984m D.M.F. system has been developed. However, the processes of development of D.M.F. system don't have any difference from the trial and error method of conventional clutch system. This paper present the method for systematical design of D.M.F. system with dimensionless design varia-bles of D.M.F. system, mass ratio between two flywheels, natural frequency rate of two flywheels, and visc-osity coefficient. And expermental results are used to prove these theoretical results.

  • PDF

An Experimental Study on the Performance Characteristics of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank (축냉시스템을 이용한 냉매과냉각형 냉동시스템의 성능특성에 관한 실험적 연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.369-374
    • /
    • 2010
  • A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat exchange between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The performance of the refrigerant-subcooling refrigeration system was measured by varying the degree of subcooling. In addition, the performance characteristics of the present system were compared with those of a conventional refrigeration system. The mass flow rate of the present system was higher than that of the conventional system due to the increase in the degree of subcooling. Generally, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system.

Experimental Studies on the Stack Cooling Performance Using a $CO_2$ Air Conditioning System in Fuel Cell Vehicles (이산화탄소 에어컨 시스템을 이용한 연료전지 자동차의 스택 냉각성능에 대한 실험적 연구)

  • Kim, Sung-Chul;Kim, Min-Soo;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.87-93
    • /
    • 2008
  • The $CO_2$ air conditioning system installed in fuel cell vehicles could be used either for stack cooling or for cabin cooling, and thus was used for the stack cooling when additional stack heat release was required over a fixed radiator capacity for high power generation. This study investigated the performance of the stack cooling system using $CO_2$ air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed for the stack cooling system using an air conditioner and compared with the conventional radiator cooling system with/without cabin cooling. The heat release of the stack cooling system with the aid of $CO_2$ air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, the heat release of the stack cooling system using $CO_2$ air conditioner increased more by 7% than that of the conventional radiator cooling system without cabin cooling.

The establishment of Digital Image Capture System(DICS) using conventional simulator (Conventional simulator를 이용한 Digital image capture system(DICS)의 구축)

  • Oh Taesung;Park Jongil;Byun Youngsik;Shin HyunKyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, flouroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and flouroscopic image. Methods and materials : We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record flouroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) Result : DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Conclusion : Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  • PDF

Investigation of Effective Maintenance System for the Infra on the Conventional Line Prepared for the Tilting Train Service (틸팅열차 상용화대비 기존선 인프라시스템의 효율적 유지보수체계 검토)

  • Yoo, Keun-Su;Lee, Chang-Hun;An, Gang-Yell;Kim, Joung-Tea
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.79-87
    • /
    • 2008
  • The major objective of this study is to investigate the effective maintenance system for the infrastructure on the conventional lines in which the tilting train runs. In order to the speed-up of conventional lines that have many curve lines, there needs a improvement construction of substructure such as the straight or double track work and so on. But in this case, it needs to have a plenty of the cost and the period. Therefore, the tilting train which provides the high-speed service effectively in curve tracks was developed. Besides, the efficiency prediction and the linear fitness of the existing conventional lines for a tiling train service were examined on the preceding study which was the development of track system innovation technology for speed-up of them. So, in this paper we propose the more effective maintenance method than the existing it in order to securing the high reliability and safety classified by the infrastructure, in analyzing foreign materials and the maintenance as well as the inspection cycle concerning domestic infrastructures of the track and the catenary etc. on the railway. And we look forward to playing a decisive role as reference material for the effective improvement of the existing maintenance about the infra on the conventional lines for the commercial service of the tilting train.

  • PDF

Evaluation of the Common-management Foodservice System of the Elementary Schools in Kyungbook Region (경상북도 지역 국민학교 공동관리 급식 실태 및 영양사 직무만족도 평가)

  • 이혜상
    • Korean journal of food and cookery science
    • /
    • v.11 no.4
    • /
    • pp.370-378
    • /
    • 1995
  • This study is to seek methods for optimum management of foodservice system for elementary schools in Korea through surveying and analyzing the current status of the "common-management foodservice system" and certain important factors relating to its operations. For the survey of the current status of the "common-management foodservice system", questionnaires are prepared as against schools adopting "common-management system"("Common Schools") as well as schools adopting "conventional management system" ("Conventional Schools") in Kyungsangbookdo ("Kyungbook") area. The survey items are composed of general items, items concerning tasks of dietitians, items concerning purchasing activities and items concerning level of recognition and job-satisfaction of the dietitians. Total 46 dietitians from Common Schools and 65 dietitians from Conventional Schools in Kyungbook region responded the questionnaires. The results of this study are as follows: 1. Information Concerning Dietitians Average age of the dietitians: 26.6 yrs Ratio of two years or less of experiences as school dietitian: Dietitians from Common Schools: 59.1% Dietitians from Conventional Schools: 50.8% 2. Types of the Foodservice In both schools, rural type are prevalent; however, between urban types and islands types, the ratio of urban types are larger than the ratio of islands types in Conventional Schools, and the opposite is true in Common Schools. 3. Decision of Suppliers The ratio of dietitian's participaion in the decision making reaches only 38.3%, indicating the possibility of problems in quality control and hygienic aspects of the food supply. 4. Factor Analysis of the Foodservice Duties Food supply and general affairs administration work was carried out very well (4.2), while personnel management and operational improvement work (2.8), nutritional education work (2.3), and information related work were poorly carried out. No significant differences were found between the two types of the foodservice management systems. 5. Job Satisfaction scores of Dietitians Dietitians were more satisfied with the works (50.0), supervision (50.5) and co-workers (46.9) than pay (18.0) and promotion (22.3).

  • PDF