• 제목/요약/키워드: Convective heat transfer coefficients

검색결과 124건 처리시간 0.018초

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

대체냉매 관내 열전달특성 시험을 위한 동심이중원관의 환상유로의 열전달계수 (Heat Transfer Coefficients of Concentric Annuli for Testing Heat Transfer Characteristics of Alternative Refrigerants in Tubes)

  • 김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제32권1호
    • /
    • pp.63-67
    • /
    • 2021
  • Accurate measurements of the heat transfer coefficients of concentric annular space for the test section is important to measure the tube-side heat transfer coefficients of working fluids. This paper presents the annular side heat transfer coefficients of concentric annuli with variation of tube diameter ratios using Wilson plot method. The test facility has a straight, horizontal test section with an active length of 3.0 m. Inner/outer diameters of test tubes are 7.0/7.5 and 8.0/8.56 mm, respectively. An outer diameter of annulus side is 16.0 mm. The test results show that convective heat transfer coefficients in annuli increase with annular diameter ratio. The correlations for convective heat transfer coefficients in annuli are also developed.

비비등 선회유동에서의 2상 대류열전달 증가 (Two phase convective heat transfer augmentation in swirl flow with non-boiling)

  • 차경옥;김재근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2586-2594
    • /
    • 1995
  • Two phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and various heat exchangers. This experimental study has been investigated the classification of the flow pattern, the local void distribution and convective heat transfer in swirl and non-swirl two phase flow under the isothermal and nonisothermal conditions. The convective heat transfer coefficients in the single phase water flow were measured and compared with the calculated results from the Sieder-Tate correlation. These coefficients were used for comparisons with the two-phase heat transfer coefficients in the flow orientations. The experimental results indicate, that the void probe signal and probability density function of void distribution can used into classify the flow patterns, no significant difference in voidage distribution was observed between isothermal and non-isothermal condition in non-swirl flow, the values of two phase heat transfer coefficients increase when superficial air velocities increase, and the enhancement of the values is observed to be most pronounced at the highest superficial water velocity in non-swirl flow. Also two phase heat transfer coefficients in swirl flow are increased when the twist ratios are decreased.

옵셋 스트립 휜의 휜피치가 고 Prandtl 유체 열전달 특성에 미치는 영향 (A Study on the Effect of Fin Pitch of Offsets Strip Fin on Heat Transfer of High Prandtl Fluid)

  • 강덕종;양대일;전승환;정형호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.83-89
    • /
    • 2002
  • In the present study, heat transfer characteristics of oil flow over offset strip fins were predicted by the numerical methods. Oil flow in the plate-fin passage was idealized by 2 dimensions. The flow patterns and heat transfer characteristics were predicted in details. Numerical results shows that the average convective heat transfer coefficients are almost independent on the raws of fins and affected by fin pitches. At the rear face of fin, there exists minimum point of heat transfer coefficients where stream are separated from the fin surfaces. The convective heat transfer coefficients were effected by separation bubbies which appeared at the wake region of offset strip fins.

막온도 변화를 고려한 가는 열선주위 나노유체의 대류열전달계수 측정 실험 (Measuring Convective Heat Transfer Coefficient of Nanofluids Considering Effect of Film Temperature Change over Heated Fine Wire)

  • 이신표
    • 대한기계학회논문집B
    • /
    • 제37권8호
    • /
    • pp.725-732
    • /
    • 2013
  • 본 논문에서는 가는 열선 주위를 흐르는 나노유체의 대류열전달 특성을 실험을 통하여 검토하였다. 입자 혼합 농도가 다른 4개의 나노엔진오일에 대하여 열선온도가 증가하는 경우, 유체온도가 증가하는 경우 그리고 막온도가 일정하게 유지되는 경우 등 세가지 온도경계조건에 대하여 대류열전달계수를 측정하였다. 내부유동에서 나노유체의 대류열전달계수 상승이 열전도율 상승을 초과한다는 결과가 최근 발표되기도 했지만 본 연구에서는 이 결과를 확인할 수 없었다. 온도조건에 따른 대류열전달계수의 변화 거동을 분석함으로써 나노유체의 열전도율과 경계층두께의 관계를 설명할 수 있었다.

