• 제목/요약/키워드: Conventional coil

검색결과 290건 처리시간 0.034초

고압전동기 모델 코일의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Model Coils)

  • 김희동;공태식;김병래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1612-1614
    • /
    • 2003
  • 80pF capacitive couplers were connected to six 6.6kV motor model coil terminals. The voltage applied to the coils were 3.81kv, 4.76 kV and 6.6kV, respectively. These stator coils have various types of artificial insulation defects such as large voids, semi-conductive coating damage and strand insulation fault. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in PD were measured with a conventional digital PD detector. Most of the defect mechanism of large motor stator winding can be associated with PD patterns such as internal and slot discharges. PD patterns coincide with PDD and TGA. These instruments have an input bandwidth of 40-400kHz and 0.1-350MHz. Surge testing detects faults in inter-turn winding of high voltage motor model coils.

  • PDF

할바 자석배열을 이용한 초소형 정보저장장치의 초점 구동기 설계 (Halbach Array Type Focusing Actuator for Small and Thin Optical Data Storage Device)

  • 이성규;박강호;백문철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.65-69
    • /
    • 2004
  • The small form factor optical data storage devices are developing rapidly nowadays. Since it is designed for portable and compatibility with flash memory, its components such as disk, head, focusing actuator, and spindle motor should be assembled within 5 m thickness. The thickness of focusing actuator is within 2 mm and the total working range is $+/-100{\mu}m$, with the resolution of less than $1{\mu}m$. Since the thickness is limited tightly, it is hard to place the yoke that closes the magnetic circuit and hard to make strong flux density without yoke. Therefore, Halbach array is adopted to increase the magnetic flux of one side without yoke. The proposed Halbach array type focusing actuator has the advantage of thin actuation structure with sacrificing less flux density than conventional magnetic array. The optical head unit is moved on the swing arm type tracking actuator. Focusing coil is attached to swing arm, and Halbach magnet array is positioned at the bottom of deck along the tracking line, and focusing actuator exerts force by the Fleming's left hand rule. The working range and resolution of focusing actuator are analyzed with FEM and experiment.

  • PDF

Construction of 19F-13C Solid-State NMR Probe for 400MHz Wide-Bore Magnet

  • Jeong, Ji-Ho;Park, Yu-Geun;Choi, Sung-Sub;Kim, Yongae
    • 한국자기공명학회논문지
    • /
    • 제17권2호
    • /
    • pp.81-85
    • /
    • 2013
  • Various fluorine-containing materials are used in electronic devices like LCD display panels and Li-ion batteries. The structural conformation of fluorine in fluorinated materials is an important contributing factor that influences the chemical and physical properties. The conformation can be changed by heat and stress during manufacture or use. Understanding the conformational changes is critical for understanding the performance and durability of electronic devices. Solid-state NMR spectroscopy could be widely used for the analysis of various fluorine-containing materials for electronic devices. However, conventional CPMAS probes cannot be used for in-situ analysis of fluorine-containing electronic devices like LCD panels and Li-ion batteries. In this paper, we show the design, construction, and optimization of a $^{19}F-^{13}C$ double-resonance solid-state NMR probe for a 400MHz wide-bore magnet with a flat square coil for in-situ analysis of fluorine-containing electronic devices without observing fluorine background signals. This custom-built probe does not show any fluorine background signals, and can have higher efficiency for lossy samples.

Fabrication and statistical characterization of Nb SQUID sensors for multichannel SQUID system

  • Kim, B.K.;Yu, K.K.;Kim, J.M.;Kwon, H.;Lee, S.K.;Lee, Y.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.62-66
    • /
    • 2020
  • We fabricated superconducting quantum interference devices (SQUIDs) based on Nb Josephson junctions, and characterized the key parameters of the SQUIDs. The SQUIDs are double relaxation oscillation SQUIDs (DROSs) having larger flux-to-voltage transfer coefficient than the standard DC-SQUIDs. SQUID sensors were fabricated by using Nb junction technology consisted of a DC magnetron sputtering and a conventional photolithography process. In multichannel SQUID systems for whole-head magnetoencephalography measurement with a helmet-type SQUID array, we need about 336 SQUID sensors for each system. In this paper, we fabricated a few hundred SQUID sensors, measured the critical current, flux modulation voltage and decided if each tested SQUID can be used for the multichannel systems. As the criterion for the acceptance of the sensors, we chose the critical current and amplitude of the modulation voltage to be 8 ㎂ and 80 ㎶, respectively. The average critical current of the SQUIDs was 10.58 ㎂. The typical flux noise of the SQUIDs with input coil shorted was 2 μΦ0/√Hz at white region.

