• 제목/요약/키워드: Controlling Power

검색결과 1,245건 처리시간 0.027초

FACTS 기기를 이용한 전력시스템의 안전도 향상 (The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS))

  • 송성환;임정욱;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

Performance of MIMO-OFDMA system combining power controlling algorithm with multi-beamformer

  • Kim, Chan Kyu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.69-78
    • /
    • 2022
  • In this paper, we propose the new technique adopting power control to MIMO(multi-input multi-output)-OFDMA(orthogonal frequency division multiplexing Access) system with multi-beamformer. The proposed power controlling algorithm for MIMO-OFDMA allocates the transmitting power of each subcarrier based on the CSI(channel state information) and the interference signal. CSI is feedback from base station to mobile station to decide the transmitting power of each subcarrier. Through the proposed technique, we can control iteratively the transmitting power and update the weight of beamformer simultaneously. Therefore, the SNIR of each subcarrier become to converge the target SNIR and the beam is formed toward the desired direction. And the performance of MIMO-OFDMA system with the proposed approach is very improved. The improvement in bit error rate is investigated through computer simulation of a MIMO-OFDMA system with the proposed approach.

Capacitively Coupled Plasma Source를 이용한 Etcher의 상부 전극 온도 변화에 따른 Etch 특성 변화 개선 (Improvement of Repeatability during Dielectric Etching by Controlling Upper Electrode Temperature)

  • 신한수;노용한;이내응
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.322-326
    • /
    • 2011
  • 상부 전극에 RF power 가 직접 인가되는 capacitively coupled plasma source를 이용한 oxide layer etching 공정은 현재 반도체 제조 공정에서 매우 유용하게 사용되고 있는 방식이다. 그러나 디바이스의 사이즈가 점점 작아지면서 공정을 진행하기 위한 RF power도 커지고, plasma ignition 되는 electrode 사이의 간격도 점점 좁아지는 기술적 변화가 이루어지고 있다. 이러한 H/W의 변화에 따라 예상치 못한 문제들로 공정을 적용하는데 많은 문제점이 발생하고 있는데, 공정 진행 시에 plasma의 영향으로 인한 electrode의 온도 변화도 그 중 하나이다. 이러한 온도 변화로 인해 wafer to wafer의 공정 진행 결과가 서로 다르게 나타나게 하는 문제가 야기되고 있다. 아래의 내용에서는 상부 electrode의 온도 변화에 따른 etch 특성을 연구하고, 이를 개선할 수 있는 방법에 대해 논하고자 한다.

차량 속도 기반 정확도 제어를 통한 차량용 LiDAR 센서의 효율적 전력 절감 기법 (Efficient Power Reduction Technique of LiDAR Sensor for Controlling Detection Accuracy Based on Vehicle Speed)

  • 이상훈;이동규;최평;박대진
    • 대한임베디드공학회논문지
    • /
    • 제15권5호
    • /
    • pp.215-225
    • /
    • 2020
  • Light detection and ranging (LiDAR) sensors detect the distance of the surrounding environment and objects. Conventional LiDAR sensors require a certain amount of a power because they detect objects by transmitting lasers at a regular interval depending on a constant resolution. The constant power consumption from operating multiple LiDAR sensors is detrimental to autonomous and electric vehicles using battery power. In this paper, we propose two algorithms that improve the inefficient power consumption during the constant operation of LiDAR sensors. LiDAR sensors with algorithms efficiently reduce the power consumption in two ways: (a) controlling the resolution to vary the laser transmission period (TP) of a laser diode (LD) depending on the vehicle's speed and (b) reducing the static power consumption using a sleep mode depending on the surrounding environment. A proposed LiDAR sensor with a resolution control algorithm reduces the power consumption of the LD by 6.92% to 32.43% depending on the vehicle's speed, compared to the maximum number of laser transmissions (Nx·max). The sleep mode with a surrounding environment-sensing algorithm reduces the power consumption by 61.09%. The proposed LiDAR sensor has a risk factor for 4-cycles that does not detect objects in the sleep mode, but we consider it to be negligible because it immediately switches to an active mode when a change in surrounding conditions occurs. The proposed LiDAR sensor was tested on a commercial processor chip with the algorithm controlling the resolution according to the vehicle's speed and the surrounding environment.

