• Title/Summary/Keyword: Convenient Measurement

Search Result 328, Processing Time 0.024 seconds

Development of Light Transmission Fluctuation for Particle Measurement in Solid-Gas Two Phase Flows

  • YANG, Bin;WANG, Zhan-ping;HE, Yuan;CAI, Xiao-Shu
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • In order to realize In-line and convenient measurement for solid-gas two phase flows, Light Transmission Fluctuation (LTF) based on the random variation of transmitted light intensity, light scattering theory and cross-correlation method was presented for online measurement of particle size, concentration and velocity. The statistical relationship among transmitted light intensity, particle size and particle number in measurement zone was described by Beer-Lambert Law. Accordingly, the particle size and concentration were determined from the fluctuation signal of transmitted light intensity. Simultaneously, the particle velocity was calculated by cross-correlation analysis of two neighboring light beams. By considering the influence of concentration variation in industrial applications, the improved algorithm based on spectral analysis of transmitted light intensity was proposed to improve measurement accuracy and stability. Therefore, the online measurement system based on LTF was developed and applied to measure pulverized coal in power station and raw material in cement plant. The particle size, concentration and velocity of powder were monitored in real-time. It can provide important references for optimal control, energy saving and emission reduction of energy-intensive industries.

Stress-Sensors with High-Sensitivity Using the Combined Meandering-Patterns

  • Cho, Chun-Hyung;Cha, Ho-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • In this work, the combined meandering-pattern stress-sensors were presented in order to achieve the high sensitivity of stress sensors. Compared to the previous works, which have been using the single meandering-pattern stress-sensors, the sensitivity was approximately observed to increase by 30%~70%. Also, in this paper, more simple and convenient stress-measurement method was presented.

Exploring an Instrumental Measurement of Quality of Housing Environment (주거환경의 질 척도에 관한 연구)

  • 박정희
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.71-84
    • /
    • 1994
  • This article tries to develop an instrument for assessing the quality of housing environment by using 67 housing environment variables. The method of factor analysis is used to explore the dimension of the quality of housing. As the result, 5 dimensions of housing environment are extracted. They are, according to the order of their importances, house structure and indoor environment, outdoor facilities and natural environment, indoor facilities and economy, public facilities and social relationship, and convenient facilities and residential feasibility.

  • PDF

Why Standard Measures of Human Capital are Misleading

  • HANUSHEK, ERIC A.
    • KDI Journal of Economic Policy
    • /
    • v.37 no.2
    • /
    • pp.22-39
    • /
    • 2015
  • After a long, dormant period, recent attention has turned to a variety of measurement issues surrounding the concept of human capital. The traditional approach of rely entirely on measures of school attainment, while convenient, is almost certainly misleading. The availability of cognitive skills measures greatly improves on these measurements, but there remains also concern about other unmeasured factors, including noncognitive skills. This paper considers alternative approaches to assessing the role of human capital on individual earnings and on economic growth.

  • PDF

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

Fixed Point Algorithm for GPS Measurement Solution (GPS 관측치 위치계산을 위한 부동점 알고리즘)

  • Lim, Samsung
    • Journal of Advanced Navigation Technology
    • /
    • v.4 no.1
    • /
    • pp.45-49
    • /
    • 2000
  • A GPS measurement solution, in general, is obtained as a least squares solution since the measurement includes errors such as clock errors, ionospheric and tropospheric delays, multipath effect etc. Because of the nonlinearity of the measurement equation, we utilize the nonlinear Newton algorithm to obtain a least squares solution, or mostly, use its linearized algorithm which is more convenient and effective. In this study we developed a fixed point algorithm and proved its availability to replace the nonlinear Newton algorithm and the linearized algorithm. A nonlinear Newton algorithm and a linearized algorithm have the advantage of fast convergence, while their initial values have to be near the unknown solution. On the contrary, the fixed point algorithm provides more reliable but slower convergence even if the initial values are quite far from the solution. Therefore, two types of algorithms may be combined to achieve better performance.