Pt포일 양극을 이용한 전기화학적 암모니아 수전해 특성 연구 (Characterization of Electrochemical Ammonia Electrolysis Using a Platinum Electrode for Anodic Reaction)

  • 최정민;김학덕;송주헌
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.337-342
    • /
    • 2022
  • In this study, a water electrolysis was studied to investigate the effect of ammonia on current density and H2 gas production. A H type cell with three electrodes was used and KOH solution was used as electrolyte. The conventional platinum foil was used for working electrode, whereas nickel foam was used for counter electrode. CV experiment was performed to see the activity of ammonia oxidation reaction. In addition, CP experiment was done to examine the dependence of Faraday efficiency of hydrogen on current density and NH3 concentration. The CV result shows the 0.5M NH3 concentration required for highest current density and reliable operation. The CP result shows the increased current density leads to higher H2 generation. The higher H2 production and subsequent energy efficiency was observed for 0.5M NH3 using a Pt/13%Rh coil for a cathode as compared to those in water electrolysis.

1MW급 고온초전도 동기기의 전자기적 특성 해석 (Analysis of Electromagnetic Characteristics of a 1MW Class HTS Synchronous Motor)

  • 백승규;권영길;이언용;이재득;김영춘;문태선;박희주;권운식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.32-36
    • /
    • 2007
  • On the contrary of a conventional motor with very narrow air-gap. it is difficult to calculate the accurate magnetic field distribution and the performance of an air-cored superconducting motor by 2 dimensional analysis. which does not use high permeability material except outer machine shield. This paper aims to do analysis of magnetic field and force distribution from the 3 dimensional modelling of a 1MW class superconducting synchronous motor. Especially. the field coil composed of Bi-2223 high-temperature superconductor and the outer machine shield are modelled by finite element analysis software according to their structures and the self-inductance and Lorentz force are calculated based on the 3 dimensional magnetic field calculation. Moreover. the influence of an important parameter, synchronous reactance, has been analyzed on the machine performances such as voltage variation and output power.

유기물 바인더를 사용한 $YBa_2Cu_3O_{7-{\delta}}$ 초전도 Coil의 제조 (Fabrication of $YBa_2Cu_3O_{7-{\delta}}$ Superconducting Coils with Polymer Binder)

  • 정해원;박승만;김재묵;김성수
    • 한국세라믹학회지
    • /
    • 제27권3호
    • /
    • pp.355-360
    • /
    • 1990
  • One of the possible ways to make a flexible wire of high-Tc superconductiong ceramics is the extrusion of a mixture slurry of superconducting powder with an appropriate polymer binder. The fabrication procedure for $YBa_2Cu_3O_{7-{\delta}}$ superconducting coils with this plastic mass is described. The major factors limiting the formation of extruded wire are the binder content, powder size, and entrapped gas in the mixture slurries. The optimum content of binder for both good flexbility and strength of wire was estimated to be 30wt%. The finer the powder size is, the more homogeneous structure the extruded wire has. The vacuum degassing before extrusion was necessary to remove the entrapped gas in as-extruded wire. The formability of wire depends greatly on the wire radius and binder content. After burning out the binder and the successive sintering, the contacts between the superconducting grains could be made. The resistivity vs. temperature behavior measured in the final wire showed the transition temperature of 90K with narrow transition width. However, the critical current densities of these wires are much lower in comparison to those of conventional bulk specimens.

  • PDF

소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용 (Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.64-72
    • /
    • 2002
  • 목적 : 소아 뇌 질환에서의 자기공명분광법의 임상적 적용에 있어서 단일화적소 양성자 자기공명분광법과 고식적 이차원 양성자 자기공명분광법에 비해 혼성 이차원 양성자 자기공명분광법이 가지는 장점에 대하여 알아보고자 하였다. 대상 및 방법 : 생후 3일에서 15세까지의 79명의 소아 (정상소아 36명, 저산소성-허혈성 뇌 손상 10명, 대사성 질환 20명, 뇌막염-뇌염 3명, 뇌종양 7명, 신경섬유종증 1명, Sturge-Weber 증후군 1명, lissencephaly 1명)를 대상으로 81회의 혼성 이차원 양성자 자기공명분광검사를 시행하였다. 성인자원자(n=5)에서 단일화적소 양성자 자기공명분광법, 고식적 이차원 양성자 자기공명분광법, 그리고 혼성 이차원 양성자 자기공명분광법 모두를 실시하였고, 환아군 중 일부(n=12)에서 PRESS기법을 이용한 단일화적소 분광법과 혼성 이차원 양성자 자기공명 분광법을 함께 시행하였다. 1.5-T 초전도영상장치 하에서 standard head quatrature coil을 이용하여 양성자 자기공명분광을 얻었다. Phase encoding step은 16$\times$16으로 하였고, FOV는 환자 뇌의 크기에 따라 다양하게 하였으며, FOV내의 혼성 관심 체적 (hybrid VOI)은 $75{\times}75{\times}15{\;}\textrm{mm}^3$ 또는 그 이하로 함으로써 원하지 않는 지방에 의한 신호를 없애도록 하였다. PRESS기법 (TR/TE= 1,500 msec/135 또는 270 msec)을 적용하였고, 물에 의한 신호를 억제하기 위하여 chemical shift selective saturation pulse를 사용하였다. 혼성 이차원 양성자 자기공명분광검사의 획득시간(data acquistion time)과 분광의 질(spectral quality)을 단일화적소 양성자 자기공명분광법과 고식적이차원양성자 자기공명분광법의 그것과 비교하였다. 결과: 혼성 이차원 양성자 자기공명분광법은 79명의 소아 전 예에서 성공적으로 시행되었다. 단일화적소 양성자 자기공명분광법의 획득시간은 4.3분인 반면에, 혼성 이차원 양성자 자기공명분광법의 획득시간(data acquition time)은 6분 미만으로, 이는 소아의 뇌영상용으로 쓰기에 충분히 짧은 소요시간이었다. 혼성 이차원 양성자 자기공명분광법에 의한 분광은 단일화적소 자기공명분광법에 의한 분광과 거의 비슷한 민감도와 분광분해 능을 나타내었으며, 반면에 고식적인 이차원 양성자 자기공명분광법에 의한 분광보다는 훨씬 우수하였다.

