Prediction of Forced Convective Boiling Heat Transfer Coefficient of Pure Refrigerants and Binary Refrigerant Mixtures Inside a Horizontal Tube

  • Kim, Min-Soo (School of Mechanical and Aerospace Engineering, Seoul National University) ;
  • Hong, Eul-Cheong (School of Mechanical and Aerospace Engineering, Seoul National University) ;
  • Shin, Jee-Young (Department of Mechanical Engineering, Dong-Eui University) ;
  • Kyungdoug Min (School of Mechanical and Aerospace Engineering, Seoul National University) ;
  • Ro, Sung-Tack (School of Mechanical and Aerospace Engineering, Seoul National University)
  • Published : 2003.06.01

Abstract

Forced convective boiling heat transfer coefficients were predicted for an annular flow inside a horizontal tube for pure refrigerants and nonazeotropic binary refrigerant mixtures. The heat transfer coefficients were calculated based on the turbulent temperature profile in liquid film and vapor core considering the composition difference in vapor and liquid phases, and the nonlinearity in mixing rules for the calculation of mixture properties. The heat transfer coefficients of pure refrigerants were estimated within a standard deviation of 14% compared with available experimental data. For nonazeotropic binary refrigerant mixtures, prediction of the heat transfer coefficients was made with a standard deviation of 18%. The heat transfer coefficients of refrigerant mixtures were lower than linearly interpolated values calculated from the heat transfer coefficients of pure refrigerants. This degradation was represented by several factors such as the difference between the liquid and the overall compositions, the conductivity ratio and the viscosity ratio of both components in refrigerant mixtures. The temperature change due to the concentration gradient was a major factor for the heat transfer degradation and the mass flux itself at the interface had a minor effect.

Keywords

References

  1. Butterworth, D. and Hewitt. G. F., 1977, Two phase Flow and Heat Transfer, 1st ed. Oxford University Press
  2. Collier, J. G. and Thome, J. R., 1994, Convective Boiling and Condensation, 3rd ed. McGraw-Hill
  3. Didion, D. A. and Bivens, D. B., 1990, 'Role of Refrigerant Mixtures as Altenatives to CFCs,' Int. J. Refrig., Vol. 13, pp. 163-175 https://doi.org/10.1016/0140-7007(90)90071-4
  4. Domanski, P. A. and Didion, D. A., 1993, 'Thermodynamic Evaluation of R-22 Alternative Refrigerants and Refrigerant Mixtures,' ASHRAE Trans., Vol. 99, Part 2
  5. Gill, L. E., Hewiitt, G. F. and Lacey, P. M. C., 1964, 'Sampling Probe Studies of the Gas Core in Annular Two Phase Flow: Ⅱ,Studies of the Effect of Phase Flow Rates on Phase and Velocity Distribution,' Chem. Eng. Sci., Vol. 19, pp. 665-682 https://doi.org/10.1016/0009-2509(64)85054-5
  6. Hashizume, K., Ogiwara, H. and Taniguchi, H., 1985, 'Flow Pattern, Void Fraction and Pressure Drop of Refrigerant Two-phase Flow in a Horizontal Pipe-Ⅰ:Analysis of Frictional Pressure Drop,' Int. J. Multiphase Flow, Vol. 11, pp. 643-658 https://doi.org/10.1016/0301-9322(85)90084-9
  7. Hihara, E., Tanida, K. and Saito, T., 1989, 'Forced Convective Boiling Experiments of Binary Mixtures,' Int. J. JSME, Vol. 32, pp. 98-106
  8. Hong, E. C., Kim, M. S. and Ro. S. T., 1995, 'Prediction of Evaporative Heat Transfer Coefficient of Pure Refrigerants and Binary Refrigerant Mixtures in a Horizontal Tube,' Proc. of the 19th International Congress of Refrigeration, Ausust 20-25, The Hague, The Netherlands, Vol. IVa, pp. 313-320
  9. Jung, D. S., McLinden, M., Radermacher, R. and Didion, D. A., 1989, 'Horizontal Flow Boiling Heat Transfer Experiments with Mixture of R22/R114,' Int. J. Heat Mass Transfer, Vol. 32, pp. 131-145 https://doi.org/10.1016/0017-9310(89)90097-5
  10. Kays, W. M. and Crawford, M. E., 1993, Convective Heat and Mass Transfer, 3rd ed. McGraw Hill, Ch. 11
  11. Kedzierski, M. A., Kim, J. H. and Didion, D. A., 1992, 'Causes of the Apparent Heat Transfer Degradation for Refrigerant Mixtures,' ASME HTD Two-Phase Flow and Heat Transfer, Vol. 197, pp. 149-158
  12. Kruse, H., 1981, 'The Advantages of Non-azeotropic Refigerant Mixtures for Heat Pump Application,' Int. J. Refrig., Vol. 4, pp. 119-125 https://doi.org/10.1016/0140-7007(81)90102-X
  13. Murata, K. and Hashizume, K., 1993, 'Forced Convective Boiling of Nonazeotropic Refrigerant Mixtures Inside Tube,' J. Heat Transfer, Vol. 115, pp. 680-689 https://doi.org/10.1115/1.2910739
  14. Price, B. C. and Bell, K. J., 1974, 'Design of Binary Vapor Condensers Using the Colburn-Drew Equations,' AIChE Symp. Series, Vol. 70, No. 138, pp. 163-171
  15. Reid, R. C., Prausnitz, C. A. and Poling, B. E., 1987, The Properties of Gases and Liquids, 4th ed. McGraw Hill
  16. Ross, H., Radermacher, R., Di Marzo, M. and Didion, D. A., 1987, 'Horizontal Flow Boiling of Pure and Mixed Refrigerants,' Int. J. Heat Mass Transfer, Vol. 30, pp. 979-992 https://doi.org/10.1016/0017-9310(87)90016-0
  17. Shin, J. Y., Kim, M. S. and Ro, S. T., 1997, 'Experimental Study on Forced Convective Boiling Heat Transfer of Pure Refrigerants and Refrigerant Mixtures in a Horizontal Tube,' Int. J. Refrig., Vol. 20, No. 4, pp. 267-275 https://doi.org/10.1016/S0140-7007(97)00004-2