  • PDF

The Experience in Dose Measurement of IVR with Glass Dosimeter System

  • Nishizawa, Kanae;Moritake, Takashi;Iwai, Kazuo;Matsumaru, Yuji;Tsuboi, Koji;Maruyama, Takashi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.269-271
    • /
    • 2002
  • It is reported that exposure for the patient and the medical staff from IVR is large. Direct measurement of patient exposure is difficult, since the measurement disturbs reading of images. The fluorescence glass-dosimeter system consisting of small-size glass chips is developed in recent years. Owing to its small size and physical characteristics, direct monitoring of surface dose may be feasible. The dose measurement for patient and medical staff during head interventional radiology (IVR) examinations was tried by using the fluorescence glass-dosimeter system. A dose response of the glass dosimeter is almost linear in large dose range but its energy dependency is high. About 20% variation of sensitivity was observed in the effective energy of 45-60keV which was used in IVR. In spite of this shortcoming, the fluorescence glass-dosimeter system is a convenient means for a dose monitoring during IVR performance.

  • PDF

A study on the method of measurement of the standing-tree volume -Particularly concerning the method of measurement of the timber volume (입목재적(立木材積) 측정법(測定法)에 관(關)한 연구(硏究) -용재수목(用材樹木)의 재적측정법(材積測定法)을 중심으로)

  • Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.3 no.1
    • /
    • pp.28-31
    • /
    • 1963
  • Recognizing shortcomings and unreasonable points of the usual methods of measurement of the standing-tree volume, author contrived measurement formula of standing-tree volume which is based on stem-curve equation, $y^2=2px$, resulted from the analysises and experiments on stem-curve by differentiation & integration. The results of this study are as follows ; (1) The following is the formula. $V=1/2g_{1.2}$(h+1.2) V=volume of tree $g_{1.2}$ = sectional area at breast heigh h = height of tree (2) So plain is the form of this formula that this formula is more convenient than usual formulas in measuring. (3) The percentage error of this formula is negative and it is remarkably superior to usual formulas except Pressler's formula, in other words, the higher the tree that is measured is, the more inaccurate become pressler's formula, and the percentage error of the breast-height form factor method is direct proportion to the grossness of the tree that is measured, but the higher the tree that is measured, the lower become percentage error of this formula in geometrical progression.

  • PDF

A Comparative Study of Oswestry Back Pain Disability Questionnaire Versus Computer Adaptive Testing for Measuring Back Pain

  • Choi, Bong-Sam
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.22-31
    • /
    • 2013
  • The aim of the present study was to compare measurement precisions of the Oswestry Back Pain Disability Questionnaire (ODQ) and a computer adaptive testing (CAT) method. The ODQ has been regarded as one of the most reliable condition-specific measure for back pain for decades. Cross-sectional study was carried out with two independent convenient samples from two out-patient rehabilitation clinics for back pain ($n_1=42$) and non-back pain group ($n_2=42$). Participants were asked to fill out the ODQ and CAT of International Classification of Functioning, Disability and Health-Activity Measure (ICF-AM). A series of Rasch analyses were performed to calculate person ability measures. The CAT measures had greater relative precision in discriminating the groups than did the ODQ measure in comparisons of the relative precision. The CAT measure appears to be more effective than did the ODQ measure in terms of measurement precision. By administering test items calibrated in a way, CAT measures using item response theory may promise a means with measurement precision as well as efficiency.

Development of a Sensor System to Measure Real Time Vibro Displacement of Civil Structure (레이저 센서를 이용한 구조물의 변위 측정 장비 개발)

  • O, Heung-Il;Kim, Hui-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.823-825
    • /
    • 2003
  • A sensor system was designed to measure real time vibro displacement of civil structure. The He-Ne laser is used for the displacement measuring method, because it guarantees short time stabilization, long time output power stability. Also, it guarantees simple maintenances and repairs under actual using condition. The line CCD image sensor(Tcd-142d) is used to detect the displacement of Ne-Ne laser responding to the vibro of civil structure. For accurate measurement and comparison, CDP-50 is used. Usually CDF-50 (Strain type displacement device) is used for the standard correction device of optical measurement equipments. The data processing part is consists of Optical sensor part, Wireless data transmission device, DAQp-1200, and LapView program. The displacement data of vibro from optical sensor part inputted to wireless data transmission device and then transmitted to DAQp-1200 in main control room. DAQp-1200 performs A/D conversion for the receiving data. After that the converted data inputted to computer system using LapView program for user display. The significance of this paper is to develope a convenient, accurate and lost saving real time displacement measurement system for the civil structure.

  • PDF