Prediction of Forced Convective Boiling Heat Transfer Coefficient of Pure Refrigerants and Binary Refrigerant Mixtures Inside a Horizontal Tube

  • Kim, Min-Soo;Hong, Eul-Cheong;Shin, Jee-Young;Kyungdoug Min;Ro, Sung-Tack
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.935-944
    • /
    • 2003
  • Forced convective boiling heat transfer coefficients were predicted for an annular flow inside a horizontal tube for pure refrigerants and nonazeotropic binary refrigerant mixtures. The heat transfer coefficients were calculated based on the turbulent temperature profile in liquid film and vapor core considering the composition difference in vapor and liquid phases, and the nonlinearity in mixing rules for the calculation of mixture properties. The heat transfer coefficients of pure refrigerants were estimated within a standard deviation of 14% compared with available experimental data. For nonazeotropic binary refrigerant mixtures, prediction of the heat transfer coefficients was made with a standard deviation of 18%. The heat transfer coefficients of refrigerant mixtures were lower than linearly interpolated values calculated from the heat transfer coefficients of pure refrigerants. This degradation was represented by several factors such as the difference between the liquid and the overall compositions, the conductivity ratio and the viscosity ratio of both components in refrigerant mixtures. The temperature change due to the concentration gradient was a major factor for the heat transfer degradation and the mass flux itself at the interface had a minor effect.

순수 및 혼합냉매의 유동증발 열전달 상관식 (Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures)

  • 신지영;김민수;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석 (Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process)

  • 서효민;박병흥
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.123-133
    • /
    • 2023
  • 상용 수소연료전지 차량은 기체 수소를 고압으로 압축하여 차량 내 저장 탱크로 저장하는 방식으로 충전이 진행된다. 이러한 압축 과정은 기체의 온도 상승을 유발하며, 저장 탱크의 안전성을 확보하기 위해 온도는 제한된다. 따라서 이러한 온도 상승을 설명하기 위한 열전달 모델이 필요하다. 열전달 모델은 대류 열전달 현상을 포함하며 정확한 대류 열전달 계수 추산이 요구된다. 본 연구에서는 수소 충전 과정에서의 대류 열전달 계수를 물리적 현상을 고려한 다양한 상관관계식을 이용하여 계산하고 비교 분석하였다. 수소 충전 과정은 디스펜서로부터 탱크 입구까지의 충전라인과 차량 내 저장 탱크로 분류하였고, 각각의 내부 및 외부에서의 대류 열전달 계수를 질량 유량, 직경, 온도와 압력 등 공정 변수에 따라 추산하였다. 그 결과, 충전라인 내부의 경우 저장 탱크 내부에서보다 대류 열전달 계수가 약 1000배 크게 나타났고, 충전라인 외부의 경우 저장 탱크 외부에서보다 대류 열전달 계수가 약 3배 크게 나타났다. 마지막으로 각 과정에서의 대류 열전달 계수를 종합 분석한 결과 전체 수소 충전 과정에서 저장 탱크 외부에서의 열전달 계수가 가장 낮아 열전달 현상을 지배하는 것으로 나타났다.

옵셋 스트립 휜에서 오일유동의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Oil Flow over Offset Strip Fins)

  • 양대일;정형호
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1134-1140
    • /
    • 2001
  • In the present study, heat transfer characteristics of oil flow over offset strip fins were predicted by the numerical methods. Oil flow in the plate-fin passage was idealized by 2 dimension. Power law scheme and SIMPLE algorithm were used for convective diffusion formulation and pressure term respectively. Governing equations were discretized by control volume formulation. The flow patterns and heat transfer were predicted in details. The convective heat transfer coefficients were affected by separation bubbles which appeared at the wake region of offset strip fins.

  • PDF

입구경계층 두께와 경계층 펜스가 터빈 캐스케이드내 열전달 특서에 미치는 영향 (Effects of the Inlet Boundary Layer Thickness and the Boundary Layer Fence on the Heat Transfer Chracteristics in a Turbine Cascade)

  • 정지선;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.765-770
    • /
    • 2001
  • The objective of the present study is to investigate the effects of the various inlet boundary layer thickness on convective heat transfer distribution in a turbine cascade endwall and blade suction surface. In addition, the proper height of the boundary layer fences for various inlet boundary layer thickness were applied to turbine cascade endwall in order to reduce the secondary flow, and to verify its influence on the heat transfer process within the turbine cascade. Convective heat transfer distributions on the experimental regions were measured by the image processing system. The results show that heat transfer coefficients on the blade suction surface were increased with an augmentation of inlet boundary layer thickness. However, in a turbine cascade endwall, magnitude of heat transfer coefficients did not change with variation of inlet boundary layer thickness. The results also present that the boundary layer fence is effective in reducing heat transfer on the suction surface. On the other hand, in the endwall region, boundary layer fence brought about the subsidiary heat transfer increment.

  • PDF