Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2007.07a
- /
- Pages.1601-1602
- /
- 2007
An Introduction to Test Methods about Steam Valves of Steam Turbines in Power Plants
발전소 운전 중 증기터빈 밸브 시험 방식 소개
- Choi, In-Kyu (Korea Electric Power Research Institute) ;
- Woo, Joo-Hee (Korea Electric Power Research Institute)
- Published : 2007.07.18
Abstract
Steam stop valves of steam turbine in the power plant are at their 100% position and have no movements. Steam control valves, ie governor valves have no movements either at their controlling position on load limit operation. By the way, if there were no change of operation state, steam valves could be sticked mechanically. Because the governor could fail in protecting and controlling steam turbine in case of emergency conditions, the closing test of 100% valve travel must be accomplished periodically for the purpose of testimony of their good conditions. And, As the difference between steam turbine structures exists according to the manufacturer or generation capacity, both steam stop valves and steam control valves differes in structure and operation method. Therefore, it is essential for not only turbine protection but also control for the control engineers to find out composition of steam valves and method of closing test.