3-레벨 컨버터에 의한 직류전력제어 (DC Power Control for 3-Level Converter.)

  • 정연택;이사영;함년근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.126-129
    • /
    • 1996
  • This paper study on the control method of 3-level converter. The control of converter is composed of active power control for controlling a output voltage and of reactive power control for high power factor drives. And also, output central voltage is controlled by sensing a each condensor voltage of bank connected the part of dc.

  • PDF

발전소 운전 중 증기터빈 밸브 시험 방식 소개 (An Introduction to Test Methods about Steam Valves of Steam Turbines in Power Plants)

  • 최인규;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1601-1602
    • /
    • 2007
  • Steam stop valves of steam turbine in the power plant are at their 100% position and have no movements. Steam control valves, ie governor valves have no movements either at their controlling position on load limit operation. By the way, if there were no change of operation state, steam valves could be sticked mechanically. Because the governor could fail in protecting and controlling steam turbine in case of emergency conditions, the closing test of 100% valve travel must be accomplished periodically for the purpose of testimony of their good conditions. And, As the difference between steam turbine structures exists according to the manufacturer or generation capacity, both steam stop valves and steam control valves differes in structure and operation method. Therefore, it is essential for not only turbine protection but also control for the control engineers to find out composition of steam valves and method of closing test.

  • PDF

프랙탑 현상을 이용한 과도 안정도 해석 (Transient Stability Analysis Using Fractal Behaviours)

  • 최종윤;안현식;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1103-1105
    • /
    • 1997
  • Transient stability analysis is concerned with a power system's response to unwanted disturbance. Recently, direct method which utilize the stable region of stable equilibrium point is used to analyze transient stability This paper focuses on the controlling UEP method using the fractal behaviours. In the controlling UEP method, many algorithms are used to find controlling UEP However, the existence of fractal region gives difficulty in finding the controlling UEP. So, this paper observes the fractal feature arid introduce the fractal index to explain how much the fractal region occupies in the entire space. Using an improved algorithm from the view point of fractal index, we are going to find the controlling UEP.

  • PDF

A Dynamic Frequency Controlling Technique for Power Management in Existing Commercial Microcontrollers

  • Lueangvilai, Attakorn;Robertson, Christina;Martinez, Christopher J.
    • Journal of Computing Science and Engineering
    • /
    • 제6권2호
    • /
    • pp.79-88
    • /
    • 2012
  • Power continues to be a driving force in central processing units (CPU) design. Most of the advanced breakthroughs in power have been in a realm that is applicable to workstation CPUs. Advanced power management systems will manage temperature, dynamic voltage scaling and dynamic frequency scaling in a CPU. The use of power management systems for microcontrollers and embedded CPUs has been modest, and mostly focuses on very large scale integration (VLSI) level optimizations compared to system level optimizations. In this paper, a dynamic frequency controlling (DFC) technique is introduced, to lay the foundation of a system level power management system for commercial microcontrollers. The DFC technique allows a commercial microcontroller to have minor modifications on both the hardware and software side, to allow the clock frequency to change to save power; results in this study show a 10% savings. By adding an additional layer of software abstraction at the interrupt level, the microcontroller can operate without having knowledge of the current clock frequency, and this can be accomplished without having to use an embedded operating system.

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

구난장갑차 동력인출장치의 오일조절용 어댑터 개발 (A Study on the Oil-Controlling Adapter of Power Take-Off for Armored Recovery Vehicles)

  • 박경철;신헌용;이창희
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.46-50
    • /
    • 2016
  • When rotating the clutch drum in the power take-off (PTO) gear box of an armored recovery vehicle, lots of inner oil is drained through the adapter by centrifugal force. Therefore, a lack of lubrication is caused by inner oil loss, and the bearing is damaged by overheating. This study, therefore, aims to design an oil-controlling adapter by using shape alteration to prevent oil loss. Both the original and improved adapters were tested at 1,800rpm by using an operational test machine. When applying the original adapter to the gear box, the bearing was damaged by overheating, which was caused by the lack of lubrication. When applying the improved oil-controlling adapter, on the other hand, it prevented the loss of inner oil. Applying the improved adapter is expected to prevent the overheating caused by lack of lubrication.