An Improvement of Transient Stability of Multi-machine Power System (다기계통의 과도 안정도 향상)

  • Kim, Soo-Nam;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.911-913
    • /
    • 1997
  • This paper presents a method for optima] placement of series capacitors in order to improve the power system transient stability, using genetic algorithms. For the formulation, this paper considers the objective function which is the energy margin as the difference between transient energy and critical energy. The most important factor in determining an accurate critical energy is the controlling unstable equilibrium point (UEP). This paper proposes the controlling UEP methods, concurrently with the DFP(Davidon-Fletcher-Powell) method, which enables the enhancement of multi-machine analysis. The proposed method is applied to 6-bus, 7-line, 4-machine model system to show its effectiveness in determining the locations to install series capacitors and the it's size to be installed in system, simultaneously.

  • PDF

A Study on Heat Transfer Characteristics of H-120 Class Fire Damper for Offshore Structures (해양플랜트용 H-120급 방화 댐퍼의 열전달 특성에 관한 연구)

  • Jang, Sung-Cheol;Lee, Jong-Hwan;Lee, Chi-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.19-24
    • /
    • 2014
  • This research conducts CAE analysis of fire damper and design of damper controlling system. The prediction of the design heat transfer was done the answer of fire damper could be obtained by using continuity equation of damper controlling and orthogonal array. Through the design analysis of optimal offshore construction, new fire damper of H-120 class was designed. Accordingly, this equipment will be tested in actual offshore construction. Finally, we could obtain fire damper of optimal design with orthogonal array. With the CAE results of this research, The offshore plant will obtain eco-friendly fire damper with a method to select optimal condition of fire damper with orthogonal array.

Performance Evaluation and Technical Development of Eco-environmental Photovoltaic Leisure Ship with Sail-controlling Device With Respect to Solar-Hybrid Generating System (풍력 Sail 돛 제어장치를 이용한 친환경 태양광 레져보트의 하이브리드 발전시스템 관련 성능평가에 대한 연구)

  • Oh, Kyoung Gun;Moon, Byung Young;Lee, Ki Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2016
  • As a new technical approach, an attempt was made to realize a photovoltaic system for an eco-environmental leisure ship by simultaneously actuating nine photovoltaic solar panels in association with the application of a sail-controlling system using wind energy. In this approach, the photovoltaic system consisted of a solar module, an inverter, a battery, and the relevant components, while the sail-controlling device was equipped with sail up/down and mast turning systems. The previously mentioned eco-environmental leisure ship utilizes a photovoltaic hybrid system that uses solar and wind energy as renewable energy sources. Furthermore, this research included a performance evaluation of the manufactured prototype, the acquisition of the purposed quantity values, and development of the purposed items. The significant items, including the sail up/down speed (seconds) and mast turning angle (degrees) were evaluated for a performance test. A wind direction sensitivity of 90% and maximum instant charging power of 900 W were also obtained in the process of the performance evaluation. In addition, the maximum sail time was also evaluated in order to acquire the optimum value. The performance evaluation showed that the prototype with a photovoltaic hybrid system was suitable for sailing an eco-environmental leisure ship using solar and wind energy.

Voltage Source HVDC System Controller Design (전압형 HVDC 시스템 제어기설계)

  • 곽주식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.645-650
    • /
    • 2000
  • this paper deals with HVDC Light(High Voltage Direct Current) system using space vector PWM(SVPWM) method. Because the system of this paper has d-q control scheme for HVDC Light system. HVDC Light system represented in this paper is capable of controlling active and reactive power independently. For this system. V-I curve and control methods are proposed. Also this paper describes the design of a digital system for applications in power converters such as those that would be used in the next generation of HVDC system. Finally HVDC system is implemented using DSP TMS320C31

  • PDF

The Parallel Operation of Single Phase PWM Rectifier using IGBT (IGBT를 이용한 단산 PWM정류기 병렬운전)

  • 이현원;장성영;김연준;이광주;김남해
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.122-125
    • /
    • 1999
  • The AC-to-DC single-phase PWM rectifier for traction applications using high power semiconductor, IGCT is made and tested. Parallel operation of two PWM converter is adopted for increasing capacity of converters. For reducing harmonics, the harmonic content is eliminated by the phase shift between two converters switching phase. The output voltage control is achieved by interns calculation without detecting the input current. The part of PLL used for controlling power factor is simply implemented by software.

  • PDF

Low-Power Decimation Filter Using Approximate Processing with Control of Error in CSD Representation (CSD 표현의 오차를 이용한 Approximate Processing과 이를 이용한 저전력 Decimation Filter의 설계)

  • 양영모;김영우;김수원
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.236-239
    • /
    • 1999
  • This paper describes a low-power design of decimation filter. To reduce power consumption, an approximate processing method which controls the error in canonic signed digit(CSD) coefficients is proposed. The CSD representation reduces the number of operations by representing multiplications with add and shift operations. The proposed method further reduces the number of operations by controlling the error of CSD coefficient. Processor type architecture is used to implement the proposed method. Simulation result shows that the number of operations is reduced to 56%, 35% and 10% at each approximated filter level.

  • PDF

A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement (전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구)

  • 손진근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

Generalized Vector Control with Reactive Power Control for Brushless Doubly-Fed Induction Machines

  • Duan, Qiwei;Liu, Shi;Schlaberg, H. Inaki;Long, Teng
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.817-825
    • /
    • 2018
  • In this paper, a current hysteresis control with good decoupling properties for doubly-fed brushless induction machines (BDFIMs) has been proposed based on a generalized vector model. The independent control of the reactive power and speed for BDFIMs has been achieved by controlling the d-axis and the q-axis current of the control windings (CW). The proposed vector control method has been developed for the power winding (PW) flux frame. Experimental verification of a type Y180M-4 BDFIM prototype with 1/4 pole-pairs has been presented. Evidence of its good performance has been shown through experimental results.

Omni-directional Mobile Robot for 2D Translation and Rotation of a Puppet using Magnet (줄 인형의 2차원 이동 및 회전을 위한 자석기반 전 방향 로봇시스템)

  • Kim, Byeong-Yeol;Han, Young-Jun;Hahn, Hun-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.326-331
    • /
    • 2010
  • Marionette controlling robot has a problem that generates interference in rotation and intersection, therefore, the research on the independent shifter to move freely on the stage is required. Connecting omni-directional mobile robot with marionette controlling robot can solve this problem. Omni-directional mobile robot makes itself rotate and translate in 2D plane freely. Magnetic device is used to connect the moving part with the control part of the robot to minimize the intereference generated by the movement of robot. When robot moves, it can move to all directions with the suitalbe setting of banlance power. The moment of inertia is minimized by dividing the robot to the upper and lower parts in the marionette performance stage. Rotation and interference problem of independent omni-wheel Robot can be solved by using the permanent magnet. The efficiency and safety of the marionette controlling robot is proved by the experiment.

A Study on Safety for Computer Based Railway Signaling Control System (컴퓨터기반 철도신호제어시스템의 안전성 확보에 관한 연구)

  • SHIN Ducko;LEE Jongwoo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.641-646
    • /
    • 2004
  • Computer system is widely used for controlling systems such as nuclear power plant, train speed control and air plane control. The failure of computerized controlling system can be arrived to catastrophic accident, so the safety ensuring of computerized controlling system is very important. This paper shows how to improve and ensure the safety of computerized systems. In this paper, we show how to identify, analyze hazards of the computerized system and to demonstrate risk of the system. Finally, we show how to adopt safety techniques for improving safety of the target system.