  • PDF

NFC 와 WPC 복합기능의 삽입형 안테나 복합체 개발 (Development of embedded type antenna structure with NFC and WPC complex function)

  • 박노국;이덕수;장정선
    • Journal of Platform Technology
    • /
    • 제6권4호
    • /
    • pp.59-68
    • /
    • 2018
  • 본 연구는 NFC와 WPC복합기능의 삽입형 안테나 구조체를 개발하기 위한 것이며, 안정성이 확보된 재료를 선택하여 폴리머시트의 최적의 성분비를 도출하였고 기존 FPCB 대비 저가의 임베디드 권선방법을 고안하여 폴리머시트에 직접권선을 하는 과정에서 특성평가 및 공정기술을 개발하였다. 또한 페라이트 금형을 제작하여 WPC홈을 가공하고 WPC안테나의 최적화를 위한 공정기술개발을 배양하였으며 다음과 같은 결론을 얻었다. (1) 폴리머시트의 원재료는 Fe-Si-Al로 구성되어 있으며 NFC와 WPC복합기능의 폴리머시트로 적용하기 위한 최적의 성분비를 Fe 87.5%, Si 7%, Al 5.5%로 도출하여 최종재료로 선택하였다. (2) 최적화된 시트와 기존 양산되는 FPCB와의 조합테스트를 통해서 실험평가방법 및 실험계획법에 의한 최적의 시트조건을 도출하였다. (3) 코일의 선경 및 내경의 크기에 따라서 Q값 변동과 저항값 및 효율변동이 되므로 가장 적합한 코일의 조건을 선정하여 Rx매칭을 할 수 있었으며 코일의 선경을 선택하는 실험과정에서 공정개발능력을 배양하였다.(4) 최적화된 시트와 임베디드와의 최적화 도출 및 평가를 위해서 폴리머시트와 페라이트시트의 EMV load modulation test 및 인지거리 테스트 결과 1k 및 4K에서 폴리머시트의 인식거리가 32-33mm가 형성되었고 동일조건의 페라이트시트의 인식거리는 30-31mm가 형성되었다.

The Effects of Repetitive Transcranial Magnetic Stimulation on Balance Ability in Acute Stroke Patients

  • Ji, Sang-Goo;Shin, Young-Jun;Kim, Myoung-Kwon
    • 대한물리의학회지
    • /
    • 제11권3호
    • /
    • pp.11-17
    • /
    • 2016
  • PURPOSE: The aim of the present study was to determine whether high frequency repetitive transcranial magnetic stimulation (rTMS) can improve balance ability in acute stage stroke patients. METHODS: The study was conducted on 30 subjects diagnosed with hemiparesis caused by stroke. The experimental group consisted of 15 patients that underwent rTMS for 15 mins and the control group consisted of 15 patients that underwent sham rTMS (for 15 minutes). A 70-mm figure 8 coil and a Magstim Rapid stimulator was used in both groups. Patients in the experimental group received 10 Hz rTMS applied to the hotspot in the lesioned hemisphere in 10-second trains with 50-second intervals between trains, for 15 minutes (total 2,000 pulses). Both groups received conventional physical therapy for 30 minutes a day, 5 days a week, for 4 weeks. Static balance ability analysis was performed using the Gaitview system to measure pressure rate, postural sway, and total pressure, and dynamic balance ability analysis was performed to measure pressure variables using a balance system. RESULTS: A significant difference was observed in post-training gains for pressure rate, total pressure in static balance, and overall stability index in dynamic balance between the experimental group and the control group (p<.05). CONCLUSION: The results of this study indicate that high frequency rTMS may be beneficial for improving static and dynamic balance recovery in acute stroke patients.